伊朗O型献血者:异凝集素滴度和免疫球蛋白G亚类的评估

Q4 Medicine Immunohematology Pub Date : 2021-03-01 DOI:10.21307/immunohematology-2021-002
S Arabi, M Moghaddam, A A Pourfathollah, A Aghaie, M Mosaed
{"title":"伊朗O型献血者:异凝集素滴度和免疫球蛋白G亚类的评估","authors":"S Arabi,&nbsp;M Moghaddam,&nbsp;A A Pourfathollah,&nbsp;A Aghaie,&nbsp;M Mosaed","doi":"10.21307/immunohematology-2021-002","DOIUrl":null,"url":null,"abstract":"<p><p>This study aims to determine the most frequent titers of anti-A and anti-B (both presumed immunoglobulin [Ig]M and IgG) in Iranian group O blood donors and to compare these titer values with those found in other studies. In addition, alloantibody production and plasma levels of four IgG subclasses were compared between the high-titer and non-high-titer study groups. This study investigated anti-A and anti-B titers in 358 plasma samples. Based on these results, two study groups (high-titer and non-high-titer) were formed. Antibody detection tests were performed to detect unexpected antibodies to D, C, c, E, e, K, k, Fy<sup>a</sup>, Fy<sup>b</sup>, Jk<sup>a</sup>, Jk<sup>b</sup>, M, N, S, s, P1, Le<sup>a</sup>, and Le<sup>b</sup>. Four IgG subclasses were also evaluated through nephelometry assay. The most frequent titer obtained by room temperature and indirect antiglobulin tube tests was 256. The frequency of titers ≥512 was 31.5 percent. None of the cases showed unexpected RBC alloantibodies. IgG2 levels were significantly higher in the high-titer group. Evaluation of isoagglutinin titers in group O Iranian blood donors can provide insight into the frequency of isoagglutinin titers both within the Iranian population and as compared with other populations. A significant difference in IgG2 levels between the high-titer and non-high-titer groups was identified. More investigation needs to be conducted on the root cause of this finding. <b><i>Immunohematology 2021;37:5-12</i></b> .</p><p><p>This study aims to determine the most frequent titers of anti-A and anti-B (both presumed immunoglobulin [Ig]M and IgG) in Iranian group O blood donors and to compare these titer values with those found in other studies. In addition, alloantibody production and plasma levels of four IgG subclasses were compared between the high-titer and non–high-titer study groups. This study investigated anti-A and anti-B titers in 358 plasma samples. Based on these results, two study groups (high-titer and non–high-titer) were formed. Antibody detection tests were performed to detect unexpected antibodies to D, C, c, E, e, K, k, Fy<sup>a</sup>, Fy<sup>b</sup>, Jk<sup>a</sup>, Jk<sup>b</sup>, M, N, S, s, P1, Le<sup>a</sup>, and Le<sup>b</sup>. Four IgG subclasses were also evaluated through nephelometry assay. The most frequent titer obtained by room temperature and indirect antiglobulin tube tests was 256. The frequency of titers ≥512 was 31.5 percent. None of the cases showed unexpected RBC alloantibodies. IgG2 levels were significantly higher in the high-titer group. Evaluation of isoagglutinin titers in group O Iranian blood donors can provide insight into the frequency of isoagglutinin titers both within the Iranian population and as compared with other populations. A significant difference in IgG2 levels between the high-titer and non–high-titer groups was identified. More investigation needs to be conducted on the root cause of this finding. <b><i>Immunohematology 2021;37:5–12</i></b> .</p>","PeriodicalId":13357,"journal":{"name":"Immunohematology","volume":" ","pages":"5-12"},"PeriodicalIF":0.0000,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Group O blood donors in Iran: evaluation of isoagglutinin titers and immunoglobulin G subclasses.\",\"authors\":\"S Arabi,&nbsp;M Moghaddam,&nbsp;A A Pourfathollah,&nbsp;A Aghaie,&nbsp;M Mosaed\",\"doi\":\"10.21307/immunohematology-2021-002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study aims to determine the most frequent titers of anti-A and anti-B (both presumed immunoglobulin [Ig]M and IgG) in Iranian group O blood donors and to compare these titer values with those found in other studies. In addition, alloantibody production and plasma levels of four IgG subclasses were compared between the high-titer and non-high-titer study groups. This study investigated anti-A and anti-B titers in 358 plasma samples. Based on these results, two study groups (high-titer and non-high-titer) were formed. Antibody detection tests were performed to detect unexpected antibodies to D, C, c, E, e, K, k, Fy<sup>a</sup>, Fy<sup>b</sup>, Jk<sup>a</sup>, Jk<sup>b</sup>, M, N, S, s, P1, Le<sup>a</sup>, and Le<sup>b</sup>. Four IgG subclasses were also evaluated through nephelometry assay. The most frequent titer obtained by room temperature and indirect antiglobulin tube tests was 256. The frequency of titers ≥512 was 31.5 percent. None of the cases showed unexpected RBC alloantibodies. IgG2 levels were significantly higher in the high-titer group. Evaluation of isoagglutinin titers in group O Iranian blood donors can provide insight into the frequency of isoagglutinin titers both within the Iranian population and as compared with other populations. A significant difference in IgG2 levels between the high-titer and non-high-titer groups was identified. More investigation needs to be conducted on the root cause of this finding. <b><i>Immunohematology 2021;37:5-12</i></b> .</p><p><p>This study aims to determine the most frequent titers of anti-A and anti-B (both presumed immunoglobulin [Ig]M and IgG) in Iranian group O blood donors and to compare these titer values with those found in other studies. In addition, alloantibody production and plasma levels of four IgG subclasses were compared between the high-titer and non–high-titer study groups. This study investigated anti-A and anti-B titers in 358 plasma samples. Based on these results, two study groups (high-titer and non–high-titer) were formed. Antibody detection tests were performed to detect unexpected antibodies to D, C, c, E, e, K, k, Fy<sup>a</sup>, Fy<sup>b</sup>, Jk<sup>a</sup>, Jk<sup>b</sup>, M, N, S, s, P1, Le<sup>a</sup>, and Le<sup>b</sup>. Four IgG subclasses were also evaluated through nephelometry assay. The most frequent titer obtained by room temperature and indirect antiglobulin tube tests was 256. The frequency of titers ≥512 was 31.5 percent. None of the cases showed unexpected RBC alloantibodies. IgG2 levels were significantly higher in the high-titer group. Evaluation of isoagglutinin titers in group O Iranian blood donors can provide insight into the frequency of isoagglutinin titers both within the Iranian population and as compared with other populations. A significant difference in IgG2 levels between the high-titer and non–high-titer groups was identified. More investigation needs to be conducted on the root cause of this finding. <b><i>Immunohematology 2021;37:5–12</i></b> .</p>\",\"PeriodicalId\":13357,\"journal\":{\"name\":\"Immunohematology\",\"volume\":\" \",\"pages\":\"5-12\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Immunohematology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21307/immunohematology-2021-002\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Immunohematology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21307/immunohematology-2021-002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在确定伊朗O组献血者中最常见的抗a和抗b(推测为免疫球蛋白[Ig]M和IgG)滴度,并将这些滴度值与其他研究中发现的滴度值进行比较。此外,比较了高滴度组和非高滴度组的同种抗体产生和血浆中四种IgG亚类的水平。本研究测定了358份血浆样本的抗a和抗b滴度。根据这些结果,形成两个研究组(高效价组和非高效价组)。进行抗体检测试验,检测非预期抗体D、C、C、E、E、K、K、Fya、Fyb、Jka、Jkb、M、N、S、S、P1、Lea和Leb。四种IgG亚类也通过浊度测定法进行评估。室温和间接抗球蛋白管试验获得的最常见滴度为256。滴度≥512的频率为31.5%。所有病例均未出现意外的RBC同种异体抗体。高滴度组IgG2水平明显升高。评估伊朗O组献血者的异凝集素滴度可以深入了解伊朗人群中异凝集素滴度的频率以及与其他人群的比较。IgG2水平在高滴度组和非高滴度组之间有显著差异。需要对这一发现的根本原因进行更多的调查。免疫血液学2021;37:5-12本研究旨在确定伊朗O组献血者中最常见的抗a和抗b(推测为免疫球蛋白[Ig]M和IgG)滴度,并将这些滴度值与其他研究中发现的滴度值进行比较。此外,比较了高滴度组和非高滴度组的同种抗体产生和血浆中四种IgG亚类的水平。本研究测定了358份血浆样本的抗a和抗b滴度。根据这些结果,形成两个研究组(高效价组和非高效价组)。进行抗体检测试验,检测非预期抗体D、C、C、E、E、K、K、Fya、Fyb、Jka、Jkb、M、N、S、S、P1、Lea和Leb。四种IgG亚类也通过浊度测定法进行评估。室温和间接抗球蛋白管试验获得的最常见滴度为256。滴度≥512的频率为31.5%。所有病例均未出现意外的RBC同种异体抗体。高滴度组IgG2水平明显升高。评估伊朗O组献血者的异凝集素滴度可以深入了解伊朗人群中异凝集素滴度的频率以及与其他人群的比较。IgG2水平在高滴度组和非高滴度组之间有显著差异。需要对这一发现的根本原因进行更多的调查。免疫血液学2021;37:5-12。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Group O blood donors in Iran: evaluation of isoagglutinin titers and immunoglobulin G subclasses.

This study aims to determine the most frequent titers of anti-A and anti-B (both presumed immunoglobulin [Ig]M and IgG) in Iranian group O blood donors and to compare these titer values with those found in other studies. In addition, alloantibody production and plasma levels of four IgG subclasses were compared between the high-titer and non-high-titer study groups. This study investigated anti-A and anti-B titers in 358 plasma samples. Based on these results, two study groups (high-titer and non-high-titer) were formed. Antibody detection tests were performed to detect unexpected antibodies to D, C, c, E, e, K, k, Fya, Fyb, Jka, Jkb, M, N, S, s, P1, Lea, and Leb. Four IgG subclasses were also evaluated through nephelometry assay. The most frequent titer obtained by room temperature and indirect antiglobulin tube tests was 256. The frequency of titers ≥512 was 31.5 percent. None of the cases showed unexpected RBC alloantibodies. IgG2 levels were significantly higher in the high-titer group. Evaluation of isoagglutinin titers in group O Iranian blood donors can provide insight into the frequency of isoagglutinin titers both within the Iranian population and as compared with other populations. A significant difference in IgG2 levels between the high-titer and non-high-titer groups was identified. More investigation needs to be conducted on the root cause of this finding. Immunohematology 2021;37:5-12 .

This study aims to determine the most frequent titers of anti-A and anti-B (both presumed immunoglobulin [Ig]M and IgG) in Iranian group O blood donors and to compare these titer values with those found in other studies. In addition, alloantibody production and plasma levels of four IgG subclasses were compared between the high-titer and non–high-titer study groups. This study investigated anti-A and anti-B titers in 358 plasma samples. Based on these results, two study groups (high-titer and non–high-titer) were formed. Antibody detection tests were performed to detect unexpected antibodies to D, C, c, E, e, K, k, Fya, Fyb, Jka, Jkb, M, N, S, s, P1, Lea, and Leb. Four IgG subclasses were also evaluated through nephelometry assay. The most frequent titer obtained by room temperature and indirect antiglobulin tube tests was 256. The frequency of titers ≥512 was 31.5 percent. None of the cases showed unexpected RBC alloantibodies. IgG2 levels were significantly higher in the high-titer group. Evaluation of isoagglutinin titers in group O Iranian blood donors can provide insight into the frequency of isoagglutinin titers both within the Iranian population and as compared with other populations. A significant difference in IgG2 levels between the high-titer and non–high-titer groups was identified. More investigation needs to be conducted on the root cause of this finding. Immunohematology 2021;37:5–12 .

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Immunohematology
Immunohematology Medicine-Medicine (all)
CiteScore
1.30
自引率
0.00%
发文量
18
期刊最新文献
A challenging case of hemolytic disease of the fetus and newborn (HDFN) due to anti-Ku in a K0 (Kellnull) mother. Mixed-field ABO front typing as an early sign of disease recurrence in ABO-matched stem cell transplantation. Red blood cell extended antigen typing in Omani patients with sickle cell disease to enhance daily transfusion practice. The American Rare Donor Program: 25 years supporting rare blood needs. Contents.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1