人类失衡评价与修复的创新体系。

IF 1 Q3 OTORHINOLARYNGOLOGY Polish Journal of Otolaryngology Pub Date : 2022-03-08 DOI:10.5604/01.3001.0015.7927
Anna Gawrońska, Ewa Zamysłowska-Szmytke, Magdalena Janc, Rafal Kotas, Marek Kamiński, Paweł Marciniak, Wojciech Tylman, Sebastian Woźniak, Jan Napieralski, Bartosz Sakowicz, Anna Pajor, Oskar Rosiak, Anna Puzio, Weronika Lucas-Brot, Magdalena Józefowicz-Korczyńska
{"title":"人类失衡评价与修复的创新体系。","authors":"Anna Gawrońska,&nbsp;Ewa Zamysłowska-Szmytke,&nbsp;Magdalena Janc,&nbsp;Rafal Kotas,&nbsp;Marek Kamiński,&nbsp;Paweł Marciniak,&nbsp;Wojciech Tylman,&nbsp;Sebastian Woźniak,&nbsp;Jan Napieralski,&nbsp;Bartosz Sakowicz,&nbsp;Anna Pajor,&nbsp;Oskar Rosiak,&nbsp;Anna Puzio,&nbsp;Weronika Lucas-Brot,&nbsp;Magdalena Józefowicz-Korczyńska","doi":"10.5604/01.3001.0015.7927","DOIUrl":null,"url":null,"abstract":"<p><p>&lt;b&gt;Introduction:&lt;/b&gt; Mobile posturography is based on wearable inertial sensors; it allows to test static stability (static posturography) and gait disturbances. &lt;/br&gt; &lt;/br&gt; &lt;b&gt;Aim:&lt;/b&gt; The aim of this work was to present the results of research on the innovative MEDIPOST system used for diagnosis and rehabilitation of balance disorders. &lt;/br&gt; &lt;/br&gt; &lt;b&gt;Material and methods:&lt;/b&gt; Fourteen articles published in influenced foreign journals were presented and discussed. The deve-lopment and construction of the device was preceded by a literature review and methodological work. The Dizziness Handi-cap Inventory (DHI) questionnaire was translated and validated. The methodology of posturography with head movements with a frequency of 0.3 Hz was also developed in the group with chronic vestibular disorders. Simultaneous measurements were performed (static posturogrphy vs. MEDIPOST) in the CTSIB-M (Modified Clinical Test of Sensory Interaction in Balance) test in healthy subjects and patients with unilateral peripheral dysfunction.&lt;/br&gt; &lt;/br&gt; &lt;b&gt;Results:&lt;/b&gt; In the posturography with head movements the improvement of sensitivity (67 to 74%) and specificity (65 to 71%) was noted. In the CTSIB-M test the intraclass correlation coefficients for both methods were 0.9. The greatest differences between examinations were observed for the mean angular velocity in the tests on the foam (trials no. 3 and 4), in particular on the foam with eyes closed (trial no. 4 - sensitivity 86.4%, specificity 87.7%). Two functional tests were analyzed: the Swap Seats test and the 360 degree turn test. In the former, the results are studied from 6 sensors - 86% of the true positives and 73% of the true negatives for the fall/ no-fall group classification. The second test differentiates people with vestibular impairment and healthy people. It can be analyzed with 1 (sensitivity 80%) and 6 sensors (sensitivity 86%, specificity 84%). Currently, the MEDIPOST device is in the development and certification phase.</p>","PeriodicalId":42608,"journal":{"name":"Polish Journal of Otolaryngology","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2022-03-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Innovative System for Evaluation and Rehabilitation of Human Imbalance.\",\"authors\":\"Anna Gawrońska,&nbsp;Ewa Zamysłowska-Szmytke,&nbsp;Magdalena Janc,&nbsp;Rafal Kotas,&nbsp;Marek Kamiński,&nbsp;Paweł Marciniak,&nbsp;Wojciech Tylman,&nbsp;Sebastian Woźniak,&nbsp;Jan Napieralski,&nbsp;Bartosz Sakowicz,&nbsp;Anna Pajor,&nbsp;Oskar Rosiak,&nbsp;Anna Puzio,&nbsp;Weronika Lucas-Brot,&nbsp;Magdalena Józefowicz-Korczyńska\",\"doi\":\"10.5604/01.3001.0015.7927\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>&lt;b&gt;Introduction:&lt;/b&gt; Mobile posturography is based on wearable inertial sensors; it allows to test static stability (static posturography) and gait disturbances. &lt;/br&gt; &lt;/br&gt; &lt;b&gt;Aim:&lt;/b&gt; The aim of this work was to present the results of research on the innovative MEDIPOST system used for diagnosis and rehabilitation of balance disorders. &lt;/br&gt; &lt;/br&gt; &lt;b&gt;Material and methods:&lt;/b&gt; Fourteen articles published in influenced foreign journals were presented and discussed. The deve-lopment and construction of the device was preceded by a literature review and methodological work. The Dizziness Handi-cap Inventory (DHI) questionnaire was translated and validated. The methodology of posturography with head movements with a frequency of 0.3 Hz was also developed in the group with chronic vestibular disorders. Simultaneous measurements were performed (static posturogrphy vs. MEDIPOST) in the CTSIB-M (Modified Clinical Test of Sensory Interaction in Balance) test in healthy subjects and patients with unilateral peripheral dysfunction.&lt;/br&gt; &lt;/br&gt; &lt;b&gt;Results:&lt;/b&gt; In the posturography with head movements the improvement of sensitivity (67 to 74%) and specificity (65 to 71%) was noted. In the CTSIB-M test the intraclass correlation coefficients for both methods were 0.9. The greatest differences between examinations were observed for the mean angular velocity in the tests on the foam (trials no. 3 and 4), in particular on the foam with eyes closed (trial no. 4 - sensitivity 86.4%, specificity 87.7%). Two functional tests were analyzed: the Swap Seats test and the 360 degree turn test. In the former, the results are studied from 6 sensors - 86% of the true positives and 73% of the true negatives for the fall/ no-fall group classification. The second test differentiates people with vestibular impairment and healthy people. It can be analyzed with 1 (sensitivity 80%) and 6 sensors (sensitivity 86%, specificity 84%). Currently, the MEDIPOST device is in the development and certification phase.</p>\",\"PeriodicalId\":42608,\"journal\":{\"name\":\"Polish Journal of Otolaryngology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2022-03-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Polish Journal of Otolaryngology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5604/01.3001.0015.7927\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OTORHINOLARYNGOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish Journal of Otolaryngology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5604/01.3001.0015.7927","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 1

摘要

& lt; b>介绍:& lt; / b>移动姿势测量基于可穿戴惯性传感器;它允许测试静态稳定性(静态姿势)和步态干扰。& lt; / br>& lt; / br>& lt; b>目的:& lt; / b>这项工作的目的是介绍用于平衡障碍诊断和康复的创新MEDIPOST系统的研究结果。& lt; / br>& lt; / br>材料和方法:</b>在国外有影响的期刊上发表了14篇论文。该装置的开发和构建之前进行了文献综述和方法学工作。翻译并验证眩晕残障量表(DHI)。在慢性前庭疾病组中也发展了以0.3 Hz频率进行头部运动的姿势照相方法。在健康受试者和单侧外周功能障碍患者的ctsibb - m(平衡感觉相互作用改良临床试验)测试中同时进行测量(静态姿势摄影与MEDIPOST)。& lt; / br>& lt; b>结果:& lt; / b>在有头部运动的姿势照相中,灵敏度(67 ~ 74%)和特异性(65 ~ 71%)得到了改善。在ctsibb - m检验中,两种方法的类内相关系数均为0.9。两次试验之间的最大差异是泡沫试验的平均角速度(试验号:1)。3和4),特别是在闭着眼睛的泡沫上(试验号:敏感性86.4%,特异性87.7%)。分析了两项功能测试:互换座椅测试和360度转弯测试。在前者中,对6个传感器的结果进行了研究——86%的真阳性和73%的真阴性用于跌倒/不跌倒组分类。第二个测试可以区分前庭功能障碍患者和健康人。可采用1个(灵敏度80%)和6个传感器(灵敏度86%,特异性84%)进行分析。目前,MEDIPOST设备正处于开发和认证阶段。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Innovative System for Evaluation and Rehabilitation of Human Imbalance.

<b>Introduction:</b> Mobile posturography is based on wearable inertial sensors; it allows to test static stability (static posturography) and gait disturbances. </br> </br> <b>Aim:</b> The aim of this work was to present the results of research on the innovative MEDIPOST system used for diagnosis and rehabilitation of balance disorders. </br> </br> <b>Material and methods:</b> Fourteen articles published in influenced foreign journals were presented and discussed. The deve-lopment and construction of the device was preceded by a literature review and methodological work. The Dizziness Handi-cap Inventory (DHI) questionnaire was translated and validated. The methodology of posturography with head movements with a frequency of 0.3 Hz was also developed in the group with chronic vestibular disorders. Simultaneous measurements were performed (static posturogrphy vs. MEDIPOST) in the CTSIB-M (Modified Clinical Test of Sensory Interaction in Balance) test in healthy subjects and patients with unilateral peripheral dysfunction.</br> </br> <b>Results:</b> In the posturography with head movements the improvement of sensitivity (67 to 74%) and specificity (65 to 71%) was noted. In the CTSIB-M test the intraclass correlation coefficients for both methods were 0.9. The greatest differences between examinations were observed for the mean angular velocity in the tests on the foam (trials no. 3 and 4), in particular on the foam with eyes closed (trial no. 4 - sensitivity 86.4%, specificity 87.7%). Two functional tests were analyzed: the Swap Seats test and the 360 degree turn test. In the former, the results are studied from 6 sensors - 86% of the true positives and 73% of the true negatives for the fall/ no-fall group classification. The second test differentiates people with vestibular impairment and healthy people. It can be analyzed with 1 (sensitivity 80%) and 6 sensors (sensitivity 86%, specificity 84%). Currently, the MEDIPOST device is in the development and certification phase.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Polish Journal of Otolaryngology
Polish Journal of Otolaryngology OTORHINOLARYNGOLOGY-
CiteScore
1.30
自引率
16.70%
发文量
15
期刊最新文献
Memory Load Test - A Concept for Cognitive Reserve Evaluation with Auditory Perception. Contemporary directions in the therapy of sensory hearing loss. Polish cross-cultural adaptation of the Glasgow Benefit Inventory as an instrument for the post-intervention measurement of change after Gamma Knife treatment. Soft tissue sarcomas of the head and neck region: clinical and histopathological study of 39 patients. Polish Translation and Validation of the SCHNOS (Standardized Cosmesis and Health Nasal Outcomes Survey) Questionnaire.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1