牙本质结合及材料厚度对二硅酸锂玻璃陶瓷弯曲性能的影响。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2021-07-23 DOI:10.3290/j.jad.b1650013
Francesco De Angelis, Camillo D'Arcangelo, Mirco Vadini
{"title":"牙本质结合及材料厚度对二硅酸锂玻璃陶瓷弯曲性能的影响。","authors":"Francesco De Angelis,&nbsp;Camillo D'Arcangelo,&nbsp;Mirco Vadini","doi":"10.3290/j.jad.b1650013","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Thanks to adhesive techniques and strengthened glass ceramics, ultrathin bonded occlusal veneers have been recently introduced. However, since a universally accepted thickness limit for ultrathin ceramics has yet to be established, their resistance to fracture needs to be better investigated. The purpose of this in vitro study was to evaluate the effect of dentin bonding on the flexural properties (ie, fracture load and flexural strength) of a lithium-disilicate (LD) glass ceramic when used in thicknesses equal to or less than the manufacturer's recommendations for occlusal restorations.</p><p><strong>Materials and methods: </strong>A total of 96 dentin slices (2.0 mm thick and 15 mm long) were obtained by sectioning bovine teeth along their long axes. LD slices of different thicknesses (1.5 mm/1.3 mm/1.0 mm/0.8 mm/0.6 mm) and 15 mm in length were cut from CAD/CAM LD blocks (IPS e.max CAD-C16). In each of 5 experimental groups, 16 dentin slices were adhesively luted to 16 LD slices (n = 16) of the same thickness, in order to create 16 bi-layered dentin-LD bonded assemblies. In the control group, the 16 remaining dentin slices were conventionally cemented to 1.5-mm-thick LD slices (n = 16) using a resin-modified glass-ionomer cement (FujiCEM 2). All dentin-LD assemblies were cut perpendicularly to their joint interface, in order to obtain 1-mm-wide, 15-mm-long bi-layered prismatic beams, having the following final thicknesses: for the 5 experimental groups, 2 mm (dentin layer) + 1.5 mm/ 1.3 mm/1.0 mm/0.8 mm/0.6 mm (LD layer); for the control group, 2 mm (dentin layer) + 1.5 mm (LD layer). All prismatic beams were subjected to a three-point bending test (14-mm span, load applied on the LD side). Fracture loads (N) and flexural strengths (MPa) were recorded. Data were analyzed using one-way ANOVA on ranks tests (α = 0.05). The correlations between the recorded flexural strengths and the dentin:LD thickness ratio and between the flexural strength and the luting strategy were also investigated. The failure modes were observed and classified.</p><p><strong>Results: </strong>No statistically significant differences were recorded between the conventionally luted control group (LD thickness 1.5 mm; fracture load 35.26 N; flexural strength 60.44 MPa) and the thinnest adhesively luted experimental group (LD thickness 0.6 mm; fracture load 28.97 N; flexural strength 90.01 MPa) in terms of fracture load and flexural strength. A fracture involving both the dentin and the LD of the bi-layered prismatic beam, but without any debonding between the LD and the dentin substrates of the broken specimen, was the most common failure mode observed on the adhesively luted samples.</p><p><strong>Conclusion: </strong>Compared to conventional cementation, when LD is bonded to dentin, the flexural properties of the whole system are improved, and the two different substrates seem to behave like a single unit. Once adhesively luted, 0.6-mm-thick LD has the same fracture load and flexural strength as that of the conventionally luted 1.5-mm-thick LD.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":"23 4","pages":"309-318"},"PeriodicalIF":4.6000,"publicationDate":"2021-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"The Effect of Dentin Bonding and Material Thickness on the Flexural Properties of a Lithium-Disilicate Glass-Ceramic.\",\"authors\":\"Francesco De Angelis,&nbsp;Camillo D'Arcangelo,&nbsp;Mirco Vadini\",\"doi\":\"10.3290/j.jad.b1650013\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Thanks to adhesive techniques and strengthened glass ceramics, ultrathin bonded occlusal veneers have been recently introduced. However, since a universally accepted thickness limit for ultrathin ceramics has yet to be established, their resistance to fracture needs to be better investigated. The purpose of this in vitro study was to evaluate the effect of dentin bonding on the flexural properties (ie, fracture load and flexural strength) of a lithium-disilicate (LD) glass ceramic when used in thicknesses equal to or less than the manufacturer's recommendations for occlusal restorations.</p><p><strong>Materials and methods: </strong>A total of 96 dentin slices (2.0 mm thick and 15 mm long) were obtained by sectioning bovine teeth along their long axes. LD slices of different thicknesses (1.5 mm/1.3 mm/1.0 mm/0.8 mm/0.6 mm) and 15 mm in length were cut from CAD/CAM LD blocks (IPS e.max CAD-C16). In each of 5 experimental groups, 16 dentin slices were adhesively luted to 16 LD slices (n = 16) of the same thickness, in order to create 16 bi-layered dentin-LD bonded assemblies. In the control group, the 16 remaining dentin slices were conventionally cemented to 1.5-mm-thick LD slices (n = 16) using a resin-modified glass-ionomer cement (FujiCEM 2). All dentin-LD assemblies were cut perpendicularly to their joint interface, in order to obtain 1-mm-wide, 15-mm-long bi-layered prismatic beams, having the following final thicknesses: for the 5 experimental groups, 2 mm (dentin layer) + 1.5 mm/ 1.3 mm/1.0 mm/0.8 mm/0.6 mm (LD layer); for the control group, 2 mm (dentin layer) + 1.5 mm (LD layer). All prismatic beams were subjected to a three-point bending test (14-mm span, load applied on the LD side). Fracture loads (N) and flexural strengths (MPa) were recorded. Data were analyzed using one-way ANOVA on ranks tests (α = 0.05). The correlations between the recorded flexural strengths and the dentin:LD thickness ratio and between the flexural strength and the luting strategy were also investigated. The failure modes were observed and classified.</p><p><strong>Results: </strong>No statistically significant differences were recorded between the conventionally luted control group (LD thickness 1.5 mm; fracture load 35.26 N; flexural strength 60.44 MPa) and the thinnest adhesively luted experimental group (LD thickness 0.6 mm; fracture load 28.97 N; flexural strength 90.01 MPa) in terms of fracture load and flexural strength. A fracture involving both the dentin and the LD of the bi-layered prismatic beam, but without any debonding between the LD and the dentin substrates of the broken specimen, was the most common failure mode observed on the adhesively luted samples.</p><p><strong>Conclusion: </strong>Compared to conventional cementation, when LD is bonded to dentin, the flexural properties of the whole system are improved, and the two different substrates seem to behave like a single unit. Once adhesively luted, 0.6-mm-thick LD has the same fracture load and flexural strength as that of the conventionally luted 1.5-mm-thick LD.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":\"23 4\",\"pages\":\"309-318\"},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2021-07-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3290/j.jad.b1650013\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3290/j.jad.b1650013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 5

摘要

目的:由于胶粘剂技术和强化玻璃陶瓷,超薄粘结咬合贴面最近被引入。然而,由于超薄陶瓷的普遍接受的厚度限制尚未建立,它们的抗断裂性需要更好的研究。这项体外研究的目的是评估牙本质结合对二硅酸锂(LD)玻璃陶瓷的弯曲性能(即断裂载荷和弯曲强度)的影响,当使用厚度等于或less比制造商推荐的咬合修复。材料与方法:采用牛牙齿长轴切片法,获得96片(厚2.0 mm,长15mm)牙本质切片。从CAD/CAM LD块(IPS e.max CAD- c16)上切割出不同厚度(1.5 mm/1.3 mm/1.0 mm/0.8 mm/0.6 mm)、长度为15mm的LD切片。在5个实验组中,每组将16个牙本质切片与16个相同厚度的LD切片(n = 16)粘连,形成16个双层牙本质-LD粘合组件。在对照组中,使用树脂改性玻璃离子水门汀(FujiCEM 2)将剩余的16块牙本质片常规粘合到1.5 mm厚的LD片(n = 16)上。所有牙本质-LD组件垂直于其接合界面切割,以获得1 mm宽,15 mm长的双层棱柱梁,其最终厚度如下:5个实验组为2mm(牙本质层)+ 1.5 mm/ 1.3 mm/1.0 mm/0.8 mm/0.6 mm (LD层);对照组2mm(牙本质层)+ 1.5 mm (LD层)。所有棱柱梁都进行了三点弯曲试验(14毫米跨度,荷载施加在LD侧)。记录断裂载荷(N)和抗弯强度(MPa)。数据分析采用单因素方差分析(α = 0.05)。研究了所记录的抗弯强度与牙本质:牙本质厚度比的关系,以及抗弯强度与处理策略的关系。对失效模式进行了观察和分类。结果:常规对照组(LD厚度1.5 mm;断裂载荷35.26 N;抗折强度60.44 MPa)和粘接剂厚度最薄的实验组(LD厚度0.6 mm;断裂载荷28.97 N;抗折强度90.01 MPa),按断裂载荷和抗折强度计算。两层棱柱状梁的牙本质和LD同时发生断裂,但LD与破裂试样的牙本质基底之间没有任何脱粘,这是在粘接的样品中观察到的最常见的破坏模式。结论:与传统胶结相比,当LD与牙本质结合时,整个系统的弯曲性能得到改善,两种不同的基质看起来像一个单一的单元。一旦粘接,0.6 mm厚的LD与1.5 mm厚的常规LD具有相同的断裂载荷和弯曲强度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Effect of Dentin Bonding and Material Thickness on the Flexural Properties of a Lithium-Disilicate Glass-Ceramic.

Purpose: Thanks to adhesive techniques and strengthened glass ceramics, ultrathin bonded occlusal veneers have been recently introduced. However, since a universally accepted thickness limit for ultrathin ceramics has yet to be established, their resistance to fracture needs to be better investigated. The purpose of this in vitro study was to evaluate the effect of dentin bonding on the flexural properties (ie, fracture load and flexural strength) of a lithium-disilicate (LD) glass ceramic when used in thicknesses equal to or less than the manufacturer's recommendations for occlusal restorations.

Materials and methods: A total of 96 dentin slices (2.0 mm thick and 15 mm long) were obtained by sectioning bovine teeth along their long axes. LD slices of different thicknesses (1.5 mm/1.3 mm/1.0 mm/0.8 mm/0.6 mm) and 15 mm in length were cut from CAD/CAM LD blocks (IPS e.max CAD-C16). In each of 5 experimental groups, 16 dentin slices were adhesively luted to 16 LD slices (n = 16) of the same thickness, in order to create 16 bi-layered dentin-LD bonded assemblies. In the control group, the 16 remaining dentin slices were conventionally cemented to 1.5-mm-thick LD slices (n = 16) using a resin-modified glass-ionomer cement (FujiCEM 2). All dentin-LD assemblies were cut perpendicularly to their joint interface, in order to obtain 1-mm-wide, 15-mm-long bi-layered prismatic beams, having the following final thicknesses: for the 5 experimental groups, 2 mm (dentin layer) + 1.5 mm/ 1.3 mm/1.0 mm/0.8 mm/0.6 mm (LD layer); for the control group, 2 mm (dentin layer) + 1.5 mm (LD layer). All prismatic beams were subjected to a three-point bending test (14-mm span, load applied on the LD side). Fracture loads (N) and flexural strengths (MPa) were recorded. Data were analyzed using one-way ANOVA on ranks tests (α = 0.05). The correlations between the recorded flexural strengths and the dentin:LD thickness ratio and between the flexural strength and the luting strategy were also investigated. The failure modes were observed and classified.

Results: No statistically significant differences were recorded between the conventionally luted control group (LD thickness 1.5 mm; fracture load 35.26 N; flexural strength 60.44 MPa) and the thinnest adhesively luted experimental group (LD thickness 0.6 mm; fracture load 28.97 N; flexural strength 90.01 MPa) in terms of fracture load and flexural strength. A fracture involving both the dentin and the LD of the bi-layered prismatic beam, but without any debonding between the LD and the dentin substrates of the broken specimen, was the most common failure mode observed on the adhesively luted samples.

Conclusion: Compared to conventional cementation, when LD is bonded to dentin, the flexural properties of the whole system are improved, and the two different substrates seem to behave like a single unit. Once adhesively luted, 0.6-mm-thick LD has the same fracture load and flexural strength as that of the conventionally luted 1.5-mm-thick LD.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1