{"title":"对固定正畸治疗的有效性和效率的评估——比较标准和计算机辅助设计和制造使用间接粘接的传统托槽系统:一项回顾性研究。","authors":"Mario Palone ,&nbsp;Chiara Bizzocchi ,&nbsp;Daniela Guiducci ,&nbsp;Francesca Cremonini ,&nbsp;Federica Pellitteri ,&nbsp;Giorgio Alfredo Spedicato ,&nbsp;Alessandro Verducci ,&nbsp;Luca Lombardo","doi":"10.1016/j.ejwf.2023.08.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>To compare the effectiveness and efficiency of orthodontic treatment (OT) with standard versus computer-aided design and computer-aided manufacturing (CAD/CAM) indirect bonding of conventional brackets.</p></div><div><h3>Methods</h3><p>This retrospective study examined two groups: standard indirect bonding group (12 males, 13 females; mean age 12.21 ± 0.52 years), and digital indirect bonding group (11 males, 14 females; mean age 12.76 ± 1.32 years), treated via a CAD/CAM indirect bonding system. Conventional brackets were used in both groups. Pretreatment and post-treatment records were acquired for all subjects. Weighted Peer Assessment Rating (W-PAR) index was used to assess the effectiveness of OT, in conjunction with five angular cephalometric measurements (ANB°, Sn-GoGn°, U1-PP°, IMPA° and FMA°) and comparatively analyzed using generalized mixed-effects models and post hoc test. Treatment efficiency was assessed in terms of the numbers of bracket repositionings, archwire bends, accidental bracket debondings, appointments and treatment months. Comparative analysis of efficiency was performed using the asymptotic Wilcoxon–Mann–Witney test. Statistical significance was set at 5%.</p></div><div><h3>Results</h3><p>Total W-PAR and W-PAR component scores decreased significantly during treatment for both groups and in a similar way. Cephalometric measures ANB° and IMPA° significantly decreased and increased, respectively. Significantly fewer bracket repositionings, number of appointments and treatment months were recorded in group digital indirect bonding.</p></div><div><h3>Conclusions</h3><p>Although both methods investigated were effective to achieve good outcomes, CAD/CAM indirect bonding method increased the efficiency of OT, when conventional brackets are used.</p></div>","PeriodicalId":43456,"journal":{"name":"Journal of the World Federation of Orthodontists","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of effectiveness and efficiency of fixed orthodontic treatment comparing standard and computer-aided design and manufacturing conventional bracket systems using indirect bonding for both: A retrospective study\",\"authors\":\"Mario Palone ,&nbsp;Chiara Bizzocchi ,&nbsp;Daniela Guiducci ,&nbsp;Francesca Cremonini ,&nbsp;Federica Pellitteri ,&nbsp;Giorgio Alfredo Spedicato ,&nbsp;Alessandro Verducci ,&nbsp;Luca Lombardo\",\"doi\":\"10.1016/j.ejwf.2023.08.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>To compare the effectiveness and efficiency of orthodontic treatment (OT) with standard versus computer-aided design and computer-aided manufacturing (CAD/CAM) indirect bonding of conventional brackets.</p></div><div><h3>Methods</h3><p>This retrospective study examined two groups: standard indirect bonding group (12 males, 13 females; mean age 12.21 ± 0.52 years), and digital indirect bonding group (11 males, 14 females; mean age 12.76 ± 1.32 years), treated via a CAD/CAM indirect bonding system. Conventional brackets were used in both groups. Pretreatment and post-treatment records were acquired for all subjects. Weighted Peer Assessment Rating (W-PAR) index was used to assess the effectiveness of OT, in conjunction with five angular cephalometric measurements (ANB°, Sn-GoGn°, U1-PP°, IMPA° and FMA°) and comparatively analyzed using generalized mixed-effects models and post hoc test. Treatment efficiency was assessed in terms of the numbers of bracket repositionings, archwire bends, accidental bracket debondings, appointments and treatment months. Comparative analysis of efficiency was performed using the asymptotic Wilcoxon–Mann–Witney test. Statistical significance was set at 5%.</p></div><div><h3>Results</h3><p>Total W-PAR and W-PAR component scores decreased significantly during treatment for both groups and in a similar way. Cephalometric measures ANB° and IMPA° significantly decreased and increased, respectively. Significantly fewer bracket repositionings, number of appointments and treatment months were recorded in group digital indirect bonding.</p></div><div><h3>Conclusions</h3><p>Although both methods investigated were effective to achieve good outcomes, CAD/CAM indirect bonding method increased the efficiency of OT, when conventional brackets are used.</p></div>\",\"PeriodicalId\":43456,\"journal\":{\"name\":\"Journal of the World Federation of Orthodontists\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the World Federation of Orthodontists\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2212443823000668\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the World Federation of Orthodontists","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2212443823000668","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景:比较标准正畸治疗(OT)与传统托槽的计算机辅助设计和计算机辅助制造(CAD/CAM)间接结合的有效性和效率。方法:本回顾性研究检查了两组:标准间接结合组(12名男性,13名女性;平均年龄12.21±0.52岁)和数字间接结合组,通过CAD/CAM间接结合系统进行治疗。两组均使用传统括号。获取所有受试者的治疗前和治疗后记录。加权同行评估评分(W-PAR)指数用于评估OT的有效性,结合五种头部角度测量(ANB°、Sn-GoGn°、U1-PP°、IMPA°和FMA°),并使用广义混合效应模型和事后检验进行比较分析。根据托槽复位次数、弓丝弯曲次数、意外托槽脱落次数、预约次数和治疗月数来评估治疗效率。使用渐近Wilcoxon-Mann-Witney检验对效率进行比较分析。统计显著性设定为5%。结果:治疗期间,两组患者的总W-PAR和W-PAR成分得分均显著下降,且下降方式相似。头部测量ANB°和IMPA°分别显著降低和增加。在数字间接结合组中,支架复位、预约次数和治疗月数显著减少。结论:尽管所研究的两种方法都能取得良好的效果,但当使用传统托槽时,CAD/CAM间接结合方法提高了OT的效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of effectiveness and efficiency of fixed orthodontic treatment comparing standard and computer-aided design and manufacturing conventional bracket systems using indirect bonding for both: A retrospective study

Background

To compare the effectiveness and efficiency of orthodontic treatment (OT) with standard versus computer-aided design and computer-aided manufacturing (CAD/CAM) indirect bonding of conventional brackets.

Methods

This retrospective study examined two groups: standard indirect bonding group (12 males, 13 females; mean age 12.21 ± 0.52 years), and digital indirect bonding group (11 males, 14 females; mean age 12.76 ± 1.32 years), treated via a CAD/CAM indirect bonding system. Conventional brackets were used in both groups. Pretreatment and post-treatment records were acquired for all subjects. Weighted Peer Assessment Rating (W-PAR) index was used to assess the effectiveness of OT, in conjunction with five angular cephalometric measurements (ANB°, Sn-GoGn°, U1-PP°, IMPA° and FMA°) and comparatively analyzed using generalized mixed-effects models and post hoc test. Treatment efficiency was assessed in terms of the numbers of bracket repositionings, archwire bends, accidental bracket debondings, appointments and treatment months. Comparative analysis of efficiency was performed using the asymptotic Wilcoxon–Mann–Witney test. Statistical significance was set at 5%.

Results

Total W-PAR and W-PAR component scores decreased significantly during treatment for both groups and in a similar way. Cephalometric measures ANB° and IMPA° significantly decreased and increased, respectively. Significantly fewer bracket repositionings, number of appointments and treatment months were recorded in group digital indirect bonding.

Conclusions

Although both methods investigated were effective to achieve good outcomes, CAD/CAM indirect bonding method increased the efficiency of OT, when conventional brackets are used.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of the World Federation of Orthodontists
Journal of the World Federation of Orthodontists DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.80
自引率
4.80%
发文量
34
期刊最新文献
Nonsurgical treatment of an adult patient with severe transversal skeletal discrepancy: Tooth bone-borne tandem expander and hybrid aligner approach Comparison of the accuracy of bracket axial positioning with and without radiographic support and according to practitioner experience: A three-dimensional study Evaluation of incipient enamel-carious-like lesion treated with hydroxyapatite-chitosan nanocomposite hydrogel. Evaluation of incipient enamel-carious–like lesion treated with hydroxyapatite-chitosan nanocomposite hydrogel Validity of digital analysis versus manual analysis on orthodontic casts
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1