{"title":"液滴数字聚合酶链反应法绝对定量甲型流感病毒。","authors":"Zhaomin Feng, Xiang Zhao, Xiaohui Zou, Wenfei Zhu, Yongkun Chen, Dayan Wang, Yuelong Shu","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Digital polymerase chain reaction (dPCR) is a new method for absolute quantification. However, an absolute quantification method for influenza A viruses based on droplet digital polymerase chain reaction (dPCR) has not been established. In this study, we found that: (i) the annealing temperature of dPCR was optimized at 64, 4°C; (ii) the detection range of dPCR was 37.7 approximately 8.22 X 10(4) copies/μl for influenza A viruses; (iii) the limit of detection of dPCR was 3. 77 copies/reaction. The liner correlation coefficient (R(2)) was found to be 0. 9988, suggesting the high reliability of our dPCR method. The dPCR method could be used to detect influenza A viruses clinically. In summary, we developed a dPCR method for absolute quantification of influenza A viruses. This method could be used effectively to quantify influenza A viruses in clinical samples. Therefore, our method could be a new tool for the absolute quantification of viral load.</p>","PeriodicalId":8776,"journal":{"name":"Bing du xue bao = Chinese journal of virology","volume":"33 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Droplet Digital Polymerase Chain Reaction Method for Absolute Quantification of Influenza A Viruses.\",\"authors\":\"Zhaomin Feng, Xiang Zhao, Xiaohui Zou, Wenfei Zhu, Yongkun Chen, Dayan Wang, Yuelong Shu\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Digital polymerase chain reaction (dPCR) is a new method for absolute quantification. However, an absolute quantification method for influenza A viruses based on droplet digital polymerase chain reaction (dPCR) has not been established. In this study, we found that: (i) the annealing temperature of dPCR was optimized at 64, 4°C; (ii) the detection range of dPCR was 37.7 approximately 8.22 X 10(4) copies/μl for influenza A viruses; (iii) the limit of detection of dPCR was 3. 77 copies/reaction. The liner correlation coefficient (R(2)) was found to be 0. 9988, suggesting the high reliability of our dPCR method. The dPCR method could be used to detect influenza A viruses clinically. In summary, we developed a dPCR method for absolute quantification of influenza A viruses. This method could be used effectively to quantify influenza A viruses in clinical samples. Therefore, our method could be a new tool for the absolute quantification of viral load.</p>\",\"PeriodicalId\":8776,\"journal\":{\"name\":\"Bing du xue bao = Chinese journal of virology\",\"volume\":\"33 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bing du xue bao = Chinese journal of virology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bing du xue bao = Chinese journal of virology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Droplet Digital Polymerase Chain Reaction Method for Absolute Quantification of Influenza A Viruses.
Digital polymerase chain reaction (dPCR) is a new method for absolute quantification. However, an absolute quantification method for influenza A viruses based on droplet digital polymerase chain reaction (dPCR) has not been established. In this study, we found that: (i) the annealing temperature of dPCR was optimized at 64, 4°C; (ii) the detection range of dPCR was 37.7 approximately 8.22 X 10(4) copies/μl for influenza A viruses; (iii) the limit of detection of dPCR was 3. 77 copies/reaction. The liner correlation coefficient (R(2)) was found to be 0. 9988, suggesting the high reliability of our dPCR method. The dPCR method could be used to detect influenza A viruses clinically. In summary, we developed a dPCR method for absolute quantification of influenza A viruses. This method could be used effectively to quantify influenza A viruses in clinical samples. Therefore, our method could be a new tool for the absolute quantification of viral load.