{"title":"使用针式微压计测量组织内肿胀压力的方法。","authors":"C M Krull, A D Lutton, J W Olesik, B A Walter","doi":"10.22203/eCM.v040a09","DOIUrl":null,"url":null,"abstract":"<p><p>The intervertebral disc's ability to resist load and facilitate motion arises largely from osmotic swelling pressures that develop within the tissue. Changes in the disc's osmotic environment, diurnally and with disease, have been suggested to regulate cellular activity, yet knowledge of in vivo osmotic environments is limited. Therefore, the first objective of this study was to demonstrate proof-of-concept for a method to measure intra-tissue swelling pressure and osmolality, modeling micro-osmometer fluid flux using Darcy's law. The second objective was to compare flux-based measurements of the swelling pressure within nucleus pulposus (NP) tissue against ionic swelling pressures predicted by Gibbs-Donnan theory. Pressures (0.03- 0.57 MPa) were applied to NP tissue (n = 25) using equilibrium dialysis, and intra-tissue swelling pressures were measured using flux. Ionic swelling pressures were determined from inductively coupled plasma optical emission spectrometry measurements of intra-tissue sodium using Gibbs-Donnan calculations of fixed charge density and intra-tissue chloride. Concordance of 0.93 was observed between applied pressures and flux- based measurements of swelling pressure. Equilibrium bounds for effective tissue osmolalities engendered by a simulated diurnal loading cycle (0.2-0.6 MPa) were 376 and 522 mOsm/kg H2O. Significant differences between flux and Gibbs-Donnan measures of swelling pressure indicated that total tissue water normalization and non-ionic contributions to swelling pressure were significant, which suggested that standard constitutive models may underestimate intra-tissue swelling pressure. Overall, this micro-osmometer technique may facilitate future validations for constitutive models and measurements of variation in the diurnal osmotic cycle, which may inform studies to identify diurnal- and disease-associated changes in mechanotransduction.</p>","PeriodicalId":11849,"journal":{"name":"European cells & materials","volume":"40 ","pages":"146-159"},"PeriodicalIF":3.2000,"publicationDate":"2020-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/09/bf/nihms-1646624.PMC8653509.pdf","citationCount":"0","resultStr":"{\"title\":\"A method for measuring intra-tissue swelling pressure using a needle micro-osmometer.\",\"authors\":\"C M Krull, A D Lutton, J W Olesik, B A Walter\",\"doi\":\"10.22203/eCM.v040a09\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The intervertebral disc's ability to resist load and facilitate motion arises largely from osmotic swelling pressures that develop within the tissue. Changes in the disc's osmotic environment, diurnally and with disease, have been suggested to regulate cellular activity, yet knowledge of in vivo osmotic environments is limited. Therefore, the first objective of this study was to demonstrate proof-of-concept for a method to measure intra-tissue swelling pressure and osmolality, modeling micro-osmometer fluid flux using Darcy's law. The second objective was to compare flux-based measurements of the swelling pressure within nucleus pulposus (NP) tissue against ionic swelling pressures predicted by Gibbs-Donnan theory. Pressures (0.03- 0.57 MPa) were applied to NP tissue (n = 25) using equilibrium dialysis, and intra-tissue swelling pressures were measured using flux. Ionic swelling pressures were determined from inductively coupled plasma optical emission spectrometry measurements of intra-tissue sodium using Gibbs-Donnan calculations of fixed charge density and intra-tissue chloride. Concordance of 0.93 was observed between applied pressures and flux- based measurements of swelling pressure. Equilibrium bounds for effective tissue osmolalities engendered by a simulated diurnal loading cycle (0.2-0.6 MPa) were 376 and 522 mOsm/kg H2O. Significant differences between flux and Gibbs-Donnan measures of swelling pressure indicated that total tissue water normalization and non-ionic contributions to swelling pressure were significant, which suggested that standard constitutive models may underestimate intra-tissue swelling pressure. Overall, this micro-osmometer technique may facilitate future validations for constitutive models and measurements of variation in the diurnal osmotic cycle, which may inform studies to identify diurnal- and disease-associated changes in mechanotransduction.</p>\",\"PeriodicalId\":11849,\"journal\":{\"name\":\"European cells & materials\",\"volume\":\"40 \",\"pages\":\"146-159\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2020-09-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/09/bf/nihms-1646624.PMC8653509.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European cells & materials\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.22203/eCM.v040a09\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CELL & TISSUE ENGINEERING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European cells & materials","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.22203/eCM.v040a09","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CELL & TISSUE ENGINEERING","Score":null,"Total":0}
A method for measuring intra-tissue swelling pressure using a needle micro-osmometer.
The intervertebral disc's ability to resist load and facilitate motion arises largely from osmotic swelling pressures that develop within the tissue. Changes in the disc's osmotic environment, diurnally and with disease, have been suggested to regulate cellular activity, yet knowledge of in vivo osmotic environments is limited. Therefore, the first objective of this study was to demonstrate proof-of-concept for a method to measure intra-tissue swelling pressure and osmolality, modeling micro-osmometer fluid flux using Darcy's law. The second objective was to compare flux-based measurements of the swelling pressure within nucleus pulposus (NP) tissue against ionic swelling pressures predicted by Gibbs-Donnan theory. Pressures (0.03- 0.57 MPa) were applied to NP tissue (n = 25) using equilibrium dialysis, and intra-tissue swelling pressures were measured using flux. Ionic swelling pressures were determined from inductively coupled plasma optical emission spectrometry measurements of intra-tissue sodium using Gibbs-Donnan calculations of fixed charge density and intra-tissue chloride. Concordance of 0.93 was observed between applied pressures and flux- based measurements of swelling pressure. Equilibrium bounds for effective tissue osmolalities engendered by a simulated diurnal loading cycle (0.2-0.6 MPa) were 376 and 522 mOsm/kg H2O. Significant differences between flux and Gibbs-Donnan measures of swelling pressure indicated that total tissue water normalization and non-ionic contributions to swelling pressure were significant, which suggested that standard constitutive models may underestimate intra-tissue swelling pressure. Overall, this micro-osmometer technique may facilitate future validations for constitutive models and measurements of variation in the diurnal osmotic cycle, which may inform studies to identify diurnal- and disease-associated changes in mechanotransduction.
期刊介绍:
eCM provides an interdisciplinary forum for publication of preclinical research in the musculoskeletal field (Trauma, Maxillofacial (including dental), Spine and Orthopaedics).
The clinical relevance of the work must be briefly mentioned within the abstract, and in more detail in the paper. Poor abstracts which do not concisely cover the paper contents will not be sent for review. Incremental steps in research will not be entertained by eCM journal.Cross-disciplinary papers that go across our scope areas are welcomed.