意外植入人工耳蜗儿童胆脂瘤作为人工耳蜗植入的晚期并发症。

IF 0.4 Q4 OTORHINOLARYNGOLOGY Case Reports in Otolaryngology Pub Date : 2020-10-09 eCollection Date: 2020-01-01 DOI:10.1155/2020/6353706
Wong Kein Low, Wan Ni Pok, Win Nie Ng, Judy Tan
{"title":"意外植入人工耳蜗儿童胆脂瘤作为人工耳蜗植入的晚期并发症。","authors":"Wong Kein Low,&nbsp;Wan Ni Pok,&nbsp;Win Nie Ng,&nbsp;Judy Tan","doi":"10.1155/2020/6353706","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Although rare, cholesteatoma can develop as a late complication of cochlear implantation. The electrode array may then be exposed in the external auditory canal surrounded by cholesteatoma debris. <i>Case Report</i>. The cochlear implant of a child was inadvertently explanted by a clinician during a routine aural toilet procedure. The child had previously reported recurrent ear infections, pain, and unexplained implant function degradation. Reimplantation was carried out 2 days later with good postoperative hearing results. Part of the electrode array was observed to be embedded in cholesteatoma. Postreimplantation recovery was complicated by a breakdown of the blind-sac. <i>Discussion</i>. Clinical indicators that could alert the clinician to the possibility of this late complication include recurrent infections, presence of keratotic debris in the external auditory canal, unexplained implant function degradation, and nonauditory stimulation. Although this patient managed to achieve excellent postreimplantation hearing outcomes, a delay in reimplantation surgery following explantation could possibly compromise successful reinsertion of the electrode array. External ear canal overclosure without mastoid cavity obliteration has merit in facilitating CT scan surveillance, but it may increase the risk of the blind-sac breaking down. This case also illustrated how the electrode array could have facilitated propagation of the cholesteatoma from the middle ear to the mastoid.</p><p><strong>Conclusion: </strong>If aural toilet is required in the implanted ear of a cochlear implant recipient, any complaint of hearing change, pain, or discharge should alert the clinician of the possibility of cholesteatoma developing. It warrants prompt evaluation by an experienced otologist in order to prevent accidental explantation. <i>Keywords</i>. Cochlear implant, cochlear implant complications, chronic suppurative otitis media, cholesteatoma, reimplantation, blind-sac, external auditory canal overclosure, mastoid cavity obliteration.</p>","PeriodicalId":45872,"journal":{"name":"Case Reports in Otolaryngology","volume":"2020 ","pages":"6353706"},"PeriodicalIF":0.4000,"publicationDate":"2020-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2020/6353706","citationCount":"1","resultStr":"{\"title\":\"Accidental Explantation of a Cochlear Implant in a Child Who Developed Cholesteatoma as a Late Complication of Cochlear Implantation.\",\"authors\":\"Wong Kein Low,&nbsp;Wan Ni Pok,&nbsp;Win Nie Ng,&nbsp;Judy Tan\",\"doi\":\"10.1155/2020/6353706\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Although rare, cholesteatoma can develop as a late complication of cochlear implantation. The electrode array may then be exposed in the external auditory canal surrounded by cholesteatoma debris. <i>Case Report</i>. The cochlear implant of a child was inadvertently explanted by a clinician during a routine aural toilet procedure. The child had previously reported recurrent ear infections, pain, and unexplained implant function degradation. Reimplantation was carried out 2 days later with good postoperative hearing results. Part of the electrode array was observed to be embedded in cholesteatoma. Postreimplantation recovery was complicated by a breakdown of the blind-sac. <i>Discussion</i>. Clinical indicators that could alert the clinician to the possibility of this late complication include recurrent infections, presence of keratotic debris in the external auditory canal, unexplained implant function degradation, and nonauditory stimulation. Although this patient managed to achieve excellent postreimplantation hearing outcomes, a delay in reimplantation surgery following explantation could possibly compromise successful reinsertion of the electrode array. External ear canal overclosure without mastoid cavity obliteration has merit in facilitating CT scan surveillance, but it may increase the risk of the blind-sac breaking down. This case also illustrated how the electrode array could have facilitated propagation of the cholesteatoma from the middle ear to the mastoid.</p><p><strong>Conclusion: </strong>If aural toilet is required in the implanted ear of a cochlear implant recipient, any complaint of hearing change, pain, or discharge should alert the clinician of the possibility of cholesteatoma developing. It warrants prompt evaluation by an experienced otologist in order to prevent accidental explantation. <i>Keywords</i>. Cochlear implant, cochlear implant complications, chronic suppurative otitis media, cholesteatoma, reimplantation, blind-sac, external auditory canal overclosure, mastoid cavity obliteration.</p>\",\"PeriodicalId\":45872,\"journal\":{\"name\":\"Case Reports in Otolaryngology\",\"volume\":\"2020 \",\"pages\":\"6353706\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2020-10-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/2020/6353706\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Case Reports in Otolaryngology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2020/6353706\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2020/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"OTORHINOLARYNGOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Case Reports in Otolaryngology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2020/6353706","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 1

摘要

简介:胆脂瘤虽罕见,但可发展为人工耳蜗植入的晚期并发症。电极阵列可以暴露在被胆脂瘤碎片包围的外耳道中。病例报告。一个孩子的人工耳蜗在一次常规的听觉厕所手术中被临床医生无意中取出。该患儿此前曾报告耳部反复感染、疼痛和不明原因的植入物功能退化。术后2 d再植,术后听力良好。观察到部分电极阵列嵌埋在胆脂瘤中。术后恢复因盲囊破裂而变得复杂。讨论。临床指标可提醒临床医生注意这种晚期并发症的可能性,包括反复感染、外耳道存在角化碎片、不明原因的植入物功能退化和非听觉刺激。尽管该患者在植入术后获得了良好的听力效果,但植入术后再植入术的延迟可能会影响电极阵列的成功再植入术。不封堵乳突腔的外耳道过闭有利于CT扫描监测,但可能增加盲囊破裂的风险。这个病例也说明了电极阵列如何促进胆脂瘤从中耳到乳突的扩散。结论:如果人工耳蜗受者的植入耳内需要使用耳屎,任何有关听力改变、疼痛或分泌物的抱怨都应提醒临床医生注意发生胆脂瘤的可能性。它保证由经验丰富的耳科医生及时评估,以防止意外外植。关键词。人工耳蜗、人工耳蜗并发症、慢性化脓性中耳炎、胆脂瘤、人工耳蜗再植、盲囊、外耳道过闭、乳突腔闭塞。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Accidental Explantation of a Cochlear Implant in a Child Who Developed Cholesteatoma as a Late Complication of Cochlear Implantation.

Introduction: Although rare, cholesteatoma can develop as a late complication of cochlear implantation. The electrode array may then be exposed in the external auditory canal surrounded by cholesteatoma debris. Case Report. The cochlear implant of a child was inadvertently explanted by a clinician during a routine aural toilet procedure. The child had previously reported recurrent ear infections, pain, and unexplained implant function degradation. Reimplantation was carried out 2 days later with good postoperative hearing results. Part of the electrode array was observed to be embedded in cholesteatoma. Postreimplantation recovery was complicated by a breakdown of the blind-sac. Discussion. Clinical indicators that could alert the clinician to the possibility of this late complication include recurrent infections, presence of keratotic debris in the external auditory canal, unexplained implant function degradation, and nonauditory stimulation. Although this patient managed to achieve excellent postreimplantation hearing outcomes, a delay in reimplantation surgery following explantation could possibly compromise successful reinsertion of the electrode array. External ear canal overclosure without mastoid cavity obliteration has merit in facilitating CT scan surveillance, but it may increase the risk of the blind-sac breaking down. This case also illustrated how the electrode array could have facilitated propagation of the cholesteatoma from the middle ear to the mastoid.

Conclusion: If aural toilet is required in the implanted ear of a cochlear implant recipient, any complaint of hearing change, pain, or discharge should alert the clinician of the possibility of cholesteatoma developing. It warrants prompt evaluation by an experienced otologist in order to prevent accidental explantation. Keywords. Cochlear implant, cochlear implant complications, chronic suppurative otitis media, cholesteatoma, reimplantation, blind-sac, external auditory canal overclosure, mastoid cavity obliteration.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Case Reports in Otolaryngology
Case Reports in Otolaryngology OTORHINOLARYNGOLOGY-
自引率
0.00%
发文量
20
审稿时长
13 weeks
期刊最新文献
Schwannoma at an Unusual Site: Case Report and Surgical Technique Discussion for Nasal Dorsum. Lemierre Syndrome with Extensive Thrombosis: A Unique Case Report and Literature Review. New Instruments for the Management of Cochlear Implantation in an Individual with a Fracture of the Temporal Bone and Cochlear Ossification. Ectopic Salivary Gland Found in the Vocal Cord: A Rare Case. Pleomorphic Adenoma of the Palate: Diagnostic and Surgical Strategy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1