普及医疗筛查动脉粥样硬化疾病的最新进展

IF 17.2 1区 工程技术 Q1 ENGINEERING, BIOMEDICAL IEEE Reviews in Biomedical Engineering Pub Date : 2021-03-18 DOI:10.1109/RBME.2021.3081180
Jingjing Luo;Zhengrong Yan;Shijie Guo;Wei Chen
{"title":"普及医疗筛查动脉粥样硬化疾病的最新进展","authors":"Jingjing Luo;Zhengrong Yan;Shijie Guo;Wei Chen","doi":"10.1109/RBME.2021.3081180","DOIUrl":null,"url":null,"abstract":"Atherosclerosis screening helps the medical model transform from therapeutic medicine to preventive medicine by assessing degree of atherosclerosis prior to the occurrence of fatal vascular events. Pervasive screening emphasizes atherosclerotic monitoring with easy access, quick process, and advanced computing. In this work, we introduced five cutting-edge pervasive technologies including imaging photoplethysmography (iPPG), laser Doppler, radio frequency (RF), thermal imaging (TI), optical fiber sensing and piezoelectric sensor. IPPG measures physiological parameters by using video images that record the subtle skin color changes consistent with cardiac-synchronous blood volume changes in subcutaneous arteries and capillaries. Laser Doppler obtained the information on blood flow by analyzing the spectral components of backscattered light from the illuminated tissues’ surface. RF is based on Doppler shift caused by the periodic movement of the chest wall induced by respiration and heartbeat. TI measures vital signs by detecting electromagnetic radiation emitted by blood flow. The working principle of optical fiber sensor is to detect the change of light properties caused by the interaction between the measured physiological parameter and the entering light. Piezoelectric sensors are based on the piezoelectric effect of dielectrics. All these pervasive technologies are noninvasive, mobile, and can detect physiological parameters related to atherosclerosis screening.","PeriodicalId":39235,"journal":{"name":"IEEE Reviews in Biomedical Engineering","volume":"15 ","pages":"293-308"},"PeriodicalIF":17.2000,"publicationDate":"2021-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/RBME.2021.3081180","citationCount":"2","resultStr":"{\"title\":\"Recent Advances in Atherosclerotic Disease Screening Using Pervasive Healthcare\",\"authors\":\"Jingjing Luo;Zhengrong Yan;Shijie Guo;Wei Chen\",\"doi\":\"10.1109/RBME.2021.3081180\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Atherosclerosis screening helps the medical model transform from therapeutic medicine to preventive medicine by assessing degree of atherosclerosis prior to the occurrence of fatal vascular events. Pervasive screening emphasizes atherosclerotic monitoring with easy access, quick process, and advanced computing. In this work, we introduced five cutting-edge pervasive technologies including imaging photoplethysmography (iPPG), laser Doppler, radio frequency (RF), thermal imaging (TI), optical fiber sensing and piezoelectric sensor. IPPG measures physiological parameters by using video images that record the subtle skin color changes consistent with cardiac-synchronous blood volume changes in subcutaneous arteries and capillaries. Laser Doppler obtained the information on blood flow by analyzing the spectral components of backscattered light from the illuminated tissues’ surface. RF is based on Doppler shift caused by the periodic movement of the chest wall induced by respiration and heartbeat. TI measures vital signs by detecting electromagnetic radiation emitted by blood flow. The working principle of optical fiber sensor is to detect the change of light properties caused by the interaction between the measured physiological parameter and the entering light. Piezoelectric sensors are based on the piezoelectric effect of dielectrics. All these pervasive technologies are noninvasive, mobile, and can detect physiological parameters related to atherosclerosis screening.\",\"PeriodicalId\":39235,\"journal\":{\"name\":\"IEEE Reviews in Biomedical Engineering\",\"volume\":\"15 \",\"pages\":\"293-308\"},\"PeriodicalIF\":17.2000,\"publicationDate\":\"2021-03-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/RBME.2021.3081180\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Reviews in Biomedical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/9435066/\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Reviews in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/9435066/","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 2

摘要

动脉粥样硬化筛查通过在致命血管事件发生前评估动脉粥样硬化程度,帮助医学模式从治疗医学转变为预防医学。普及筛查强调动脉粥样硬化监测,具有易于访问、快速处理和高级计算功能。在这项工作中,我们介绍了五种尖端的普适技术,包括成像光电体积描记术(iPPG)、激光多普勒、射频(RF)、热成像(TI)、光纤传感和压电传感器。IPPG通过使用视频图像来测量生理参数,视频图像记录了与皮下动脉和毛细血管中心脏同步血容量变化一致的细微肤色变化。激光多普勒通过分析照射组织表面后向散射光的光谱成分,获得了血流信息。射频是基于呼吸和心跳引起的胸壁周期性运动引起的多普勒频移。TI通过检测血液流动发出的电磁辐射来测量生命体征。光纤传感器的工作原理是检测测量的生理参数与入射光之间的相互作用引起的光特性的变化。压电传感器是基于电介质的压电效应。所有这些普及的技术都是无创的、可移动的,并且可以检测与动脉粥样硬化筛查相关的生理参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Recent Advances in Atherosclerotic Disease Screening Using Pervasive Healthcare
Atherosclerosis screening helps the medical model transform from therapeutic medicine to preventive medicine by assessing degree of atherosclerosis prior to the occurrence of fatal vascular events. Pervasive screening emphasizes atherosclerotic monitoring with easy access, quick process, and advanced computing. In this work, we introduced five cutting-edge pervasive technologies including imaging photoplethysmography (iPPG), laser Doppler, radio frequency (RF), thermal imaging (TI), optical fiber sensing and piezoelectric sensor. IPPG measures physiological parameters by using video images that record the subtle skin color changes consistent with cardiac-synchronous blood volume changes in subcutaneous arteries and capillaries. Laser Doppler obtained the information on blood flow by analyzing the spectral components of backscattered light from the illuminated tissues’ surface. RF is based on Doppler shift caused by the periodic movement of the chest wall induced by respiration and heartbeat. TI measures vital signs by detecting electromagnetic radiation emitted by blood flow. The working principle of optical fiber sensor is to detect the change of light properties caused by the interaction between the measured physiological parameter and the entering light. Piezoelectric sensors are based on the piezoelectric effect of dielectrics. All these pervasive technologies are noninvasive, mobile, and can detect physiological parameters related to atherosclerosis screening.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEEE Reviews in Biomedical Engineering
IEEE Reviews in Biomedical Engineering Engineering-Biomedical Engineering
CiteScore
31.70
自引率
0.60%
发文量
93
期刊介绍: IEEE Reviews in Biomedical Engineering (RBME) serves as a platform to review the state-of-the-art and trends in the interdisciplinary field of biomedical engineering, which encompasses engineering, life sciences, and medicine. The journal aims to consolidate research and reviews for members of all IEEE societies interested in biomedical engineering. Recognizing the demand for comprehensive reviews among authors of various IEEE journals, RBME addresses this need by receiving, reviewing, and publishing scholarly works under one umbrella. It covers a broad spectrum, from historical to modern developments in biomedical engineering and the integration of technologies from various IEEE societies into the life sciences and medicine.
期刊最新文献
Foundation Model for Advancing Healthcare: Challenges, Opportunities and Future Directions. A Manual for Genome and Transcriptome Engineering. Artificial General Intelligence for Medical Imaging Analysis. A Survey of Few-Shot Learning for Biomedical Time Series. The Physiome Project and Digital Twins.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1