有限元分析中种植体长度及相关参数对生物力学力的影响:系统综述。

3区 医学 Q1 Dentistry Implant Dentistry Pub Date : 2019-06-01 DOI:10.1097/ID.0000000000000879
Lukas Hingsammer, Bernhard Pommer, Stefan Hunger, Rapahel Stehrer, Georg Watzek, Angel Insua
{"title":"有限元分析中种植体长度及相关参数对生物力学力的影响:系统综述。","authors":"Lukas Hingsammer,&nbsp;Bernhard Pommer,&nbsp;Stefan Hunger,&nbsp;Rapahel Stehrer,&nbsp;Georg Watzek,&nbsp;Angel Insua","doi":"10.1097/ID.0000000000000879","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this systematic review is to provide an overview of finite element analyses comparing standard and short dental implants concerning biomechanical properties and to detect the most relevant parameters affecting periimplant stress concentrations.</p><p><strong>Material and methods: </strong>After screening the literature and assessment of studies, 36 studies were included in this review.</p><p><strong>Results: </strong>Eighty-three percent of the studies state that short dental implants have to bear higher stress concentrations compared with standard length implants. At the same time, 44% of articles note that implant diameter can be considered a more effective design parameter than implant length to reduce stress concentrations and to avoid an overload of periimplant bone. Regardless of implant dimension, in all studies, the highest stress concentrations are found in the cortical section around the upper part of the implant.</p><p><strong>Conclusions: </strong>Unaffected of bone quality, implant diameter is found to play a key role to minimize periimplant stress concentrations. Concerning stress reduction implant length gains increasing relevance with decreasing bone density. Furthermore, splinting of short implants constitute an appropriate tool to avoid crestal overloading.</p>","PeriodicalId":13309,"journal":{"name":"Implant Dentistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/ID.0000000000000879","citationCount":"14","resultStr":"{\"title\":\"Influence of Implant Length and Associated Parameters Upon Biomechanical Forces in Finite Element Analyses: A Systematic Review.\",\"authors\":\"Lukas Hingsammer,&nbsp;Bernhard Pommer,&nbsp;Stefan Hunger,&nbsp;Rapahel Stehrer,&nbsp;Georg Watzek,&nbsp;Angel Insua\",\"doi\":\"10.1097/ID.0000000000000879\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The aim of this systematic review is to provide an overview of finite element analyses comparing standard and short dental implants concerning biomechanical properties and to detect the most relevant parameters affecting periimplant stress concentrations.</p><p><strong>Material and methods: </strong>After screening the literature and assessment of studies, 36 studies were included in this review.</p><p><strong>Results: </strong>Eighty-three percent of the studies state that short dental implants have to bear higher stress concentrations compared with standard length implants. At the same time, 44% of articles note that implant diameter can be considered a more effective design parameter than implant length to reduce stress concentrations and to avoid an overload of periimplant bone. Regardless of implant dimension, in all studies, the highest stress concentrations are found in the cortical section around the upper part of the implant.</p><p><strong>Conclusions: </strong>Unaffected of bone quality, implant diameter is found to play a key role to minimize periimplant stress concentrations. Concerning stress reduction implant length gains increasing relevance with decreasing bone density. Furthermore, splinting of short implants constitute an appropriate tool to avoid crestal overloading.</p>\",\"PeriodicalId\":13309,\"journal\":{\"name\":\"Implant Dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1097/ID.0000000000000879\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Implant Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/ID.0000000000000879\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Implant Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ID.0000000000000879","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 14

摘要

目的:本系统综述的目的是提供比较标准和短牙种植体有关生物力学性能的有限元分析的概述,并检测影响种植周应力浓度的最相关参数。材料和方法:经过文献筛选和研究评价,本综述共纳入36项研究。结果:83%的研究表明,与标准长度种植体相比,短种植体必须承受更高的应力浓度。同时,44%的文章指出,种植体直径可以被认为是比种植体长度更有效的设计参数,以减少应力集中并避免种植体周围骨超载。无论种植体的尺寸如何,在所有的研究中,在种植体上部周围的皮质部分发现了最高的应力浓度。结论:种植体直径不受骨质量的影响,在减少种植体周围应力集中方面起着关键作用。关于应力降低,种植体长度与骨密度的降低越来越相关。此外,短种植体的夹板是避免牙冠超载的适当工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Influence of Implant Length and Associated Parameters Upon Biomechanical Forces in Finite Element Analyses: A Systematic Review.

Purpose: The aim of this systematic review is to provide an overview of finite element analyses comparing standard and short dental implants concerning biomechanical properties and to detect the most relevant parameters affecting periimplant stress concentrations.

Material and methods: After screening the literature and assessment of studies, 36 studies were included in this review.

Results: Eighty-three percent of the studies state that short dental implants have to bear higher stress concentrations compared with standard length implants. At the same time, 44% of articles note that implant diameter can be considered a more effective design parameter than implant length to reduce stress concentrations and to avoid an overload of periimplant bone. Regardless of implant dimension, in all studies, the highest stress concentrations are found in the cortical section around the upper part of the implant.

Conclusions: Unaffected of bone quality, implant diameter is found to play a key role to minimize periimplant stress concentrations. Concerning stress reduction implant length gains increasing relevance with decreasing bone density. Furthermore, splinting of short implants constitute an appropriate tool to avoid crestal overloading.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Implant Dentistry
Implant Dentistry 医学-牙科与口腔外科
CiteScore
4.00
自引率
0.00%
发文量
0
审稿时长
6-12 weeks
期刊介绍: Cessation. Implant Dentistry, an interdisciplinary forum for general practitioners, specialists, educators, and researchers, publishes relevant clinical, educational, and research articles that document current concepts of oral implantology in sections on biomaterials, clinical reports, oral and maxillofacial surgery, oral pathology, periodontics, prosthodontics, and research. The journal includes guest editorials, letters to the editor, book reviews, abstracts of current literature, and news of sponsoring societies.
期刊最新文献
The Editorial Council Implant. Comparison Between a Computer-Aided Surgical Template and the Free-Hand Method: A Systematic Review and Meta-Analysis. Long-Term Outcomes of Tooth-Implant-Supported Rehabilitation of Periodontally Compromised and Treated Patients Refusing Bone Grafting Surgical Therapies. Ridge Augmentation Comparing an Allograft Plus Autogenous Bone Chips to an Osteoinductive Demineralized Bone Matrix: A Clinical and Histologic Study in Humans.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1