Konstantins Plotnikovs, Jevgenijs Movcans, Leonid Solomin
{"title":"开放性胫骨骨折伴骨及软组织缺损的急性短缩:文献系统回顾。","authors":"Konstantins Plotnikovs, Jevgenijs Movcans, Leonid Solomin","doi":"10.5005/jp-journals-10080-1551","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The presence of massive soft tissue loss in open tibial fractures is a challenging problem. Acute limb shortening is an alternative solution in situations where the use of flaps is limited.</p><p><strong>Materials and methods: </strong>A review was conducted following the Preferred Reported Items for Systematic Reviews and Meta-analyses checklist (PRISMA) guidelines. A complete search of PubMed, EMBASE and MEDLINE was undertaken. Twenty-four articles related to closure of soft tissue defects through acute limb shortening were identified and included in this review.</p><p><strong>Results: </strong>All report on restoration of limb function without or with minimal residual shortening. The authors note a decrease in the need for microsurgery. The external fixation devices used for deformity correction after closure of the soft tissue defect by acute shortening, angulation and rotation were the Ilizarov apparatus and circular fixator hexapods mainly.</p><p><strong>Conclusion: </strong>Acute shortening is an alternative to microsurgical techniques. A ring external fixator is useful for restoring limb alignment after closing the soft tissue defect through creating a temporary deformity. The use of circular fixator hexapods can enable accurate correction of complex multicomponent deformities without the need to reassembly of individual correction units.</p><p><strong>How to cite this article: </strong>Plotnikovs K, Movcans J, Solomin L. Acute Shortening for Open Tibial Fractures with Bone and Soft Tissue Defects: Systematic Review of Literature. Strategies Trauma Limb Reconstr 2022;17(1):44-54.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/ec/d2/stlr-17-44.PMC9166261.pdf","citationCount":"2","resultStr":"{\"title\":\"Acute Shortening for Open Tibial Fractures with Bone and Soft Tissue Defects: Systematic Review of Literature.\",\"authors\":\"Konstantins Plotnikovs, Jevgenijs Movcans, Leonid Solomin\",\"doi\":\"10.5005/jp-journals-10080-1551\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The presence of massive soft tissue loss in open tibial fractures is a challenging problem. Acute limb shortening is an alternative solution in situations where the use of flaps is limited.</p><p><strong>Materials and methods: </strong>A review was conducted following the Preferred Reported Items for Systematic Reviews and Meta-analyses checklist (PRISMA) guidelines. A complete search of PubMed, EMBASE and MEDLINE was undertaken. Twenty-four articles related to closure of soft tissue defects through acute limb shortening were identified and included in this review.</p><p><strong>Results: </strong>All report on restoration of limb function without or with minimal residual shortening. The authors note a decrease in the need for microsurgery. The external fixation devices used for deformity correction after closure of the soft tissue defect by acute shortening, angulation and rotation were the Ilizarov apparatus and circular fixator hexapods mainly.</p><p><strong>Conclusion: </strong>Acute shortening is an alternative to microsurgical techniques. A ring external fixator is useful for restoring limb alignment after closing the soft tissue defect through creating a temporary deformity. The use of circular fixator hexapods can enable accurate correction of complex multicomponent deformities without the need to reassembly of individual correction units.</p><p><strong>How to cite this article: </strong>Plotnikovs K, Movcans J, Solomin L. Acute Shortening for Open Tibial Fractures with Bone and Soft Tissue Defects: Systematic Review of Literature. Strategies Trauma Limb Reconstr 2022;17(1):44-54.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/ec/d2/stlr-17-44.PMC9166261.pdf\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5005/jp-journals-10080-1551\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5005/jp-journals-10080-1551","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Acute Shortening for Open Tibial Fractures with Bone and Soft Tissue Defects: Systematic Review of Literature.
Introduction: The presence of massive soft tissue loss in open tibial fractures is a challenging problem. Acute limb shortening is an alternative solution in situations where the use of flaps is limited.
Materials and methods: A review was conducted following the Preferred Reported Items for Systematic Reviews and Meta-analyses checklist (PRISMA) guidelines. A complete search of PubMed, EMBASE and MEDLINE was undertaken. Twenty-four articles related to closure of soft tissue defects through acute limb shortening were identified and included in this review.
Results: All report on restoration of limb function without or with minimal residual shortening. The authors note a decrease in the need for microsurgery. The external fixation devices used for deformity correction after closure of the soft tissue defect by acute shortening, angulation and rotation were the Ilizarov apparatus and circular fixator hexapods mainly.
Conclusion: Acute shortening is an alternative to microsurgical techniques. A ring external fixator is useful for restoring limb alignment after closing the soft tissue defect through creating a temporary deformity. The use of circular fixator hexapods can enable accurate correction of complex multicomponent deformities without the need to reassembly of individual correction units.
How to cite this article: Plotnikovs K, Movcans J, Solomin L. Acute Shortening for Open Tibial Fractures with Bone and Soft Tissue Defects: Systematic Review of Literature. Strategies Trauma Limb Reconstr 2022;17(1):44-54.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.