埃塞俄比亚西北部贡达尔大学第三眼科护理和培训中心白内障手术的屈光结果。

IF 1.8 Q3 HEALTH CARE SCIENCES & SERVICES Patient Related Outcome Measures Pub Date : 2021-06-10 DOI:10.2147/PROM.S308816
Masresha Mengistu, Fisseha Admassu, Teshager Wondale, Asamere Tsegaw
{"title":"埃塞俄比亚西北部贡达尔大学第三眼科护理和培训中心白内障手术的屈光结果。","authors":"Masresha Mengistu,&nbsp;Fisseha Admassu,&nbsp;Teshager Wondale,&nbsp;Asamere Tsegaw","doi":"10.2147/PROM.S308816","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>According to World Health Organization (WHO), cataract is the leading cause of blindness and visual impairment throughout the world. Post-operative refractive error is one of the commonest reasons for poor visual outcome after cataract surgery especially in developing countries where the standard modern biometry equipments are not available. The objective of this study was to assess the refractive outcome of cataract surgery done at University of Gondar (UoG) Tertiary Eye Care and Training Center, North West Ethiopia.</p><p><strong>Methods: </strong>A descriptive cross-sectional study was done on 66 patients who had undergone manual small incision cataract surgery (MSICS) and fulfilled the inclusion criteria at UoG Tertiary Eye Care and Training Center from July 15 2019 to October 15 2019.</p><p><strong>Results: </strong>From 90 post-operatively refracted eyes, 58 (64.4%) eyes achieved a target refraction of ±1.00 Diopter (D). The right and left eyes achieved mean post-operative refraction SE of -0.073±1.45D and -0.93±1.70 D, respectively. But only 54 (60%) eyes were implanted with the calculated IOL power and for the remaining 40% the calculated IOL was not available at the store. And the target (Good) post-operative uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA) was achieved in 66.7% and 82.2% eyes, respectively.</p><p><strong>Conclusion: </strong>The post-operative refractive outcome after cataract surgery at the center is low. For over one-third of operated eyes, the calculated IOL was not implanted due to the absence of the required IOL power at the store and, therefore, a wide range of IOL power should be available at the center.</p>","PeriodicalId":19747,"journal":{"name":"Patient Related Outcome Measures","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2021-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/78/f5/prom-12-173.PMC8203275.pdf","citationCount":"2","resultStr":"{\"title\":\"Refractive Outcome of Cataract Surgery Done at University of Gondar Tertiary Eye Care and Training Center, North West Ethiopia.\",\"authors\":\"Masresha Mengistu,&nbsp;Fisseha Admassu,&nbsp;Teshager Wondale,&nbsp;Asamere Tsegaw\",\"doi\":\"10.2147/PROM.S308816\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>According to World Health Organization (WHO), cataract is the leading cause of blindness and visual impairment throughout the world. Post-operative refractive error is one of the commonest reasons for poor visual outcome after cataract surgery especially in developing countries where the standard modern biometry equipments are not available. The objective of this study was to assess the refractive outcome of cataract surgery done at University of Gondar (UoG) Tertiary Eye Care and Training Center, North West Ethiopia.</p><p><strong>Methods: </strong>A descriptive cross-sectional study was done on 66 patients who had undergone manual small incision cataract surgery (MSICS) and fulfilled the inclusion criteria at UoG Tertiary Eye Care and Training Center from July 15 2019 to October 15 2019.</p><p><strong>Results: </strong>From 90 post-operatively refracted eyes, 58 (64.4%) eyes achieved a target refraction of ±1.00 Diopter (D). The right and left eyes achieved mean post-operative refraction SE of -0.073±1.45D and -0.93±1.70 D, respectively. But only 54 (60%) eyes were implanted with the calculated IOL power and for the remaining 40% the calculated IOL was not available at the store. And the target (Good) post-operative uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA) was achieved in 66.7% and 82.2% eyes, respectively.</p><p><strong>Conclusion: </strong>The post-operative refractive outcome after cataract surgery at the center is low. For over one-third of operated eyes, the calculated IOL was not implanted due to the absence of the required IOL power at the store and, therefore, a wide range of IOL power should be available at the center.</p>\",\"PeriodicalId\":19747,\"journal\":{\"name\":\"Patient Related Outcome Measures\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2021-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/78/f5/prom-12-173.PMC8203275.pdf\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Patient Related Outcome Measures\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2147/PROM.S308816\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"HEALTH CARE SCIENCES & SERVICES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Patient Related Outcome Measures","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/PROM.S308816","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 2

摘要

目的:根据世界卫生组织(世界卫生组织),白内障是全世界致盲和视力障碍的主要原因。术后屈光不正是白内障手术后视力不佳的最常见原因之一,尤其是在发展中国家,那里没有标准的现代生物测量设备。本研究的目的是评估贡达尔大学(UoG)第三眼科护理和培训中心白内障手术的屈光效果,埃塞俄比亚西北部。方法:对2019年7月15日至2019年10月15日在UoG第三级眼科护理和培训中心接受手动小切口白内障手术并符合纳入标准的66名患者进行了描述性横断面研究。结果:90只术后屈光眼中,58只(64.4%)眼睛实现了±1.00屈光度的目标屈光度。右眼和左眼术后平均屈光SE分别为-0.073±1.45D和-0.93±1.70D。但只有54只(60%)眼睛植入了计算的IOL功率,其余40%的IOL在商店里没有。目标(良好)术后裸眼视力(UCVA)和最佳矫正视力(BCVA)分别为66.7%和82.2%。结论:中心白内障手术后屈光度低。对于超过三分之一的手术眼,由于储存处缺乏所需的IOL功率,计算的IOL没有植入,因此,中心应提供大范围的IOL能量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Refractive Outcome of Cataract Surgery Done at University of Gondar Tertiary Eye Care and Training Center, North West Ethiopia.

Purpose: According to World Health Organization (WHO), cataract is the leading cause of blindness and visual impairment throughout the world. Post-operative refractive error is one of the commonest reasons for poor visual outcome after cataract surgery especially in developing countries where the standard modern biometry equipments are not available. The objective of this study was to assess the refractive outcome of cataract surgery done at University of Gondar (UoG) Tertiary Eye Care and Training Center, North West Ethiopia.

Methods: A descriptive cross-sectional study was done on 66 patients who had undergone manual small incision cataract surgery (MSICS) and fulfilled the inclusion criteria at UoG Tertiary Eye Care and Training Center from July 15 2019 to October 15 2019.

Results: From 90 post-operatively refracted eyes, 58 (64.4%) eyes achieved a target refraction of ±1.00 Diopter (D). The right and left eyes achieved mean post-operative refraction SE of -0.073±1.45D and -0.93±1.70 D, respectively. But only 54 (60%) eyes were implanted with the calculated IOL power and for the remaining 40% the calculated IOL was not available at the store. And the target (Good) post-operative uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA) was achieved in 66.7% and 82.2% eyes, respectively.

Conclusion: The post-operative refractive outcome after cataract surgery at the center is low. For over one-third of operated eyes, the calculated IOL was not implanted due to the absence of the required IOL power at the store and, therefore, a wide range of IOL power should be available at the center.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Patient Related Outcome Measures
Patient Related Outcome Measures HEALTH CARE SCIENCES & SERVICES-
自引率
4.80%
发文量
27
审稿时长
16 weeks
期刊最新文献
Ultra-Low Frequency Transmitted Ultrasound Breast Imaging vs DBT (Digital Breast Tomosynthesis): A Patient-Reported Outcome Study. Systematic Literature Review of Studies Reporting Measures of Functional Outcome or Quality of Life in People with Negative Symptoms of Schizophrenia. Validation and Cultural Adaptation of the Sinhala Translation of the Cardiff Acne Disability Index (CADI). Engaging Stakeholders to Develop a Roadmap for Dry Eye and MGD PCORI-Funded Research Prevalence, Clinical Characteristics and Determinants of Unsuccessful Treatment Outcomes Among Pulmonary Tuberculosis Patients: A 5-Year Registry-Based Retrospective Cohort Study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1