{"title":"双能CT非线性图像融合技术对孤立性肺结节分子特征的影响。","authors":"Qian Li, Huan Tan, Furong Lv","doi":"10.1080/10799893.2020.1853158","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To investigate the feasibility and to optimize the parameters of nonlinear blending technique in dual-energy CT on solitary pulmonary nodules (SPN).</p><p><strong>Methods: </strong>The simulated enhanced SPN were used the mixture of nonionic iodinated contrast agent (Iopromide 370mgI/100 ml) and normal saline and then randomly placed inside an anthropomorphic chest phantom. The phantom was examined on SOMATOM definition flash with dual mode (80/140 kV) and single energy mode (120 kV) (the same CTDIvol). Nonlinear blending images and linear blending images with a weighting factor of 0.3 were generated and the image qualities were analyzed.</p><p><strong>Results: </strong>For different simulated density SPN, when 0 HU was chosen as the Blending Center (BC) and 0 to 30 HU were chosen as the Blending width (BW), the nonlinear blending images yielded a higher contrast-to-noise (CNR). There were significant differences in the image noise and signal-to-noise (SNR) of different simulated density SPN at non-linear blending images, linear blending images and 120 kV images (<i>p</i> < .05); But the differences of CNR between the three groups were not statistically significant (<i>p</i> > .05). The SNR of different simulated density SPN at non-linear blending images was significantly increased compared with it at linear blending images and 120 kV images (<i>p</i> < .05); And the image noise at non-linear blending was lower than it at linear blending images (<i>p</i> < .05).</p><p><strong>Conclusion: </strong>Nonlinear blending technique in dual-energy CT can increase the SNR of enhanced SPN, and it is helpful in diagnosis of SPN.</p>","PeriodicalId":16962,"journal":{"name":"Journal of Receptors and Signal Transduction","volume":"42 1","pages":"95-99"},"PeriodicalIF":2.6000,"publicationDate":"2022-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/10799893.2020.1853158","citationCount":"5","resultStr":"{\"title\":\"Molecular characterization of solitary pulmonary nodules in dual-energy CT nonlinear image fusion technology.\",\"authors\":\"Qian Li, Huan Tan, Furong Lv\",\"doi\":\"10.1080/10799893.2020.1853158\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To investigate the feasibility and to optimize the parameters of nonlinear blending technique in dual-energy CT on solitary pulmonary nodules (SPN).</p><p><strong>Methods: </strong>The simulated enhanced SPN were used the mixture of nonionic iodinated contrast agent (Iopromide 370mgI/100 ml) and normal saline and then randomly placed inside an anthropomorphic chest phantom. The phantom was examined on SOMATOM definition flash with dual mode (80/140 kV) and single energy mode (120 kV) (the same CTDIvol). Nonlinear blending images and linear blending images with a weighting factor of 0.3 were generated and the image qualities were analyzed.</p><p><strong>Results: </strong>For different simulated density SPN, when 0 HU was chosen as the Blending Center (BC) and 0 to 30 HU were chosen as the Blending width (BW), the nonlinear blending images yielded a higher contrast-to-noise (CNR). There were significant differences in the image noise and signal-to-noise (SNR) of different simulated density SPN at non-linear blending images, linear blending images and 120 kV images (<i>p</i> < .05); But the differences of CNR between the three groups were not statistically significant (<i>p</i> > .05). The SNR of different simulated density SPN at non-linear blending images was significantly increased compared with it at linear blending images and 120 kV images (<i>p</i> < .05); And the image noise at non-linear blending was lower than it at linear blending images (<i>p</i> < .05).</p><p><strong>Conclusion: </strong>Nonlinear blending technique in dual-energy CT can increase the SNR of enhanced SPN, and it is helpful in diagnosis of SPN.</p>\",\"PeriodicalId\":16962,\"journal\":{\"name\":\"Journal of Receptors and Signal Transduction\",\"volume\":\"42 1\",\"pages\":\"95-99\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2022-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/10799893.2020.1853158\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Receptors and Signal Transduction\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://doi.org/10.1080/10799893.2020.1853158\",\"RegionNum\":4,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2020/11/30 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"BIOCHEMISTRY & MOLECULAR BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Receptors and Signal Transduction","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1080/10799893.2020.1853158","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/11/30 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
Molecular characterization of solitary pulmonary nodules in dual-energy CT nonlinear image fusion technology.
Objective: To investigate the feasibility and to optimize the parameters of nonlinear blending technique in dual-energy CT on solitary pulmonary nodules (SPN).
Methods: The simulated enhanced SPN were used the mixture of nonionic iodinated contrast agent (Iopromide 370mgI/100 ml) and normal saline and then randomly placed inside an anthropomorphic chest phantom. The phantom was examined on SOMATOM definition flash with dual mode (80/140 kV) and single energy mode (120 kV) (the same CTDIvol). Nonlinear blending images and linear blending images with a weighting factor of 0.3 were generated and the image qualities were analyzed.
Results: For different simulated density SPN, when 0 HU was chosen as the Blending Center (BC) and 0 to 30 HU were chosen as the Blending width (BW), the nonlinear blending images yielded a higher contrast-to-noise (CNR). There were significant differences in the image noise and signal-to-noise (SNR) of different simulated density SPN at non-linear blending images, linear blending images and 120 kV images (p < .05); But the differences of CNR between the three groups were not statistically significant (p > .05). The SNR of different simulated density SPN at non-linear blending images was significantly increased compared with it at linear blending images and 120 kV images (p < .05); And the image noise at non-linear blending was lower than it at linear blending images (p < .05).
Conclusion: Nonlinear blending technique in dual-energy CT can increase the SNR of enhanced SPN, and it is helpful in diagnosis of SPN.
期刊介绍:
Journal of Receptors and Signal Tranduction is included in the following abstracting and indexing services:
BIOBASE; Biochemistry and Biophysics Citation Index; Biological Abstracts; BIOSIS Full Coverage Shared; BIOSIS Previews; Biotechnology Abstracts; Current Contents/Life Sciences; Derwent Chimera; Derwent Drug File; EMBASE; EMBIOLOGY; Journal Citation Reports/ Science Edition; PubMed/MedLine; Science Citation Index; SciSearch; SCOPUS; SIIC.