{"title":"内窥镜联合肾内手术中机器人辅助透视引导下肾脏通路的首例报道。","authors":"Kazumi Taguchi, Shuzo Hamamoto, Kengo Kawase, Tatsuya Hattori, Tomoki Okada, Ryosuke Chaya, Takashi Nagai, Taiki Kato, Atsushi Okada, Takahiro Yasui","doi":"10.1089/cren.2020.0125","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Background:</i></b> During percutaneous nephrolithotomy (PCNL) and endoscopic combined intrarenal surgery (ECIRS), obtaining renal access is the most critical step to achieving effective treatment without major intraoperative complications. Among a variety of methods attempted to improve the access, robot-assisted fluoroscopy-guided (RAFG) renal access has been introduced to mitigate technical human errors and overcome challenging learning curves. In this study, we present our first experience with an automated needle targeting with an X-ray (ANT-X) device for minimally invasive (mini-) ECIRS. <b><i>Case Presentation:</i></b> A 75-year-old healthy woman with a 6.0 cm<sup>3</sup> left kidney stone was referred to our hospital for surgical treatment. The patient underwent mini-ECIRS utilizing RAFG renal access without complication, and the stone was completely removed. The ureteral stent and transurethral catheter were removed on postoperative day 2, and the patient was discharged on postoperative day 3. There were no residual fragments detected by CT as of 3 months after the surgery. <b><i>Conclusion:</i></b> To our knowledge, this is the first report of the effective use of RAFG mini-ECIRS for a kidney stone. The overall outcome was positive, indicating the feasibility of ANT-X use for PCNL and ECIRS.</p>","PeriodicalId":36779,"journal":{"name":"Journal of Endourology Case Reports","volume":"6 4","pages":"310-314"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1089/cren.2020.0125","citationCount":"1","resultStr":"{\"title\":\"The First Case Report of Robot-Assisted Fluoroscopy-Guided Renal Access During Endoscopic Combined Intrarenal Surgery.\",\"authors\":\"Kazumi Taguchi, Shuzo Hamamoto, Kengo Kawase, Tatsuya Hattori, Tomoki Okada, Ryosuke Chaya, Takashi Nagai, Taiki Kato, Atsushi Okada, Takahiro Yasui\",\"doi\":\"10.1089/cren.2020.0125\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b><i>Background:</i></b> During percutaneous nephrolithotomy (PCNL) and endoscopic combined intrarenal surgery (ECIRS), obtaining renal access is the most critical step to achieving effective treatment without major intraoperative complications. Among a variety of methods attempted to improve the access, robot-assisted fluoroscopy-guided (RAFG) renal access has been introduced to mitigate technical human errors and overcome challenging learning curves. In this study, we present our first experience with an automated needle targeting with an X-ray (ANT-X) device for minimally invasive (mini-) ECIRS. <b><i>Case Presentation:</i></b> A 75-year-old healthy woman with a 6.0 cm<sup>3</sup> left kidney stone was referred to our hospital for surgical treatment. The patient underwent mini-ECIRS utilizing RAFG renal access without complication, and the stone was completely removed. The ureteral stent and transurethral catheter were removed on postoperative day 2, and the patient was discharged on postoperative day 3. There were no residual fragments detected by CT as of 3 months after the surgery. <b><i>Conclusion:</i></b> To our knowledge, this is the first report of the effective use of RAFG mini-ECIRS for a kidney stone. The overall outcome was positive, indicating the feasibility of ANT-X use for PCNL and ECIRS.</p>\",\"PeriodicalId\":36779,\"journal\":{\"name\":\"Journal of Endourology Case Reports\",\"volume\":\"6 4\",\"pages\":\"310-314\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-12-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1089/cren.2020.0125\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Endourology Case Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1089/cren.2020.0125\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2020/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Endourology Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1089/cren.2020.0125","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
The First Case Report of Robot-Assisted Fluoroscopy-Guided Renal Access During Endoscopic Combined Intrarenal Surgery.
Background: During percutaneous nephrolithotomy (PCNL) and endoscopic combined intrarenal surgery (ECIRS), obtaining renal access is the most critical step to achieving effective treatment without major intraoperative complications. Among a variety of methods attempted to improve the access, robot-assisted fluoroscopy-guided (RAFG) renal access has been introduced to mitigate technical human errors and overcome challenging learning curves. In this study, we present our first experience with an automated needle targeting with an X-ray (ANT-X) device for minimally invasive (mini-) ECIRS. Case Presentation: A 75-year-old healthy woman with a 6.0 cm3 left kidney stone was referred to our hospital for surgical treatment. The patient underwent mini-ECIRS utilizing RAFG renal access without complication, and the stone was completely removed. The ureteral stent and transurethral catheter were removed on postoperative day 2, and the patient was discharged on postoperative day 3. There were no residual fragments detected by CT as of 3 months after the surgery. Conclusion: To our knowledge, this is the first report of the effective use of RAFG mini-ECIRS for a kidney stone. The overall outcome was positive, indicating the feasibility of ANT-X use for PCNL and ECIRS.