Qvar和Turbuhaler吸入器在三种口腔咽喉模型中沉积的体内外比较。

Yu Zhang, Kyle Gilbertson, Warren H Finlay
{"title":"Qvar和Turbuhaler吸入器在三种口腔咽喉模型中沉积的体内外比较。","authors":"Yu Zhang,&nbsp;Kyle Gilbertson,&nbsp;Warren H Finlay","doi":"10.1089/jam.2007.0584","DOIUrl":null,"url":null,"abstract":"<p><p>In vitro polydisperse aerosol deposition in three mouth-throat models, namely, the USP (United States Pharmacopeia) mouth-throat (induction port), idealized mouth-throat, and highly idealized mouth-throat, was investigated experimentally. Aerosol particles emitted from two commercial inhalers, Qvar (pMDI) and Turbuhaler (DPI), were used. The in vitro deposition results in these three mouth-throat models were compared with in vivo data available from the literature. For the DPI, mouth-throat deposition was 57.3 +/- 4.5% for the USP mouth-throat, 67.8 +/- 2.2% for the idealized mouth-throat, and 69.3 +/- 1.1% for the highly idealized mouth-throat, which are all relatively close to the in vivo value of 65.8 +/- 10.1%. In contrast, for the pMDI, aerosol deposition in the idealized mouth-throat (25.8 +/- 4.2%) and the highly idealized mouth-throat (24.9 +/- 2.8%) agrees with the in vivo data (29.0 +/- 18.0%) reported in the literature better than that for the USP mouth-throat (12.2 +/- 2.7%). In both cases, the USP mouth-throat gives the lowest deposition among the three mouth-throat models studied. In summary, both the idealized mouth-throat and highly idealized mouth-throat improve the accuracy of predicted mean in vivo deposition in the mouth-throat region. This result hints at the potential applicability of either the idealized mouth-throat or highly idealized mouth-throat as a future USP mouth-throat standard to provide mean value prediction of in vivo mouth-throat deposition.</p>","PeriodicalId":14878,"journal":{"name":"Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine","volume":"20 3","pages":"227-35"},"PeriodicalIF":0.0000,"publicationDate":"2007-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1089/jam.2007.0584","citationCount":"110","resultStr":"{\"title\":\"In vivo-in vitro comparison of deposition in three mouth-throat models with Qvar and Turbuhaler inhalers.\",\"authors\":\"Yu Zhang,&nbsp;Kyle Gilbertson,&nbsp;Warren H Finlay\",\"doi\":\"10.1089/jam.2007.0584\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In vitro polydisperse aerosol deposition in three mouth-throat models, namely, the USP (United States Pharmacopeia) mouth-throat (induction port), idealized mouth-throat, and highly idealized mouth-throat, was investigated experimentally. Aerosol particles emitted from two commercial inhalers, Qvar (pMDI) and Turbuhaler (DPI), were used. The in vitro deposition results in these three mouth-throat models were compared with in vivo data available from the literature. For the DPI, mouth-throat deposition was 57.3 +/- 4.5% for the USP mouth-throat, 67.8 +/- 2.2% for the idealized mouth-throat, and 69.3 +/- 1.1% for the highly idealized mouth-throat, which are all relatively close to the in vivo value of 65.8 +/- 10.1%. In contrast, for the pMDI, aerosol deposition in the idealized mouth-throat (25.8 +/- 4.2%) and the highly idealized mouth-throat (24.9 +/- 2.8%) agrees with the in vivo data (29.0 +/- 18.0%) reported in the literature better than that for the USP mouth-throat (12.2 +/- 2.7%). In both cases, the USP mouth-throat gives the lowest deposition among the three mouth-throat models studied. In summary, both the idealized mouth-throat and highly idealized mouth-throat improve the accuracy of predicted mean in vivo deposition in the mouth-throat region. This result hints at the potential applicability of either the idealized mouth-throat or highly idealized mouth-throat as a future USP mouth-throat standard to provide mean value prediction of in vivo mouth-throat deposition.</p>\",\"PeriodicalId\":14878,\"journal\":{\"name\":\"Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine\",\"volume\":\"20 3\",\"pages\":\"227-35\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1089/jam.2007.0584\",\"citationCount\":\"110\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1089/jam.2007.0584\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1089/jam.2007.0584","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 110

摘要

在USP(美国药典)口喉(诱导口)、理想口喉和高度理想口喉三种口喉模型中,对体外多分散气溶胶沉积进行了实验研究。使用了两个商用吸入器Qvar (pMDI)和Turbuhaler (DPI)排放的气溶胶颗粒。将这三种口腔-喉咙模型的体外沉积结果与文献中提供的体内数据进行比较。对于DPI, USP口腔-喉部沉积为57.3 +/- 4.5%,理想口腔-喉部沉积为67.8 +/- 2.2%,高度理想口腔-喉部沉积为69.3 +/- 1.1%,与体内值65.8 +/- 10.1%较为接近。相比之下,对于pMDI,理想口喉(25.8 +/- 4.2%)和高度理想口喉(24.9 +/- 2.8%)的气溶胶沉积与文献报道的体内数据(29.0 +/- 18.0%)的一致性优于USP口喉(12.2 +/- 2.7%)。在这两种情况下,USP口喉在三种研究的口喉模型中给出了最低的沉积。总之,理想口腔-喉咙和高度理想口腔-喉咙都提高了预测口腔-喉咙区域平均体内沉积的准确性。该结果提示了理想口腔-喉咙或高度理想口腔-喉咙作为未来USP口腔-喉咙标准的潜在适用性,以提供体内口腔-喉咙沉积的平均值预测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
In vivo-in vitro comparison of deposition in three mouth-throat models with Qvar and Turbuhaler inhalers.

In vitro polydisperse aerosol deposition in three mouth-throat models, namely, the USP (United States Pharmacopeia) mouth-throat (induction port), idealized mouth-throat, and highly idealized mouth-throat, was investigated experimentally. Aerosol particles emitted from two commercial inhalers, Qvar (pMDI) and Turbuhaler (DPI), were used. The in vitro deposition results in these three mouth-throat models were compared with in vivo data available from the literature. For the DPI, mouth-throat deposition was 57.3 +/- 4.5% for the USP mouth-throat, 67.8 +/- 2.2% for the idealized mouth-throat, and 69.3 +/- 1.1% for the highly idealized mouth-throat, which are all relatively close to the in vivo value of 65.8 +/- 10.1%. In contrast, for the pMDI, aerosol deposition in the idealized mouth-throat (25.8 +/- 4.2%) and the highly idealized mouth-throat (24.9 +/- 2.8%) agrees with the in vivo data (29.0 +/- 18.0%) reported in the literature better than that for the USP mouth-throat (12.2 +/- 2.7%). In both cases, the USP mouth-throat gives the lowest deposition among the three mouth-throat models studied. In summary, both the idealized mouth-throat and highly idealized mouth-throat improve the accuracy of predicted mean in vivo deposition in the mouth-throat region. This result hints at the potential applicability of either the idealized mouth-throat or highly idealized mouth-throat as a future USP mouth-throat standard to provide mean value prediction of in vivo mouth-throat deposition.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Formoterol turbuhaler is as effective as salbutamol diskus in relieving adenosine-induced bronchoconstriction in children. An in vitro study to assess facial and ocular deposition from Respimat Soft Mist inhaler. Exhaled breath condensate pH is increased after moderate exercise. The analysis and prediction of functional robustness of inhaler devices. Comparison of the Diskus inhaler and the Handihaler regarding preference and ease of use.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1