不同应用方法对Dentin早期通用胶粘剂粘接效果的影响。

IF 2.5 3区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Adhesive Dentistry Pub Date : 2021-10-01 DOI:10.3290/j.jad.b2000257
Munenori Yokoyama, Toshiki Takamizawa, Tomohiko Tamura, Yoshihiro Namura, Akimasa Tsujimoto, Wayne W Barkmeier, Mark A Latta, Masashi Miyazaki
{"title":"不同应用方法对Dentin早期通用胶粘剂粘接效果的影响。","authors":"Munenori Yokoyama,&nbsp;Toshiki Takamizawa,&nbsp;Tomohiko Tamura,&nbsp;Yoshihiro Namura,&nbsp;Akimasa Tsujimoto,&nbsp;Wayne W Barkmeier,&nbsp;Mark A Latta,&nbsp;Masashi Miyazaki","doi":"10.3290/j.jad.b2000257","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the changes in the dentin bond strengths of universal adhesives during the early phase and evaluate the effect of a double-layer adhesive application on the performance of the dentin bond.</p><p><strong>Materials and methods: </strong>Three universal adhesives and a two-step self-etch adhesive were employed to ascertain the shear bond strengths (SBS) of specimens to bovine dentin with the use of the etch-and-rinse or self-etch mode. The specimens were further divided into two groups based on adhesive application in a single or a double layer. The bonded specimens were stored in distilled water at 37°C for 5 min or 1, 6, 12, or 24 h prior to SBS measurement and the adhesives' Knoop hardness number (KHN).</p><p><strong>Results: </strong>All the adhesives showed increased SBS with prolonged storage periods regardless of the adhesive layer (single or double) or etching mode. Most universal adhesives in the double adhesive layer groups showed significantly higher SBS than single adhesive layer groups for the same storage period. All the adhesives also showed increased KHN with increased storage period.</p><p><strong>Conclusion: </strong>The SBS and KHN values of the adhesives increased with increasing storage duration over a 24-h period. Double adhesive layer application mediated increased dentin bond strength in the early phase.</p>","PeriodicalId":55604,"journal":{"name":"Journal of Adhesive Dentistry","volume":"23 5","pages":"447-459"},"PeriodicalIF":2.5000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Influence of Different Application Methods on the Bonding Effectiveness of Universal Adhesives to Dentin in the Early Phase.\",\"authors\":\"Munenori Yokoyama,&nbsp;Toshiki Takamizawa,&nbsp;Tomohiko Tamura,&nbsp;Yoshihiro Namura,&nbsp;Akimasa Tsujimoto,&nbsp;Wayne W Barkmeier,&nbsp;Mark A Latta,&nbsp;Masashi Miyazaki\",\"doi\":\"10.3290/j.jad.b2000257\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To investigate the changes in the dentin bond strengths of universal adhesives during the early phase and evaluate the effect of a double-layer adhesive application on the performance of the dentin bond.</p><p><strong>Materials and methods: </strong>Three universal adhesives and a two-step self-etch adhesive were employed to ascertain the shear bond strengths (SBS) of specimens to bovine dentin with the use of the etch-and-rinse or self-etch mode. The specimens were further divided into two groups based on adhesive application in a single or a double layer. The bonded specimens were stored in distilled water at 37°C for 5 min or 1, 6, 12, or 24 h prior to SBS measurement and the adhesives' Knoop hardness number (KHN).</p><p><strong>Results: </strong>All the adhesives showed increased SBS with prolonged storage periods regardless of the adhesive layer (single or double) or etching mode. Most universal adhesives in the double adhesive layer groups showed significantly higher SBS than single adhesive layer groups for the same storage period. All the adhesives also showed increased KHN with increased storage period.</p><p><strong>Conclusion: </strong>The SBS and KHN values of the adhesives increased with increasing storage duration over a 24-h period. Double adhesive layer application mediated increased dentin bond strength in the early phase.</p>\",\"PeriodicalId\":55604,\"journal\":{\"name\":\"Journal of Adhesive Dentistry\",\"volume\":\"23 5\",\"pages\":\"447-459\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2021-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Adhesive Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3290/j.jad.b2000257\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Adhesive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3290/j.jad.b2000257","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 9

摘要

目的:探讨通用胶粘剂早期牙本质粘结强度的变化,并评价双层adhesive应用on对牙本质粘结性能的影响。材料和方法:采用三种通用胶粘剂和一种两步自蚀刻胶粘剂,采用蚀刻-冲洗或自蚀刻方式测定试样与牛牙本质的剪切粘接强度(SBS)。根据adhesive应用[in]将样品进一步分为单层或双层两组。粘合后的样品在37°C的蒸馏水中保存5分钟或1、6、12或24小时,然后SBS测量and胶粘剂的努氏硬度值(KHN)。结果:所有胶粘剂的SBS均增加with,无论胶粘剂单层或双层或蚀刻方式均延长了储存时间。双胶层组中大多数通用胶粘剂的SBS均显著高于than单胶粘剂组for。所有胶粘剂also的KHN均随贮存时间的延长而增加。结论:increasing储存时间≥24h时,黏合剂的SBS和KHN值≥increased。双胶层应用mediated增加了the前期牙本质结合强度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Influence of Different Application Methods on the Bonding Effectiveness of Universal Adhesives to Dentin in the Early Phase.

Purpose: To investigate the changes in the dentin bond strengths of universal adhesives during the early phase and evaluate the effect of a double-layer adhesive application on the performance of the dentin bond.

Materials and methods: Three universal adhesives and a two-step self-etch adhesive were employed to ascertain the shear bond strengths (SBS) of specimens to bovine dentin with the use of the etch-and-rinse or self-etch mode. The specimens were further divided into two groups based on adhesive application in a single or a double layer. The bonded specimens were stored in distilled water at 37°C for 5 min or 1, 6, 12, or 24 h prior to SBS measurement and the adhesives' Knoop hardness number (KHN).

Results: All the adhesives showed increased SBS with prolonged storage periods regardless of the adhesive layer (single or double) or etching mode. Most universal adhesives in the double adhesive layer groups showed significantly higher SBS than single adhesive layer groups for the same storage period. All the adhesives also showed increased KHN with increased storage period.

Conclusion: The SBS and KHN values of the adhesives increased with increasing storage duration over a 24-h period. Double adhesive layer application mediated increased dentin bond strength in the early phase.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Adhesive Dentistry
Journal of Adhesive Dentistry 医学-牙科与口腔外科
CiteScore
5.20
自引率
6.10%
发文量
44
审稿时长
6-12 weeks
期刊介绍: New materials and applications for adhesion are profoundly changing the way dentistry is delivered. Bonding techniques, which have long been restricted to the tooth hard tissues, enamel, and dentin, have obvious applications in operative and preventive dentistry, as well as in esthetic and pediatric dentistry, prosthodontics, and orthodontics. The current development of adhesive techniques for soft tissues and slow-releasing agents will expand applications to include periodontics and oral surgery. Scientifically sound, peer-reviewed articles explore the latest innovations in these emerging fields.
期刊最新文献
Preheated Composite as an Alternative for Bonding Feldspathic and Hybrid Ceramics: A Microshear Bond Strength Study. Fourteen-year Clinical Performance of a HEMA-free One-step Self-etch Adhesive in Non-carious Cervical Lesions. Three-year Clinical Performance of a Universal Adhesive in Non-Carious Cervical Lesions. Effects of Surface Treatment and Thermocycling on the Shear Bond Strength of Zirconia-Reinforced Lithium Silicate Ceramic. Effect of Carbodiimide (EDC) on the Bond Strength Longevity of Epoxy Resin-based Endodontic Sealer to Root Dentin: An In-Vitro Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1