新型不含hema的两步自蚀刻胶能否提高牙本质粘接耐久性和边缘适应性?

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2021-12-03 DOI:10.3290/j.jad.b2288233
Antonin Tichy, Keiichi Hosaka, Yi Yang, Yutaro Motoyama, Yasunori Sumi, Masatoshi Nakajima, Junji Tagami
{"title":"新型不含hema的两步自蚀刻胶能否提高牙本质粘接耐久性和边缘适应性?","authors":"Antonin Tichy,&nbsp;Keiichi Hosaka,&nbsp;Yi Yang,&nbsp;Yutaro Motoyama,&nbsp;Yasunori Sumi,&nbsp;Masatoshi Nakajima,&nbsp;Junji Tagami","doi":"10.3290/j.jad.b2288233","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>A new two-step self-etch adhesive (2-SEA) free of hydrophilic monomers was evaluated. Its microtensile bond strength (µTBS) to dentin under various aging conditions, interfacial gap formation, water sorption/solubility, and formation of an acid-base resistant zone (ABRZ) were evaluated and compared with a gold-standard 2-SEA.</p><p><strong>Materials and methods: </strong>The new 2-SEA G2-Bond Universal (G2; GC) was compared to Clearfil SE Bond 2 (CSE2, Kuraray Noritake). Their µTBS to sound coronal dentin was tested after 1 week, 10,000 thermal cycles (TC), 20,000 TC, 6 months and 1 year. Failure mode was determined using scanning electron microscopy (SEM). Gap formation at the interface of 2-mm deep tapered cavities with an enamel border was observed using swept-source optical coherence tomography after 1 day, 1 week, 10,000 TC, and 20,000 TC. In addition, water sorption and solubility of the bonding agents was measured, and ABRZ formation was evaluated using SEM.</p><p><strong>Results: </strong>There was no significant difference in µTBS between G2 and CSE2 (p > 0.05), and the aging conditions had no significant effect on µTBS (p > 0.05). In all groups, cohesive failures prevailed (55%-95%). Interfacial gap formation was initially similar for both adhesives (p > 0.05), but G2 exhibited a significantly lower gap formation than CSE2 after TC (p < 0.05). The water sorption of G2 was significantly lower compared to CSE2 (p < 0.05), and their solubility was statistically similar (p > 0.05). ABRZ of similar thickness was observed with both adhesives.</p><p><strong>Conclusion: </strong>The new 2-SEA exhibited stable dentin bonding and increased hydrophobicity resulting from the absence of hydrophilic monomers.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":"23 6","pages":"505-512"},"PeriodicalIF":4.6000,"publicationDate":"2021-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Can a New HEMA-free Two-step Self-etch Adhesive Improve Dentin Bonding Durability and Marginal Adaptation?\",\"authors\":\"Antonin Tichy,&nbsp;Keiichi Hosaka,&nbsp;Yi Yang,&nbsp;Yutaro Motoyama,&nbsp;Yasunori Sumi,&nbsp;Masatoshi Nakajima,&nbsp;Junji Tagami\",\"doi\":\"10.3290/j.jad.b2288233\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>A new two-step self-etch adhesive (2-SEA) free of hydrophilic monomers was evaluated. Its microtensile bond strength (µTBS) to dentin under various aging conditions, interfacial gap formation, water sorption/solubility, and formation of an acid-base resistant zone (ABRZ) were evaluated and compared with a gold-standard 2-SEA.</p><p><strong>Materials and methods: </strong>The new 2-SEA G2-Bond Universal (G2; GC) was compared to Clearfil SE Bond 2 (CSE2, Kuraray Noritake). Their µTBS to sound coronal dentin was tested after 1 week, 10,000 thermal cycles (TC), 20,000 TC, 6 months and 1 year. Failure mode was determined using scanning electron microscopy (SEM). Gap formation at the interface of 2-mm deep tapered cavities with an enamel border was observed using swept-source optical coherence tomography after 1 day, 1 week, 10,000 TC, and 20,000 TC. In addition, water sorption and solubility of the bonding agents was measured, and ABRZ formation was evaluated using SEM.</p><p><strong>Results: </strong>There was no significant difference in µTBS between G2 and CSE2 (p > 0.05), and the aging conditions had no significant effect on µTBS (p > 0.05). In all groups, cohesive failures prevailed (55%-95%). Interfacial gap formation was initially similar for both adhesives (p > 0.05), but G2 exhibited a significantly lower gap formation than CSE2 after TC (p < 0.05). The water sorption of G2 was significantly lower compared to CSE2 (p < 0.05), and their solubility was statistically similar (p > 0.05). ABRZ of similar thickness was observed with both adhesives.</p><p><strong>Conclusion: </strong>The new 2-SEA exhibited stable dentin bonding and increased hydrophobicity resulting from the absence of hydrophilic monomers.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":\"23 6\",\"pages\":\"505-512\"},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2021-12-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3290/j.jad.b2288233\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3290/j.jad.b2288233","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 6

摘要

目的:研究一种不含亲水性单体的两步自蚀刻胶粘剂(2-SEA)。在各种老化条件下,对其与牙本质的微拉伸结合强度(µTBS)、界面间隙形成、吸水性/溶解度和耐酸碱区(ABRZ)的形成进行了评估,并与金标准2-SEA进行了比较。材料与方法:新型2-SEA G2- bond Universal (G2;GC)与Clearfil SE Bond 2 (CSE2, Kuraray Noritake)进行比较。分别在1周、1万次热循环(TC)、2万次热循环(TC)、6个月和1年后测试他们对健全冠状牙本质的µTBS。用扫描电子显微镜(SEM)确定了失效模式。在1天,1周,10,000 TC和20,000 TC后,使用扫描源光学相干断层扫描观察2 mm深锥形牙釉质边界界面的间隙形成。此外,还测量了粘结剂的吸水性和溶解度,并利用扫描电镜对ABRZ的形成进行了评价。结果:G2与CSE2之间µTBS差异无统计学意义(p > 0.05),衰老条件对µTBS无显著影响(p > 0.05)。在所有组中,内聚失败普遍存在(55%-95%)。两种粘接剂的界面间隙形成初始相似(p > 0.05),但G2在TC后的间隙形成明显低于CSE2 (p < 0.05)。与CSE2相比,G2的吸水率显著降低(p < 0.05),溶解度差异有统计学意义(p > 0.05)。两种胶粘剂的ABRZ厚度相近。结论:新的2-SEA具有稳定的牙本质键合,并且由于缺乏亲水性单体而增加了疏水性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Can a New HEMA-free Two-step Self-etch Adhesive Improve Dentin Bonding Durability and Marginal Adaptation?

Purpose: A new two-step self-etch adhesive (2-SEA) free of hydrophilic monomers was evaluated. Its microtensile bond strength (µTBS) to dentin under various aging conditions, interfacial gap formation, water sorption/solubility, and formation of an acid-base resistant zone (ABRZ) were evaluated and compared with a gold-standard 2-SEA.

Materials and methods: The new 2-SEA G2-Bond Universal (G2; GC) was compared to Clearfil SE Bond 2 (CSE2, Kuraray Noritake). Their µTBS to sound coronal dentin was tested after 1 week, 10,000 thermal cycles (TC), 20,000 TC, 6 months and 1 year. Failure mode was determined using scanning electron microscopy (SEM). Gap formation at the interface of 2-mm deep tapered cavities with an enamel border was observed using swept-source optical coherence tomography after 1 day, 1 week, 10,000 TC, and 20,000 TC. In addition, water sorption and solubility of the bonding agents was measured, and ABRZ formation was evaluated using SEM.

Results: There was no significant difference in µTBS between G2 and CSE2 (p > 0.05), and the aging conditions had no significant effect on µTBS (p > 0.05). In all groups, cohesive failures prevailed (55%-95%). Interfacial gap formation was initially similar for both adhesives (p > 0.05), but G2 exhibited a significantly lower gap formation than CSE2 after TC (p < 0.05). The water sorption of G2 was significantly lower compared to CSE2 (p < 0.05), and their solubility was statistically similar (p > 0.05). ABRZ of similar thickness was observed with both adhesives.

Conclusion: The new 2-SEA exhibited stable dentin bonding and increased hydrophobicity resulting from the absence of hydrophilic monomers.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1