Mini-iFT确认使用光固化修复复合材料具有优越的粘接性能。

IF 2.5 3区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Adhesive Dentistry Pub Date : 2021-12-03 DOI:10.3290/j.jad.b2287755
Chloe M F Hardy, Violette Landreau, Margaux Valassis, Ben Mercelis, Jan De Munck, Bart Van Meerbeek, Julian Leprince
{"title":"Mini-iFT确认使用光固化修复复合材料具有优越的粘接性能。","authors":"Chloe M F Hardy,&nbsp;Violette Landreau,&nbsp;Margaux Valassis,&nbsp;Ben Mercelis,&nbsp;Jan De Munck,&nbsp;Bart Van Meerbeek,&nbsp;Julian Leprince","doi":"10.3290/j.jad.b2287755","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To validate the rationale of using a conventional light-curing resin-based composite (RBC) to lute thick indirect restorations by measuring mini-interfacial fracture toughness (mini-iFT).</p><p><strong>Materials and methods: </strong>Freshly exposed dentin of extracted third molars (n = 64) was immediately sealed with a thin layer of an experimental RBC with a 50 wt% or 75 wt% (IDS) filler load. Two- or 6-mm-thick CAD/CAM composite blocks were luted onto IDS using either pre-heated light-cure or dual-cure luting RBC, with the latter having served as control. Samples were cut into sticks, upon which a notch was prepared at the interface between IDS and luting RBC, prior to being submitted to a 4-point bending test to determine mini-iFT. The results were analyzed using a mixed linear model (LME). Failure mode at the fractured interface was determined using scanning electron microscopy (SEM).</p><p><strong>Results: </strong>LME revealed that mini-iFT was not significantly affected by the composite block thickness (p = 0.39), but by the luting RBC (p < 0.0001) and the IDS RBC filler load (p = 0.0011). Mini-iFT was higher with 50 wt% filler-loaded RBC IDS and when luted using the light-curing RBC.</p><p><strong>Conclusion: </strong>This work provides the proof of concept that 2- and 6-mm-thick indirect restorations can safely be adhesively luted with pre-heated conventional light-cure RBC under controlled light-irradiation conditions. This strategy even seems beneficial in terms of mini-iFT compared to using a dual-cure luting RBC. IDS with lower filler content also appeared more favorable.</p>","PeriodicalId":55604,"journal":{"name":"Journal of Adhesive Dentistry","volume":"23 6","pages":"539-548"},"PeriodicalIF":2.5000,"publicationDate":"2021-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Mini-iFT Confirms Superior Adhesive Luting Performance using Light-curing Restorative Composites.\",\"authors\":\"Chloe M F Hardy,&nbsp;Violette Landreau,&nbsp;Margaux Valassis,&nbsp;Ben Mercelis,&nbsp;Jan De Munck,&nbsp;Bart Van Meerbeek,&nbsp;Julian Leprince\",\"doi\":\"10.3290/j.jad.b2287755\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To validate the rationale of using a conventional light-curing resin-based composite (RBC) to lute thick indirect restorations by measuring mini-interfacial fracture toughness (mini-iFT).</p><p><strong>Materials and methods: </strong>Freshly exposed dentin of extracted third molars (n = 64) was immediately sealed with a thin layer of an experimental RBC with a 50 wt% or 75 wt% (IDS) filler load. Two- or 6-mm-thick CAD/CAM composite blocks were luted onto IDS using either pre-heated light-cure or dual-cure luting RBC, with the latter having served as control. Samples were cut into sticks, upon which a notch was prepared at the interface between IDS and luting RBC, prior to being submitted to a 4-point bending test to determine mini-iFT. The results were analyzed using a mixed linear model (LME). Failure mode at the fractured interface was determined using scanning electron microscopy (SEM).</p><p><strong>Results: </strong>LME revealed that mini-iFT was not significantly affected by the composite block thickness (p = 0.39), but by the luting RBC (p < 0.0001) and the IDS RBC filler load (p = 0.0011). Mini-iFT was higher with 50 wt% filler-loaded RBC IDS and when luted using the light-curing RBC.</p><p><strong>Conclusion: </strong>This work provides the proof of concept that 2- and 6-mm-thick indirect restorations can safely be adhesively luted with pre-heated conventional light-cure RBC under controlled light-irradiation conditions. This strategy even seems beneficial in terms of mini-iFT compared to using a dual-cure luting RBC. IDS with lower filler content also appeared more favorable.</p>\",\"PeriodicalId\":55604,\"journal\":{\"name\":\"Journal of Adhesive Dentistry\",\"volume\":\"23 6\",\"pages\":\"539-548\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2021-12-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Adhesive Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3290/j.jad.b2287755\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Adhesive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3290/j.jad.b2287755","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

摘要

目的:通过测量微界面断裂韧性(mini-iFT)来验证使用传统light-curing树脂基复合材料(RBC)进行厚间接修复的合理性。材料和方法:取出的第三磨牙(n = 64)新鲜暴露的牙本质立即用实验红细胞with薄层密封,填充50 wt%或75 wt% (IDS) >。Two- or 6-mm-thick CAD/CAM复合材料blocks were使用预热光固化或双固化固化rbc_连接到IDS上,后者作为对照。将样品切成棒状,在IDS和凹槽rbc_之间的界面处准备一个缺口,然后提交a 4点弯曲test以确定mini-iFT。使用混合线性模型(LME)对结果进行分析。利用扫描电镜(SEM)确定了断裂界面的破坏模式。结果:LME显示that mini-iFT不受复合块厚度(p = 0.39)影响,但受the luting RBC (p < 0.0001)和IDS RBC填充物负荷(p = 0.0011)影响。当使用light-curing RBC时,Mini-iFT更高。结论:本研究提供了2-和6-mm-thick间接修复体在可控光照射条件下可以安全地粘附于传统光固化RBC的概念证明。这种策略甚至在mini-iFT方面比使用双固化的RBC更有利。填料含量较低的IDS也出现较多favorable。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Mini-iFT Confirms Superior Adhesive Luting Performance using Light-curing Restorative Composites.

Purpose: To validate the rationale of using a conventional light-curing resin-based composite (RBC) to lute thick indirect restorations by measuring mini-interfacial fracture toughness (mini-iFT).

Materials and methods: Freshly exposed dentin of extracted third molars (n = 64) was immediately sealed with a thin layer of an experimental RBC with a 50 wt% or 75 wt% (IDS) filler load. Two- or 6-mm-thick CAD/CAM composite blocks were luted onto IDS using either pre-heated light-cure or dual-cure luting RBC, with the latter having served as control. Samples were cut into sticks, upon which a notch was prepared at the interface between IDS and luting RBC, prior to being submitted to a 4-point bending test to determine mini-iFT. The results were analyzed using a mixed linear model (LME). Failure mode at the fractured interface was determined using scanning electron microscopy (SEM).

Results: LME revealed that mini-iFT was not significantly affected by the composite block thickness (p = 0.39), but by the luting RBC (p < 0.0001) and the IDS RBC filler load (p = 0.0011). Mini-iFT was higher with 50 wt% filler-loaded RBC IDS and when luted using the light-curing RBC.

Conclusion: This work provides the proof of concept that 2- and 6-mm-thick indirect restorations can safely be adhesively luted with pre-heated conventional light-cure RBC under controlled light-irradiation conditions. This strategy even seems beneficial in terms of mini-iFT compared to using a dual-cure luting RBC. IDS with lower filler content also appeared more favorable.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Adhesive Dentistry
Journal of Adhesive Dentistry 医学-牙科与口腔外科
CiteScore
5.20
自引率
6.10%
发文量
44
审稿时长
6-12 weeks
期刊介绍: New materials and applications for adhesion are profoundly changing the way dentistry is delivered. Bonding techniques, which have long been restricted to the tooth hard tissues, enamel, and dentin, have obvious applications in operative and preventive dentistry, as well as in esthetic and pediatric dentistry, prosthodontics, and orthodontics. The current development of adhesive techniques for soft tissues and slow-releasing agents will expand applications to include periodontics and oral surgery. Scientifically sound, peer-reviewed articles explore the latest innovations in these emerging fields.
期刊最新文献
Preheated Composite as an Alternative for Bonding Feldspathic and Hybrid Ceramics: A Microshear Bond Strength Study. Fourteen-year Clinical Performance of a HEMA-free One-step Self-etch Adhesive in Non-carious Cervical Lesions. Three-year Clinical Performance of a Universal Adhesive in Non-Carious Cervical Lesions. Effects of Surface Treatment and Thermocycling on the Shear Bond Strength of Zirconia-Reinforced Lithium Silicate Ceramic. Effect of Carbodiimide (EDC) on the Bond Strength Longevity of Epoxy Resin-based Endodontic Sealer to Root Dentin: An In-Vitro Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1