快速部署主动脉瓣植入术后血小板计数下降。

André Sena, Ricardo Ferreira, Mariana Nobre, Hugo Ferreira, Nádia Junqueira, Tiago Velho, Joana Silva, João Gonçalves, Nuno Guerra, Ricardo Pereira, Ângelo Nobre
{"title":"快速部署主动脉瓣植入术后血小板计数下降。","authors":"André Sena,&nbsp;Ricardo Ferreira,&nbsp;Mariana Nobre,&nbsp;Hugo Ferreira,&nbsp;Nádia Junqueira,&nbsp;Tiago Velho,&nbsp;Joana Silva,&nbsp;João Gonçalves,&nbsp;Nuno Guerra,&nbsp;Ricardo Pereira,&nbsp;Ângelo Nobre","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>A transient postoperative drop in platelet count is an expected finding after aortic valve replacement using extracorporeal circulation. The implantation of the Perceval valve has been associated with a more intense drop of platelet count compared to other bio-prostheses. This study analyses and compares the platelets progression associated with the Perceval and Intuity valves.</p><p><strong>Methods: </strong>The data was collected retrospectively for patients submitted to isolated aortic valve replacement with the Perceval valve (80 patients) and the Intuity valve (141 patients) in our institution between March 2014 and December 2018. The groups were further divided into those who receive platelet transfusion and those who did not.</p><p><strong>Results: </strong>The minimum values of platelet count were 54% and 67% of the preoperative platelet count in the patients treated with a Perceval and an Intuity valves, respectively (p<0.001). In the patients transfused with platelets, the minimum values were 52% and 79% of the preoperative platelet count, respectively (p<0.01). Recovery of the count was faster in the patients treated with an Intuity valve. Abnormal bleeding and transfusion of packed red blood cells were not significantly different between groups (without platelet transfusion: p=0.71 and p=0.99, respectively; with platelet transfusion: p=0.58 and p=0.99, respectively).</p><p><strong>Conclusion: </strong>Compared to the Intuity valve, the Perceval valve is associated with a transient, but significant, drop in platelet count. This drop was not associated to an increased risk of bleeding. Platelet transfusion, in this setting, should be judicious and not only ruled by absolute values.</p>","PeriodicalId":87136,"journal":{"name":"Revista portuguesa de cirurgia cardio-toracica e vascular : orgao oficial da Sociedade Portuguesa de Cirurgia Cardio-Toracica e Vascular","volume":"27 2","pages":"91-96"},"PeriodicalIF":0.0000,"publicationDate":"2020-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Platelet Count Drop After Rapid Deployment Aortic Valve Implantation.\",\"authors\":\"André Sena,&nbsp;Ricardo Ferreira,&nbsp;Mariana Nobre,&nbsp;Hugo Ferreira,&nbsp;Nádia Junqueira,&nbsp;Tiago Velho,&nbsp;Joana Silva,&nbsp;João Gonçalves,&nbsp;Nuno Guerra,&nbsp;Ricardo Pereira,&nbsp;Ângelo Nobre\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>A transient postoperative drop in platelet count is an expected finding after aortic valve replacement using extracorporeal circulation. The implantation of the Perceval valve has been associated with a more intense drop of platelet count compared to other bio-prostheses. This study analyses and compares the platelets progression associated with the Perceval and Intuity valves.</p><p><strong>Methods: </strong>The data was collected retrospectively for patients submitted to isolated aortic valve replacement with the Perceval valve (80 patients) and the Intuity valve (141 patients) in our institution between March 2014 and December 2018. The groups were further divided into those who receive platelet transfusion and those who did not.</p><p><strong>Results: </strong>The minimum values of platelet count were 54% and 67% of the preoperative platelet count in the patients treated with a Perceval and an Intuity valves, respectively (p<0.001). In the patients transfused with platelets, the minimum values were 52% and 79% of the preoperative platelet count, respectively (p<0.01). Recovery of the count was faster in the patients treated with an Intuity valve. Abnormal bleeding and transfusion of packed red blood cells were not significantly different between groups (without platelet transfusion: p=0.71 and p=0.99, respectively; with platelet transfusion: p=0.58 and p=0.99, respectively).</p><p><strong>Conclusion: </strong>Compared to the Intuity valve, the Perceval valve is associated with a transient, but significant, drop in platelet count. This drop was not associated to an increased risk of bleeding. Platelet transfusion, in this setting, should be judicious and not only ruled by absolute values.</p>\",\"PeriodicalId\":87136,\"journal\":{\"name\":\"Revista portuguesa de cirurgia cardio-toracica e vascular : orgao oficial da Sociedade Portuguesa de Cirurgia Cardio-Toracica e Vascular\",\"volume\":\"27 2\",\"pages\":\"91-96\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista portuguesa de cirurgia cardio-toracica e vascular : orgao oficial da Sociedade Portuguesa de Cirurgia Cardio-Toracica e Vascular\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista portuguesa de cirurgia cardio-toracica e vascular : orgao oficial da Sociedade Portuguesa de Cirurgia Cardio-Toracica e Vascular","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:体外循环主动脉瓣置换术后血小板计数出现短暂性下降是意料之中的。与其他生物假体相比,Perceval瓣膜的植入与血小板计数的急剧下降有关。本研究分析并比较了与Perceval和Intuity瓣膜相关的血小板进展。方法:回顾性收集我院2014年3月至2018年12月间采用Perceval瓣膜置换术(80例)和Intuity瓣膜置换术(141例)的主动脉瓣置换术患者的资料。这些小组进一步分为接受血小板输注和未接受血小板输注的两组。结果:使用Perceval和Intuity瓣膜治疗的患者血小板计数的最小值分别为术前血小板计数的54%和67%(结论:与Intuity瓣膜相比,Perceval瓣膜与短暂但显著的血小板计数下降有关。这种下降与出血风险增加无关。在这种情况下,输血小板应该是明智的,而不仅仅是由绝对值决定的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Platelet Count Drop After Rapid Deployment Aortic Valve Implantation.

Background: A transient postoperative drop in platelet count is an expected finding after aortic valve replacement using extracorporeal circulation. The implantation of the Perceval valve has been associated with a more intense drop of platelet count compared to other bio-prostheses. This study analyses and compares the platelets progression associated with the Perceval and Intuity valves.

Methods: The data was collected retrospectively for patients submitted to isolated aortic valve replacement with the Perceval valve (80 patients) and the Intuity valve (141 patients) in our institution between March 2014 and December 2018. The groups were further divided into those who receive platelet transfusion and those who did not.

Results: The minimum values of platelet count were 54% and 67% of the preoperative platelet count in the patients treated with a Perceval and an Intuity valves, respectively (p<0.001). In the patients transfused with platelets, the minimum values were 52% and 79% of the preoperative platelet count, respectively (p<0.01). Recovery of the count was faster in the patients treated with an Intuity valve. Abnormal bleeding and transfusion of packed red blood cells were not significantly different between groups (without platelet transfusion: p=0.71 and p=0.99, respectively; with platelet transfusion: p=0.58 and p=0.99, respectively).

Conclusion: Compared to the Intuity valve, the Perceval valve is associated with a transient, but significant, drop in platelet count. This drop was not associated to an increased risk of bleeding. Platelet transfusion, in this setting, should be judicious and not only ruled by absolute values.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Meeting Abstracts of the SPCCTV 4D Visions 20, 28-29 November 2020, Figueira da Foz, Portugal. Multiple Vs Single Arterial Grafting In Coronary Surgery Among Diabetic Patients: A Meta-Analysis. Fibromuscular Dysplasia Of The Renal Arteries. Why And When To Request For A Pet/Ct Scan In A Lung Cancer Patient?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1