{"title":"在患者与假体不匹配的情况下调整 Konno 主动脉瓣成形术的技术。","authors":"Kerem M Vural, Timucin Sabuncu","doi":"10.1055/s-0041-1731283","DOIUrl":null,"url":null,"abstract":"<p><p>The patient-prosthesis mismatch has been reported as an important cause of adverse outcome following aortic valve replacement. The relief of patient-prosthesis mismatch generally requires a reoperation of comprehensive nature, which necessitates an extensive aortic root enlargement. The Konno aortoventriculoplasty represents an efficient treatment option, as this technique provides both extreme root enlargement and relief of the frequently associated subvalvular obstruction. However, the application and conduct of the procedure may somewhat differ from the pediatric Konno procedures. This article describes our surgical technique adaptation in Konno-aortoventriculoplasty for adult patient-prosthesis mismatch cases, highlighting the differing points from the pediatric-Konno.</p>","PeriodicalId":23057,"journal":{"name":"Thoracic and Cardiovascular Surgeon","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Technique for Adaptation of Konno Aortoventriculoplasty in Patient-Prosthesis Mismatch.\",\"authors\":\"Kerem M Vural, Timucin Sabuncu\",\"doi\":\"10.1055/s-0041-1731283\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The patient-prosthesis mismatch has been reported as an important cause of adverse outcome following aortic valve replacement. The relief of patient-prosthesis mismatch generally requires a reoperation of comprehensive nature, which necessitates an extensive aortic root enlargement. The Konno aortoventriculoplasty represents an efficient treatment option, as this technique provides both extreme root enlargement and relief of the frequently associated subvalvular obstruction. However, the application and conduct of the procedure may somewhat differ from the pediatric Konno procedures. This article describes our surgical technique adaptation in Konno-aortoventriculoplasty for adult patient-prosthesis mismatch cases, highlighting the differing points from the pediatric-Konno.</p>\",\"PeriodicalId\":23057,\"journal\":{\"name\":\"Thoracic and Cardiovascular Surgeon\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Thoracic and Cardiovascular Surgeon\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0041-1731283\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/8/10 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Thoracic and Cardiovascular Surgeon","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/s-0041-1731283","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/8/10 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

据报道,患者与假体不匹配是主动脉瓣置换术后出现不良后果的一个重要原因。要缓解患者与人工瓣膜不匹配的问题,通常需要进行全面的再次手术,这就必须扩大主动脉根部。Konno 主动脉瓣成形术是一种有效的治疗方案,因为这种技术既能使主动脉根部极度扩大,又能缓解经常伴有的瓣下梗阻。本文介绍了我们在成人患者-假体不匹配病例中对 Konno-aortoventriculoplasty 手术技术的调整,并强调了与小儿 Konno 手术的不同点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Technique for Adaptation of Konno Aortoventriculoplasty in Patient-Prosthesis Mismatch.

The patient-prosthesis mismatch has been reported as an important cause of adverse outcome following aortic valve replacement. The relief of patient-prosthesis mismatch generally requires a reoperation of comprehensive nature, which necessitates an extensive aortic root enlargement. The Konno aortoventriculoplasty represents an efficient treatment option, as this technique provides both extreme root enlargement and relief of the frequently associated subvalvular obstruction. However, the application and conduct of the procedure may somewhat differ from the pediatric Konno procedures. This article describes our surgical technique adaptation in Konno-aortoventriculoplasty for adult patient-prosthesis mismatch cases, highlighting the differing points from the pediatric-Konno.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.40
自引率
6.70%
发文量
365
审稿时长
3 months
期刊介绍: The Thoracic and Cardiovascular Surgeon publishes articles of the highest standard from internationally recognized thoracic and cardiovascular surgeons, cardiologists, anesthesiologists, physiologists, and pathologists. This journal is an essential resource for anyone working in this field. Original articles, short communications, reviews and important meeting announcements keep you abreast of key clinical advances, as well as providing the theoretical background of cardiovascular and thoracic surgery. Case reports are published in our Open Access companion journal The Thoracic and Cardiovascular Surgeon Reports.
期刊最新文献
HTK solution cardioplegia in paediatric patients: a meta-analysis. Intraoperative Invasive Coronary Angiography after Coronary Artery Bypass Grafting. Distal Events Following Emergent Operation for DeBakey Type I Aortic Dissection. Lactate Dehydrogenase Levels after aortic valve replacement: What do they tell us? Impact of High-Intensity Statin on Atrial Fibrillation After Off-Pump Coronary Artery Bypass.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1