追踪人体运动的惯性测量单元的有效性:系统综述。

IF 2 3区 医学 Q3 ENGINEERING, BIOMEDICAL Sports Biomechanics Pub Date : 2024-11-01 Epub Date: 2021-10-26 DOI:10.1080/14763141.2021.1990383
John Ghattas, Danielle N Jarvis
{"title":"追踪人体运动的惯性测量单元的有效性:系统综述。","authors":"John Ghattas, Danielle N Jarvis","doi":"10.1080/14763141.2021.1990383","DOIUrl":null,"url":null,"abstract":"<p><p>Human motion is often tracked using three-dimensional video motion tracking systems, which have demonstrated high levels of validity. More recently, inertial measurement units (IMUs) have been used to measure human movement due to their ease of access and application. The purpose of this study was to systematically review the literature regarding the validity of inertial sensor systems when being used to track human motion. Four electronic databases were used for the search, and eleven studies were included in the final review. IMUs have a high level of agreement with motion capture systems in the frontal and sagittal planes, measured with root mean square error (RMSE), intraclass correlation coefficient, and Pearson's correlation. However, the transverse or rotational planes began to show large discrepancies in joint angles between systems. Furthermore, as the intensity of the task being measured increased, the RMSE values began to get much larger. Currently, the use of accelerometers and inertial sensor systems has limited application in the assessment of human motion, but if the precision and processing of IMU devices improves further, it could provide researchers an opportunity to collect data in less synthetic environments, as well as improve ease of access to biomechanically analyse human movement.</p>","PeriodicalId":49482,"journal":{"name":"Sports Biomechanics","volume":" ","pages":"1853-1866"},"PeriodicalIF":2.0000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validity of inertial measurement units for tracking human motion: a systematic review.\",\"authors\":\"John Ghattas, Danielle N Jarvis\",\"doi\":\"10.1080/14763141.2021.1990383\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Human motion is often tracked using three-dimensional video motion tracking systems, which have demonstrated high levels of validity. More recently, inertial measurement units (IMUs) have been used to measure human movement due to their ease of access and application. The purpose of this study was to systematically review the literature regarding the validity of inertial sensor systems when being used to track human motion. Four electronic databases were used for the search, and eleven studies were included in the final review. IMUs have a high level of agreement with motion capture systems in the frontal and sagittal planes, measured with root mean square error (RMSE), intraclass correlation coefficient, and Pearson's correlation. However, the transverse or rotational planes began to show large discrepancies in joint angles between systems. Furthermore, as the intensity of the task being measured increased, the RMSE values began to get much larger. Currently, the use of accelerometers and inertial sensor systems has limited application in the assessment of human motion, but if the precision and processing of IMU devices improves further, it could provide researchers an opportunity to collect data in less synthetic environments, as well as improve ease of access to biomechanically analyse human movement.</p>\",\"PeriodicalId\":49482,\"journal\":{\"name\":\"Sports Biomechanics\",\"volume\":\" \",\"pages\":\"1853-1866\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sports Biomechanics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/14763141.2021.1990383\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/10/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sports Biomechanics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/14763141.2021.1990383","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/10/26 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

人类运动通常使用三维视频运动跟踪系统进行跟踪,该系统已被证明具有很高的有效性。最近,惯性测量单元(IMU)因其易于获取和应用而被用于测量人体运动。本研究的目的是系统回顾有关惯性传感器系统用于追踪人体运动时的有效性的文献。本研究使用了四个电子数据库进行搜索,最终纳入了 11 项研究。根据均方根误差 (RMSE)、类内相关系数和皮尔逊相关性测量,在正面和矢状平面上,惯性传感器与运动捕捉系统具有很高的一致性。然而,在横向或旋转平面上,系统间的关节角度开始出现巨大差异。此外,随着测量任务强度的增加,均方根误差值也开始变得更大。目前,加速度计和惯性传感器系统在人类运动评估中的应用有限,但如果 IMU 设备的精度和处理能力进一步提高,研究人员就有机会在更少的合成环境中收集数据,并更容易对人类运动进行生物力学分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Validity of inertial measurement units for tracking human motion: a systematic review.

Human motion is often tracked using three-dimensional video motion tracking systems, which have demonstrated high levels of validity. More recently, inertial measurement units (IMUs) have been used to measure human movement due to their ease of access and application. The purpose of this study was to systematically review the literature regarding the validity of inertial sensor systems when being used to track human motion. Four electronic databases were used for the search, and eleven studies were included in the final review. IMUs have a high level of agreement with motion capture systems in the frontal and sagittal planes, measured with root mean square error (RMSE), intraclass correlation coefficient, and Pearson's correlation. However, the transverse or rotational planes began to show large discrepancies in joint angles between systems. Furthermore, as the intensity of the task being measured increased, the RMSE values began to get much larger. Currently, the use of accelerometers and inertial sensor systems has limited application in the assessment of human motion, but if the precision and processing of IMU devices improves further, it could provide researchers an opportunity to collect data in less synthetic environments, as well as improve ease of access to biomechanically analyse human movement.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Sports Biomechanics
Sports Biomechanics 医学-工程:生物医学
CiteScore
5.70
自引率
9.10%
发文量
135
审稿时长
>12 weeks
期刊介绍: Sports Biomechanics is the Thomson Reuters listed scientific journal of the International Society of Biomechanics in Sports (ISBS). The journal sets out to generate knowledge to improve human performance and reduce the incidence of injury, and to communicate this knowledge to scientists, coaches, clinicians, teachers, and participants. The target performance realms include not only the conventional areas of sports and exercise, but also fundamental motor skills and other highly specialized human movements such as dance (both sport and artistic). Sports Biomechanics is unique in its emphasis on a broad biomechanical spectrum of human performance including, but not limited to, technique, skill acquisition, training, strength and conditioning, exercise, coaching, teaching, equipment, modeling and simulation, measurement, and injury prevention and rehabilitation. As well as maintaining scientific rigour, there is a strong editorial emphasis on ''reader friendliness''. By emphasising the practical implications and applications of research, the journal seeks to benefit practitioners directly. Sports Biomechanics publishes papers in four sections: Original Research, Reviews, Teaching, and Methods and Theoretical Perspectives.
期刊最新文献
Measuring pole forces in seated shot put: a case study. Markerless motion capture in sport: panacea or Pandora's box? Association between T2 relaxation time and biomechanical loading of the anterior cruciate ligament in healthy individuals. A comparison of maximal isometric force in the first pull, transition and second pull of the clean and their contribution to predict performance in national and international level weightlifters. Angular motion of the thorax during the golf swing: a comparison of two orientation angle sequences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1