Daniel Barvik;Martin Cerny;Marek Penhaker;Norbert Noury
{"title":"基于脉冲传输时间的无创连续血压估计:校准模型综述","authors":"Daniel Barvik;Martin Cerny;Marek Penhaker;Norbert Noury","doi":"10.1109/RBME.2021.3109643","DOIUrl":null,"url":null,"abstract":"Noninvasive continuous blood pressure estimation is a promising alternative to minimally invasive blood pressure measurement using cuff and invasive catheter measurement, because it opens the way to both long-term and continuous blood pressure monitoring in ecological situation. The most current estimation algorithm is based on pulse transit time measurement where at least two measured signals need to be acquired. From the pulse transit time values, it is possible to estimate the continuous blood pressure for each cardiac cycle. This measurement highly depends on arterial properties which are not easily accessible with common measurement techniques; but these properties are needed as input for the estimation algorithm. With every change of input arterial properties, the error in the blood pressure estimation rises, thus a periodic calibration procedure is needed for error minimization. Recent research is focused on simplified constant arterial properties which are not constant over time and uses only linear model based on initial measurement. The elaboration of continuous calibration procedures, independent of recalibration measurement, is the key to improving the accuracy and robustness of noninvasive continuous blood pressure estimation. However, most models in literature are based on linear approximation and we discuss here the need for more complete calibration models.","PeriodicalId":39235,"journal":{"name":"IEEE Reviews in Biomedical Engineering","volume":"15 ","pages":"138-151"},"PeriodicalIF":17.2000,"publicationDate":"2021-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"30","resultStr":"{\"title\":\"Noninvasive Continuous Blood Pressure Estimation From Pulse Transit Time: A Review of the Calibration Models\",\"authors\":\"Daniel Barvik;Martin Cerny;Marek Penhaker;Norbert Noury\",\"doi\":\"10.1109/RBME.2021.3109643\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Noninvasive continuous blood pressure estimation is a promising alternative to minimally invasive blood pressure measurement using cuff and invasive catheter measurement, because it opens the way to both long-term and continuous blood pressure monitoring in ecological situation. The most current estimation algorithm is based on pulse transit time measurement where at least two measured signals need to be acquired. From the pulse transit time values, it is possible to estimate the continuous blood pressure for each cardiac cycle. This measurement highly depends on arterial properties which are not easily accessible with common measurement techniques; but these properties are needed as input for the estimation algorithm. With every change of input arterial properties, the error in the blood pressure estimation rises, thus a periodic calibration procedure is needed for error minimization. Recent research is focused on simplified constant arterial properties which are not constant over time and uses only linear model based on initial measurement. The elaboration of continuous calibration procedures, independent of recalibration measurement, is the key to improving the accuracy and robustness of noninvasive continuous blood pressure estimation. However, most models in literature are based on linear approximation and we discuss here the need for more complete calibration models.\",\"PeriodicalId\":39235,\"journal\":{\"name\":\"IEEE Reviews in Biomedical Engineering\",\"volume\":\"15 \",\"pages\":\"138-151\"},\"PeriodicalIF\":17.2000,\"publicationDate\":\"2021-09-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"30\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Reviews in Biomedical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/9530229/\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Reviews in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/9530229/","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Noninvasive Continuous Blood Pressure Estimation From Pulse Transit Time: A Review of the Calibration Models
Noninvasive continuous blood pressure estimation is a promising alternative to minimally invasive blood pressure measurement using cuff and invasive catheter measurement, because it opens the way to both long-term and continuous blood pressure monitoring in ecological situation. The most current estimation algorithm is based on pulse transit time measurement where at least two measured signals need to be acquired. From the pulse transit time values, it is possible to estimate the continuous blood pressure for each cardiac cycle. This measurement highly depends on arterial properties which are not easily accessible with common measurement techniques; but these properties are needed as input for the estimation algorithm. With every change of input arterial properties, the error in the blood pressure estimation rises, thus a periodic calibration procedure is needed for error minimization. Recent research is focused on simplified constant arterial properties which are not constant over time and uses only linear model based on initial measurement. The elaboration of continuous calibration procedures, independent of recalibration measurement, is the key to improving the accuracy and robustness of noninvasive continuous blood pressure estimation. However, most models in literature are based on linear approximation and we discuss here the need for more complete calibration models.
期刊介绍:
IEEE Reviews in Biomedical Engineering (RBME) serves as a platform to review the state-of-the-art and trends in the interdisciplinary field of biomedical engineering, which encompasses engineering, life sciences, and medicine. The journal aims to consolidate research and reviews for members of all IEEE societies interested in biomedical engineering. Recognizing the demand for comprehensive reviews among authors of various IEEE journals, RBME addresses this need by receiving, reviewing, and publishing scholarly works under one umbrella. It covers a broad spectrum, from historical to modern developments in biomedical engineering and the integration of technologies from various IEEE societies into the life sciences and medicine.