[我中心活体肾移植候选者肾功能评价调查]。

Koichi Kozaki
{"title":"[我中心活体肾移植候选者肾功能评价调查]。","authors":"Koichi Kozaki","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In Japan, the number of living renal transplant donors with medical complications has been increasing in recent years due to the.aging of donors. It is important to assess donor renal function properly before donation to ensure donor safety. This study aimed to assess different renal function measures of donors, includ- ing serum creatinine (Cr), creatinine clearance (Ccr), estimated glomerular filtration rate (eGFR), and inulin clearance (Cin). The mean Cr and eGFR values of 64 donors before surgery and at 1 month, 1 year, and 3 years after surgery were 0.74, 1.15, 1.13, and 1.05 mg/dL, respectively, and 71.7, 42.4, 44.9, and 49.5 mL/min/1.73m2, respectively. Values of eGFR 3 years after surgery in 20 out of 36 donors (55.6%) were less than 50 mL/min/1.73m2, showing that moderately decreased levels of GFR persist for a long time after donation. The preoperative renal function of 20 candidate donors was evaluated based on Cr, Ccr, eGFR, and Cin. The mean preoperative values were Cr 0.74 mg/dL, eGFR 71.9 mL/min/1.73m2, Ccr 137.3 mL/min, and Cin 92.9 mL/min. Ccr overestimated Cin in 18 out of 20 donors (90%) and eGFR underestimated Cin in 16 donors (80%). Cin measurements are complicated, which can lead to human errors in measurement. Conversely, eGFR measurements are simple but are inferior to Cin in terms of accuracy; therefore, the pre- operative renal function of donors should be evaluated by Cin, combined with other tests as much as possible to ensure a safe living renal transplant. [Original].</p>","PeriodicalId":21457,"journal":{"name":"Rinsho byori. The Japanese journal of clinical pathology","volume":"64 12","pages":"1341-1346"},"PeriodicalIF":0.0000,"publicationDate":"2016-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Investigation of the Renal Function Evaluation in the Living Donor Renal Transplantation Candidate at Our Center].\",\"authors\":\"Koichi Kozaki\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In Japan, the number of living renal transplant donors with medical complications has been increasing in recent years due to the.aging of donors. It is important to assess donor renal function properly before donation to ensure donor safety. This study aimed to assess different renal function measures of donors, includ- ing serum creatinine (Cr), creatinine clearance (Ccr), estimated glomerular filtration rate (eGFR), and inulin clearance (Cin). The mean Cr and eGFR values of 64 donors before surgery and at 1 month, 1 year, and 3 years after surgery were 0.74, 1.15, 1.13, and 1.05 mg/dL, respectively, and 71.7, 42.4, 44.9, and 49.5 mL/min/1.73m2, respectively. Values of eGFR 3 years after surgery in 20 out of 36 donors (55.6%) were less than 50 mL/min/1.73m2, showing that moderately decreased levels of GFR persist for a long time after donation. The preoperative renal function of 20 candidate donors was evaluated based on Cr, Ccr, eGFR, and Cin. The mean preoperative values were Cr 0.74 mg/dL, eGFR 71.9 mL/min/1.73m2, Ccr 137.3 mL/min, and Cin 92.9 mL/min. Ccr overestimated Cin in 18 out of 20 donors (90%) and eGFR underestimated Cin in 16 donors (80%). Cin measurements are complicated, which can lead to human errors in measurement. Conversely, eGFR measurements are simple but are inferior to Cin in terms of accuracy; therefore, the pre- operative renal function of donors should be evaluated by Cin, combined with other tests as much as possible to ensure a safe living renal transplant. [Original].</p>\",\"PeriodicalId\":21457,\"journal\":{\"name\":\"Rinsho byori. The Japanese journal of clinical pathology\",\"volume\":\"64 12\",\"pages\":\"1341-1346\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Rinsho byori. The Japanese journal of clinical pathology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rinsho byori. The Japanese journal of clinical pathology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在日本,近年来有医疗并发症的活体肾移植供体的数量一直在增加。捐赠者老龄化。捐献前正确评估供者肾功能,确保供者安全是很重要的。本研究旨在评估供者的不同肾功能指标,包括血清肌酐(Cr)、肌酐清除率(Ccr)、估计肾小球滤过率(eGFR)和菊粉清除率(Cin)。64例供者术前、术后1个月、1年、3年Cr、eGFR均值分别为0.74、1.15、1.13、1.05 mg/dL, 71.7、42.4、44.9、49.5 mL/min/1.73m2。36例献血者中有20例(55.6%)术后3年eGFR值小于50 mL/min/1.73m2,表明捐献后GFR中度下降持续时间较长。根据Cr、Ccr、eGFR和Cin评估20例候选供者的术前肾功能。术前平均值Cr为0.74 mg/dL, eGFR为71.9 mL/min/1.73m2, Ccr为137.3 mL/min, Cin为92.9 mL/min。20名献血者中,Ccr高估了18名(90%),eGFR低估了16名(80%)。中国的测量是复杂的,这可能导致人为误差的测量。相反,eGFR测量简单,但在准确性方面不如中国;因此,术前应对供者进行肾功能评估,并尽可能结合其他检查,以确保安全的活体肾移植。(最初的)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Investigation of the Renal Function Evaluation in the Living Donor Renal Transplantation Candidate at Our Center].

In Japan, the number of living renal transplant donors with medical complications has been increasing in recent years due to the.aging of donors. It is important to assess donor renal function properly before donation to ensure donor safety. This study aimed to assess different renal function measures of donors, includ- ing serum creatinine (Cr), creatinine clearance (Ccr), estimated glomerular filtration rate (eGFR), and inulin clearance (Cin). The mean Cr and eGFR values of 64 donors before surgery and at 1 month, 1 year, and 3 years after surgery were 0.74, 1.15, 1.13, and 1.05 mg/dL, respectively, and 71.7, 42.4, 44.9, and 49.5 mL/min/1.73m2, respectively. Values of eGFR 3 years after surgery in 20 out of 36 donors (55.6%) were less than 50 mL/min/1.73m2, showing that moderately decreased levels of GFR persist for a long time after donation. The preoperative renal function of 20 candidate donors was evaluated based on Cr, Ccr, eGFR, and Cin. The mean preoperative values were Cr 0.74 mg/dL, eGFR 71.9 mL/min/1.73m2, Ccr 137.3 mL/min, and Cin 92.9 mL/min. Ccr overestimated Cin in 18 out of 20 donors (90%) and eGFR underestimated Cin in 16 donors (80%). Cin measurements are complicated, which can lead to human errors in measurement. Conversely, eGFR measurements are simple but are inferior to Cin in terms of accuracy; therefore, the pre- operative renal function of donors should be evaluated by Cin, combined with other tests as much as possible to ensure a safe living renal transplant. [Original].

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Candida]. [Bleeding time]. [Microparticle]. [Aldolase]. [Telomerase].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1