Alexander J Volkmar, Robert Elrod, Justin W Vickery, Charlie C Yang, Gregory G Polkowski, J Ryan Martin
{"title":"初级全膝关节置换术中的关键替代植入物。","authors":"Alexander J Volkmar, Robert Elrod, Justin W Vickery, Charlie C Yang, Gregory G Polkowski, J Ryan Martin","doi":"10.1155/2022/2676715","DOIUrl":null,"url":null,"abstract":"<p><p>The use of cruciate substituting (CS) total knee replacement has been increasing in popularity. There are numerous factors that have likely contributed to this expansion. The CS philosophy incorporates the ease of use commonly cited by advocates of the posterior stabilized (PS) total knee design with the bone preservation associated with a cruciate retaining (CR) design. The ultra-congruent highly cross-linked polyethylene liner increases stability without an appreciable change in wear. Furthermore, balancing the flexion and extension gaps does not require \"titrating\" the posterior cruciate ligament, improving the user-friendliness. This paper reviews the nuances of this implant design compared to PS and CR designs as well as provides surgical technique recommendations/considerations.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2022-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8803465/pdf/","citationCount":"2","resultStr":"{\"title\":\"Cruciate Substituting Implants in Primary Total Knee Arthroplasty.\",\"authors\":\"Alexander J Volkmar, Robert Elrod, Justin W Vickery, Charlie C Yang, Gregory G Polkowski, J Ryan Martin\",\"doi\":\"10.1155/2022/2676715\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The use of cruciate substituting (CS) total knee replacement has been increasing in popularity. There are numerous factors that have likely contributed to this expansion. The CS philosophy incorporates the ease of use commonly cited by advocates of the posterior stabilized (PS) total knee design with the bone preservation associated with a cruciate retaining (CR) design. The ultra-congruent highly cross-linked polyethylene liner increases stability without an appreciable change in wear. Furthermore, balancing the flexion and extension gaps does not require \\\"titrating\\\" the posterior cruciate ligament, improving the user-friendliness. This paper reviews the nuances of this implant design compared to PS and CR designs as well as provides surgical technique recommendations/considerations.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2022-01-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8803465/pdf/\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2022/2676715\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2022/2676715","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Cruciate Substituting Implants in Primary Total Knee Arthroplasty.
The use of cruciate substituting (CS) total knee replacement has been increasing in popularity. There are numerous factors that have likely contributed to this expansion. The CS philosophy incorporates the ease of use commonly cited by advocates of the posterior stabilized (PS) total knee design with the bone preservation associated with a cruciate retaining (CR) design. The ultra-congruent highly cross-linked polyethylene liner increases stability without an appreciable change in wear. Furthermore, balancing the flexion and extension gaps does not require "titrating" the posterior cruciate ligament, improving the user-friendliness. This paper reviews the nuances of this implant design compared to PS and CR designs as well as provides surgical technique recommendations/considerations.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.