{"title":"手术室电磁场强度评价及人员职业暴露评估。","authors":"Karim Ghazikhanlou-Sani,&nbsp;Azizollah Rahimi,&nbsp;Maryam Poorkaveh,&nbsp;Samira Eynali,&nbsp;Fereshteh Koosha,&nbsp;Mohsen Shoja","doi":"10.1556/1646.10.2018.18","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Operating rooms in hospitals are facilitated with different types of electronic systems, which produce electromagnetic waves. High intensities of magnetic waves may have harmful effects on biological environments. This study aims to evaluate the electromagnetic field intensity at different parts of operating rooms at the first stage and estimate the occupational exposure to operating room personnel at the next phase.</p><p><strong>Materials and methods: </strong>At this cross-sectional study, the magnetic field intensity was evaluated using teslameter at several parts of operating rooms, during operating procedures, while electrical instruments were working. Background electromagnetic field intensity was measured when all the electrical systems were idle. Statistical analysis was performed using SPSS software. The results were compared with ICNIRP standards.</p><p><strong>Results: </strong>The maximum intensity of magnetic field was measured around high-voltage systems at the distance of 50 cm in the personnel's standing area at DCR and PCNL operating procedures were 5.9 and 5.6, respectively. The number of on-mode electrical systems was inconsistent with the intensity of electromagnetic fields at the standing area of operating room personnel's. The intensity of magnetic fields around high-voltage systems, which was about 46.75 mG at the distance of 10 cm, was the highest among measured electromagnetic fields.</p><p><strong>Conclusions: </strong>The highest magnetic field intensity measured in this study was related to high-voltage systems and is lower than advised intensity by ICNIRP for occupational exposure. Based on this study, it can be concluded that there are no considerable risks of electromagnetic exposure for operating room personnels.</p>","PeriodicalId":45181,"journal":{"name":"Interventional Medicine and Applied Science","volume":"10 3","pages":"121-126"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1556/1646.10.2018.18","citationCount":"2","resultStr":"{\"title\":\"Evaluation of the electromagnetic field intensity in operating rooms and estimation of occupational exposures of personnel.\",\"authors\":\"Karim Ghazikhanlou-Sani,&nbsp;Azizollah Rahimi,&nbsp;Maryam Poorkaveh,&nbsp;Samira Eynali,&nbsp;Fereshteh Koosha,&nbsp;Mohsen Shoja\",\"doi\":\"10.1556/1646.10.2018.18\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Operating rooms in hospitals are facilitated with different types of electronic systems, which produce electromagnetic waves. High intensities of magnetic waves may have harmful effects on biological environments. This study aims to evaluate the electromagnetic field intensity at different parts of operating rooms at the first stage and estimate the occupational exposure to operating room personnel at the next phase.</p><p><strong>Materials and methods: </strong>At this cross-sectional study, the magnetic field intensity was evaluated using teslameter at several parts of operating rooms, during operating procedures, while electrical instruments were working. Background electromagnetic field intensity was measured when all the electrical systems were idle. Statistical analysis was performed using SPSS software. The results were compared with ICNIRP standards.</p><p><strong>Results: </strong>The maximum intensity of magnetic field was measured around high-voltage systems at the distance of 50 cm in the personnel's standing area at DCR and PCNL operating procedures were 5.9 and 5.6, respectively. The number of on-mode electrical systems was inconsistent with the intensity of electromagnetic fields at the standing area of operating room personnel's. The intensity of magnetic fields around high-voltage systems, which was about 46.75 mG at the distance of 10 cm, was the highest among measured electromagnetic fields.</p><p><strong>Conclusions: </strong>The highest magnetic field intensity measured in this study was related to high-voltage systems and is lower than advised intensity by ICNIRP for occupational exposure. Based on this study, it can be concluded that there are no considerable risks of electromagnetic exposure for operating room personnels.</p>\",\"PeriodicalId\":45181,\"journal\":{\"name\":\"Interventional Medicine and Applied Science\",\"volume\":\"10 3\",\"pages\":\"121-126\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1556/1646.10.2018.18\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Interventional Medicine and Applied Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1556/1646.10.2018.18\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Medicine and Applied Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1556/1646.10.2018.18","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 2

摘要

导言:医院的手术室都有不同类型的电子系统,这些系统会产生电磁波。高强度的电磁波可能对生物环境产生有害影响。本研究旨在评估第一阶段手术室不同部位的电磁场强度,并评估下一阶段手术室人员的职业暴露。材料和方法:在本横断面研究中,在手术过程中,当电气仪器工作时,在手术室的几个部分使用teslameter评估磁场强度。在所有电气系统处于空闲状态时测量背景电磁场强度。采用SPSS软件进行统计分析。结果与ICNIRP标准进行比较。结果:在DCR和PCNL操作程序中,测得高压系统周围人员站立区50 cm处的最大磁场强度分别为5.9和5.6。导通电气系统数量与手术室人员站立区电磁场强度不一致。在测得的电磁场中,高压系统周围的磁场强度最高,约为46.75 mG,距离为10 cm。结论:本研究测量的最高磁场强度与高压系统有关,低于ICNIRP建议的职业暴露强度。基于本研究,可以得出结论,手术室人员不存在相当大的电磁暴露风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of the electromagnetic field intensity in operating rooms and estimation of occupational exposures of personnel.

Introduction: Operating rooms in hospitals are facilitated with different types of electronic systems, which produce electromagnetic waves. High intensities of magnetic waves may have harmful effects on biological environments. This study aims to evaluate the electromagnetic field intensity at different parts of operating rooms at the first stage and estimate the occupational exposure to operating room personnel at the next phase.

Materials and methods: At this cross-sectional study, the magnetic field intensity was evaluated using teslameter at several parts of operating rooms, during operating procedures, while electrical instruments were working. Background electromagnetic field intensity was measured when all the electrical systems were idle. Statistical analysis was performed using SPSS software. The results were compared with ICNIRP standards.

Results: The maximum intensity of magnetic field was measured around high-voltage systems at the distance of 50 cm in the personnel's standing area at DCR and PCNL operating procedures were 5.9 and 5.6, respectively. The number of on-mode electrical systems was inconsistent with the intensity of electromagnetic fields at the standing area of operating room personnel's. The intensity of magnetic fields around high-voltage systems, which was about 46.75 mG at the distance of 10 cm, was the highest among measured electromagnetic fields.

Conclusions: The highest magnetic field intensity measured in this study was related to high-voltage systems and is lower than advised intensity by ICNIRP for occupational exposure. Based on this study, it can be concluded that there are no considerable risks of electromagnetic exposure for operating room personnels.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Interventional Medicine and Applied Science
Interventional Medicine and Applied Science MEDICINE, GENERAL & INTERNAL-
CiteScore
1.60
自引率
0.00%
发文量
0
审稿时长
15 weeks
期刊最新文献
Plasma interleukin-6 levels correlate with survival in patients with bacterial sepsis and septic shock. Levels of glucagon-like peptide 1 in hyperemesis gravidarum. ln vitro inhibition of beta-hematin formation and in vivo effects of Diospyros mespiliformis and Mondia whitei methanol extracts on chloroquine-susceptible Plasmodium berghei-induced malaria in mice. Pulsation of catheter during coronary angiography: Is it a sign of severe aortic regurgitation? Efficacy, safety and tolerability of bosentan as an adjuvant to sildenafil and sildenafil alone in persistant pulmonary hypertension of newborn (PPHN).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1