新型多孔钛支架与骨重建部位植入物的骨结合。

IF 1 Q3 DENTISTRY, ORAL SURGERY & MEDICINE eJournal of Oral Maxillofacial Research Pub Date : 2021-09-30 eCollection Date: 2021-07-01 DOI:10.5037/jomr.2021.12304
Kazuya Doi, Reiko Kobatake, Yusuke Makihara, Yoshifumi Oki, Hanako Umehara, Takayasu Kubo, Kazuhiro Tsuga
{"title":"新型多孔钛支架与骨重建部位植入物的骨结合。","authors":"Kazuya Doi, Reiko Kobatake, Yusuke Makihara, Yoshifumi Oki, Hanako Umehara, Takayasu Kubo, Kazuhiro Tsuga","doi":"10.5037/jomr.2021.12304","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Porous titanium is used for the reconstruction of large bone defects due to its excellent mechanical strength. The quality of osseointegration of implants placed in bone reconstructed with porous titanium is unknown. The purpose of this <i>in vivo</i> study was to evaluate the osseointegration of implants at sites reconstructed using porous titanium.</p><p><strong>Material and methods: </strong>Hollow porous titanium (Ti) (outer-diameter 6 mm, inner-diameter 2 mm, length 4 mm, 85% porosity) and similar-sized porous hydroxyapatite (porous HA: 75% porosity) samples were prepared and implanted in 6 New Zealand white rabbit femurs. Four weeks later, an implant bed was created to receive a Ti implant (diameter 2 mm, length 4 mm). An implant placed at a pristine bone site served as the control. Four weeks later, histological and histomorphometric evaluations of the test and control sites were conducted.</p><p><strong>Results: </strong>Osseointegration was observed in all groups. There was no significant difference in the bone formation ratio and bone-implant contact (BIC) ratio across all groups for the whole area. At the cancellous bone area of the bone defect, superior bone formation ratio and BIC ratio were observed with porous Ti and porous HA compared to the control (bone formation ratio: control 1.8 [SD 3]%, HA 23 [SD 3]%, Ti 23.6 [SD 5]%; BIC ratio: control 5.4 [SD 5.3]%, HA 28.9 [SD 10.7]%, Ti 41.6 [SD 14]%). Porous Ti demonstrated good osteoconduction and osseointegration abilities, similar to porous HA.</p><p><strong>Conclusions: </strong>To our knowledge, this is the first report of implant treatment after preliminary bone reconstruction using a titanium biomaterial. Porous titanium is a suitable material for bone reconstruction before implant treatment in load-bearing areas that allow subsequent prosthetic treatment.</p>","PeriodicalId":53254,"journal":{"name":"eJournal of Oral Maxillofacial Research","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2021-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/45/b6/jomr-12-e4.PMC8577583.pdf","citationCount":"0","resultStr":"{\"title\":\"Osseointegration Aspects of Implants at the Bone Reconstruction Site by a Novel Porous Titanium Scaffold.\",\"authors\":\"Kazuya Doi, Reiko Kobatake, Yusuke Makihara, Yoshifumi Oki, Hanako Umehara, Takayasu Kubo, Kazuhiro Tsuga\",\"doi\":\"10.5037/jomr.2021.12304\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Porous titanium is used for the reconstruction of large bone defects due to its excellent mechanical strength. The quality of osseointegration of implants placed in bone reconstructed with porous titanium is unknown. The purpose of this <i>in vivo</i> study was to evaluate the osseointegration of implants at sites reconstructed using porous titanium.</p><p><strong>Material and methods: </strong>Hollow porous titanium (Ti) (outer-diameter 6 mm, inner-diameter 2 mm, length 4 mm, 85% porosity) and similar-sized porous hydroxyapatite (porous HA: 75% porosity) samples were prepared and implanted in 6 New Zealand white rabbit femurs. Four weeks later, an implant bed was created to receive a Ti implant (diameter 2 mm, length 4 mm). An implant placed at a pristine bone site served as the control. Four weeks later, histological and histomorphometric evaluations of the test and control sites were conducted.</p><p><strong>Results: </strong>Osseointegration was observed in all groups. There was no significant difference in the bone formation ratio and bone-implant contact (BIC) ratio across all groups for the whole area. At the cancellous bone area of the bone defect, superior bone formation ratio and BIC ratio were observed with porous Ti and porous HA compared to the control (bone formation ratio: control 1.8 [SD 3]%, HA 23 [SD 3]%, Ti 23.6 [SD 5]%; BIC ratio: control 5.4 [SD 5.3]%, HA 28.9 [SD 10.7]%, Ti 41.6 [SD 14]%). Porous Ti demonstrated good osteoconduction and osseointegration abilities, similar to porous HA.</p><p><strong>Conclusions: </strong>To our knowledge, this is the first report of implant treatment after preliminary bone reconstruction using a titanium biomaterial. Porous titanium is a suitable material for bone reconstruction before implant treatment in load-bearing areas that allow subsequent prosthetic treatment.</p>\",\"PeriodicalId\":53254,\"journal\":{\"name\":\"eJournal of Oral Maxillofacial Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2021-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/45/b6/jomr-12-e4.PMC8577583.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"eJournal of Oral Maxillofacial Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5037/jomr.2021.12304\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/7/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"eJournal of Oral Maxillofacial Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5037/jomr.2021.12304","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/7/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:多孔钛因其出色的机械强度而被用于重建大面积骨缺损。在使用多孔钛重建的骨中植入种植体的骨结合质量尚不清楚。材料和方法:制备空心多孔钛(Ti)(外径 6 毫米,内径 2 毫米,长度 4 毫米,孔隙率 85%)和类似大小的多孔羟基磷灰石(多孔 HA:孔隙率 75%)样品,并将其植入 6 只新西兰白兔的股骨中。四周后,创建植入床,以植入钛植入体(直径 2 毫米,长 4 毫米)。在原始骨部位植入的植入体作为对照。四周后,对试验部位和对照部位进行组织学和组织形态计量学评估:结果:所有组均观察到骨结合。在整个区域,各组的骨形成比率和骨与种植体接触比率(BIC)均无明显差异。在骨缺损的松质骨区域,与对照组相比,多孔 Ti 和多孔 HA 的骨形成比和 BIC 比更优(骨形成比:对照组 1.8 [SD 3]%,HA 23 [SD 3]%,Ti 23.6 [SD 5]%;BIC 比:对照组 5.4 [SD 5.3]%,HA 28.9 [SD 10.7]%,Ti 41.6 [SD 14]%)。多孔钛表现出良好的骨传导和骨结合能力,与多孔 HA 相似:据我们所知,这是第一份使用钛生物材料进行初步骨重建后种植治疗的报告。多孔钛是一种适用于承重区域种植治疗前骨重建的材料,可用于后续修复治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Osseointegration Aspects of Implants at the Bone Reconstruction Site by a Novel Porous Titanium Scaffold.

Objectives: Porous titanium is used for the reconstruction of large bone defects due to its excellent mechanical strength. The quality of osseointegration of implants placed in bone reconstructed with porous titanium is unknown. The purpose of this in vivo study was to evaluate the osseointegration of implants at sites reconstructed using porous titanium.

Material and methods: Hollow porous titanium (Ti) (outer-diameter 6 mm, inner-diameter 2 mm, length 4 mm, 85% porosity) and similar-sized porous hydroxyapatite (porous HA: 75% porosity) samples were prepared and implanted in 6 New Zealand white rabbit femurs. Four weeks later, an implant bed was created to receive a Ti implant (diameter 2 mm, length 4 mm). An implant placed at a pristine bone site served as the control. Four weeks later, histological and histomorphometric evaluations of the test and control sites were conducted.

Results: Osseointegration was observed in all groups. There was no significant difference in the bone formation ratio and bone-implant contact (BIC) ratio across all groups for the whole area. At the cancellous bone area of the bone defect, superior bone formation ratio and BIC ratio were observed with porous Ti and porous HA compared to the control (bone formation ratio: control 1.8 [SD 3]%, HA 23 [SD 3]%, Ti 23.6 [SD 5]%; BIC ratio: control 5.4 [SD 5.3]%, HA 28.9 [SD 10.7]%, Ti 41.6 [SD 14]%). Porous Ti demonstrated good osteoconduction and osseointegration abilities, similar to porous HA.

Conclusions: To our knowledge, this is the first report of implant treatment after preliminary bone reconstruction using a titanium biomaterial. Porous titanium is a suitable material for bone reconstruction before implant treatment in load-bearing areas that allow subsequent prosthetic treatment.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
19
审稿时长
12 weeks
期刊最新文献
Outcome Difference between Short and Longer Dental Implants Placed Simultaneously with Alveolar Bone Augmentation: a Systematic Review and Meta-Analysis. The Use of Platelet-Rich Fibrin in Sinus Floor Augmentation Surgery: a Systematic Review. Attitudes of Oral Surgeons and Periodontists towards Immediate Dental Implant Placement. Can CAPRIN-1 Be Responsible for the Recurrence Potential of Odontogenic Keratocysts? Dental Implant Placement in the Maxilla Following Ridge Augmentation with Free Iliac Bone Graft and Oral Rehabilitation with Fixed Prosthesis: a Three-Year Follow-Up Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1