{"title":"薄支气管镜下桡骨支气管内超声引导下经支气管肺活检距离测量与导管鞘活检诊断直径≥3cm肺周围病变的比较","authors":"Shuhong Guan, Jun Zhou, Qiudi Zhang, Qianqian Xu, Xiong Xu, Sujuan Zhang","doi":"10.4103/atm.atm_495_21","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study aims to explore the diagnostic values of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance (rEBUS-D-TBLB) measurement and with guide sheath (rEBUS-GS-TBLB) for peripheral pulmonary lesions (PPLs) with a diameter ≥3 cm by thin bronchoscope.</p><p><strong>Patients and methods: </strong>Six hundred and three patients with PPL (diameter ≥3 cm) were enrolled in this study. The subjects were divided into the rEBUS-D-TBLB and rEBUS-GS-TBLB groups by the random number table method. Patients were assigned to undergo rEBUS-D-TBLB or rEBUS-GS-TBLB, respectively. The histopathology, positive diagnosis rates, duration of the procedure, and postoperative adverse effects between the two groups were examined.</p><p><strong>Results: </strong>A total of 569 patients were included in this study according to the inclusion and exclusion criteria, with 282 cases in the rEBUS-D-TBLB group and 287 cases in the rEBUS-GS-TBLB group. For malignant diseases, the positive diagnosis rates of PPL in the outer/inner-middle lung bands and the right-upper/-lower lung lobes by rEBUS-D-TBLB were noninferior to those of rEBUS-GS-TBLB. The duration of the procedure of rEBUS-D-TBLB was longer than that of rEBUS-GS-TBLB. There were 14 cases of hemorrhage >50 mL, 1 case of postoperative chest pain in the rEBUS-D-TBLB group, and 3 cases of hemorrhage >50 mL in the rEBUS-GS-TBLB group.</p><p><strong>Conclusion: </strong>REBUS-D-TBLB by thin bronchoscope has a high diagnostic value for PPL with a diameter ≥3 cm, which may be considered a useful alternative for rEBUS-GS-TBLB in the clinic.</p>","PeriodicalId":50760,"journal":{"name":"Annals of Thoracic Medicine","volume":"17 3","pages":"151-158"},"PeriodicalIF":2.1000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/c7/ee/ATM-17-151.PMC9374119.pdf","citationCount":"0","resultStr":"{\"title\":\"Comparison of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance measurement versus with guide sheath in diagnosing peripheral pulmonary lesions with a diameter ≥3 cm by thin bronchoscope.\",\"authors\":\"Shuhong Guan, Jun Zhou, Qiudi Zhang, Qianqian Xu, Xiong Xu, Sujuan Zhang\",\"doi\":\"10.4103/atm.atm_495_21\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>This study aims to explore the diagnostic values of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance (rEBUS-D-TBLB) measurement and with guide sheath (rEBUS-GS-TBLB) for peripheral pulmonary lesions (PPLs) with a diameter ≥3 cm by thin bronchoscope.</p><p><strong>Patients and methods: </strong>Six hundred and three patients with PPL (diameter ≥3 cm) were enrolled in this study. The subjects were divided into the rEBUS-D-TBLB and rEBUS-GS-TBLB groups by the random number table method. Patients were assigned to undergo rEBUS-D-TBLB or rEBUS-GS-TBLB, respectively. The histopathology, positive diagnosis rates, duration of the procedure, and postoperative adverse effects between the two groups were examined.</p><p><strong>Results: </strong>A total of 569 patients were included in this study according to the inclusion and exclusion criteria, with 282 cases in the rEBUS-D-TBLB group and 287 cases in the rEBUS-GS-TBLB group. For malignant diseases, the positive diagnosis rates of PPL in the outer/inner-middle lung bands and the right-upper/-lower lung lobes by rEBUS-D-TBLB were noninferior to those of rEBUS-GS-TBLB. The duration of the procedure of rEBUS-D-TBLB was longer than that of rEBUS-GS-TBLB. There were 14 cases of hemorrhage >50 mL, 1 case of postoperative chest pain in the rEBUS-D-TBLB group, and 3 cases of hemorrhage >50 mL in the rEBUS-GS-TBLB group.</p><p><strong>Conclusion: </strong>REBUS-D-TBLB by thin bronchoscope has a high diagnostic value for PPL with a diameter ≥3 cm, which may be considered a useful alternative for rEBUS-GS-TBLB in the clinic.</p>\",\"PeriodicalId\":50760,\"journal\":{\"name\":\"Annals of Thoracic Medicine\",\"volume\":\"17 3\",\"pages\":\"151-158\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2022-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/c7/ee/ATM-17-151.PMC9374119.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Thoracic Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4103/atm.atm_495_21\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/7/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Thoracic Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/atm.atm_495_21","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/7/9 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
摘要
目的:探讨薄支气管镜下桡骨支气管内超声引导下经支气管肺活检术(rEBUS-D-TBLB)与导管鞘(rEBUS-GS-TBLB)对直径≥3cm的肺周围病变(pps)的诊断价值。患者和方法:本研究纳入了603例PPL(直径≥3cm)患者。采用随机数字表法将受试者分为rEBUS-D-TBLB组和rEBUS-GS-TBLB组。患者分别接受rEBUS-D-TBLB或rEBUS-GS-TBLB治疗。观察两组患者的组织病理学、阳性诊断率、手术时间及术后不良反应。结果:按照纳入和排除标准共纳入569例患者,其中rEBUS-D-TBLB组282例,rEBUS-GS-TBLB组287例。对于恶性疾病,rEBUS-D-TBLB对肺外、内、中带及右上、下肺叶PPL的阳性率不低于rEBUS-GS-TBLB。rEBUS-D-TBLB的处理时间比rEBUS-GS-TBLB的处理时间长。rEBUS-D-TBLB组出血>50 mL 14例,术后胸痛1例,rEBUS-GS-TBLB组出血>50 mL 3例。结论:薄支气管镜下REBUS-D-TBLB对直径≥3cm的PPL有较高的诊断价值,可作为临床替代rEBUS-GS-TBLB的有效方法。
Comparison of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance measurement versus with guide sheath in diagnosing peripheral pulmonary lesions with a diameter ≥3 cm by thin bronchoscope.
Objective: This study aims to explore the diagnostic values of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance (rEBUS-D-TBLB) measurement and with guide sheath (rEBUS-GS-TBLB) for peripheral pulmonary lesions (PPLs) with a diameter ≥3 cm by thin bronchoscope.
Patients and methods: Six hundred and three patients with PPL (diameter ≥3 cm) were enrolled in this study. The subjects were divided into the rEBUS-D-TBLB and rEBUS-GS-TBLB groups by the random number table method. Patients were assigned to undergo rEBUS-D-TBLB or rEBUS-GS-TBLB, respectively. The histopathology, positive diagnosis rates, duration of the procedure, and postoperative adverse effects between the two groups were examined.
Results: A total of 569 patients were included in this study according to the inclusion and exclusion criteria, with 282 cases in the rEBUS-D-TBLB group and 287 cases in the rEBUS-GS-TBLB group. For malignant diseases, the positive diagnosis rates of PPL in the outer/inner-middle lung bands and the right-upper/-lower lung lobes by rEBUS-D-TBLB were noninferior to those of rEBUS-GS-TBLB. The duration of the procedure of rEBUS-D-TBLB was longer than that of rEBUS-GS-TBLB. There were 14 cases of hemorrhage >50 mL, 1 case of postoperative chest pain in the rEBUS-D-TBLB group, and 3 cases of hemorrhage >50 mL in the rEBUS-GS-TBLB group.
Conclusion: REBUS-D-TBLB by thin bronchoscope has a high diagnostic value for PPL with a diameter ≥3 cm, which may be considered a useful alternative for rEBUS-GS-TBLB in the clinic.
期刊介绍:
The journal will cover studies related to multidisciplinary specialties of chest medicine, such as adult and pediatrics pulmonology, thoracic surgery, critical care medicine, respiratory care, transplantation, sleep medicine, related basic medical sciences, and more. The journal also features basic science, special reports, case reports, board review , and more. Editorials and communications to the editor that explore controversial issues and encourage further discussion by physicians dealing with chest medicine.