椎间盘超载对伤害感受器钙闪烁的影响。

IF 3.4 3区 医学 Q1 ORTHOPEDICS JOR Spine Pub Date : 2023-06-09 DOI:10.1002/jsp2.1267
Jan Gewiess, Janick Eglauf, Astrid Soubrier, Sibylle Grad, Mauro Alini, Marianna Peroglio, Junxuan Ma
{"title":"椎间盘超载对伤害感受器钙闪烁的影响。","authors":"Jan Gewiess,&nbsp;Janick Eglauf,&nbsp;Astrid Soubrier,&nbsp;Sibylle Grad,&nbsp;Mauro Alini,&nbsp;Marianna Peroglio,&nbsp;Junxuan Ma","doi":"10.1002/jsp2.1267","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Introduction</h3>\n \n <p>Mechanical overloading can trigger a degenerative-like cascade in an organ culture of intervertebral disc (IVD). Whether the overloaded IVD can influence the activation of nociceptors (i.e., the damage sensing neurons) remains unknown. The study aims to investigate the influence of overloaded IVD conditioned medium (CM) on the activation of nociceptors.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>In the static loading regime, force-controlled loading of 0.2 MPa for 20 h/day representing “long-term sitting and standing” was compared with a displacement-controlled loading maintaining original IVD height. In the dynamic loading regime, high-frequency-intensity loading representing degenerative “wear and tear” was compared with a lower-frequency-intensity loading. CM of differently loaded IVDs were collected to stimulate the primary bovine dorsal root ganglion (DRG) cultures. Calcium imaging (Fluo-4) and calcitonin gene-related peptide (CGRP) immunofluorescent labeling were jointly used to record the calcium flickering in CGRP(+) nociceptors.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Force-controlled loading led to a higher IVD cell death compared to displacement-controlled loading. Both static and dynamic overloading (force-controlled and high-frequency-intensity loadings) elevated the frequency of calcium flickering in the subsurface space of CGRP(+) nociceptors compared to their mild loading counterparts.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>In the organ culture system, IVD overloading mediated an altered IVD-nociceptor communication suggesting a biological mechanism associated with discogenic pain.</p>\n </section>\n </div>","PeriodicalId":14876,"journal":{"name":"JOR Spine","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2023-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/ee/13/JSP2-6-e1267.PMC10540821.pdf","citationCount":"1","resultStr":"{\"title\":\"The influence of intervertebral disc overloading on nociceptor calcium flickering\",\"authors\":\"Jan Gewiess,&nbsp;Janick Eglauf,&nbsp;Astrid Soubrier,&nbsp;Sibylle Grad,&nbsp;Mauro Alini,&nbsp;Marianna Peroglio,&nbsp;Junxuan Ma\",\"doi\":\"10.1002/jsp2.1267\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Introduction</h3>\\n \\n <p>Mechanical overloading can trigger a degenerative-like cascade in an organ culture of intervertebral disc (IVD). Whether the overloaded IVD can influence the activation of nociceptors (i.e., the damage sensing neurons) remains unknown. The study aims to investigate the influence of overloaded IVD conditioned medium (CM) on the activation of nociceptors.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>In the static loading regime, force-controlled loading of 0.2 MPa for 20 h/day representing “long-term sitting and standing” was compared with a displacement-controlled loading maintaining original IVD height. In the dynamic loading regime, high-frequency-intensity loading representing degenerative “wear and tear” was compared with a lower-frequency-intensity loading. CM of differently loaded IVDs were collected to stimulate the primary bovine dorsal root ganglion (DRG) cultures. Calcium imaging (Fluo-4) and calcitonin gene-related peptide (CGRP) immunofluorescent labeling were jointly used to record the calcium flickering in CGRP(+) nociceptors.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Force-controlled loading led to a higher IVD cell death compared to displacement-controlled loading. Both static and dynamic overloading (force-controlled and high-frequency-intensity loadings) elevated the frequency of calcium flickering in the subsurface space of CGRP(+) nociceptors compared to their mild loading counterparts.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>In the organ culture system, IVD overloading mediated an altered IVD-nociceptor communication suggesting a biological mechanism associated with discogenic pain.</p>\\n </section>\\n </div>\",\"PeriodicalId\":14876,\"journal\":{\"name\":\"JOR Spine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2023-06-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/ee/13/JSP2-6-e1267.PMC10540821.pdf\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JOR Spine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/jsp2.1267\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JOR Spine","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jsp2.1267","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 1

摘要

引言:机械过载可在椎间盘(IVD)的器官培养中引发退行性样级联反应。超负荷IVD是否会影响伤害感受器(即损伤感知神经元)的激活仍然未知。本研究旨在探讨超负荷体外受精条件培养基(CM)对伤害感受器激活的影响。方法:在静态加载状态下,力控制加载0.2 20 MPa 将代表“长期坐着和站着”的h/天与保持原始IVD高度的位移控制负荷进行比较。在动态载荷状态下,将代表退化“磨损”的高频强度载荷与低频强度载荷进行比较。收集不同负载IVD的CM以刺激原代牛背根神经节(DRG)培养物。钙显像(Fluo-4)和降钙素基因相关肽(CGRP)免疫荧光标记联合用于记录CGRP(+)伤害感受器中的钙闪烁。结果:与位移控制加载相比,力控制加载导致更高的IVD细胞死亡。与轻度负荷对应物相比,静态和动态过载(力控制和高频强度负荷)都提高了CGRP(+)伤害感受器地下空间中钙闪烁的频率。结论:在器官培养系统中,IVD过载介导了IVD伤害感受器通讯的改变,这表明了与椎间盘源性疼痛相关的生物学机制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The influence of intervertebral disc overloading on nociceptor calcium flickering

Introduction

Mechanical overloading can trigger a degenerative-like cascade in an organ culture of intervertebral disc (IVD). Whether the overloaded IVD can influence the activation of nociceptors (i.e., the damage sensing neurons) remains unknown. The study aims to investigate the influence of overloaded IVD conditioned medium (CM) on the activation of nociceptors.

Methods

In the static loading regime, force-controlled loading of 0.2 MPa for 20 h/day representing “long-term sitting and standing” was compared with a displacement-controlled loading maintaining original IVD height. In the dynamic loading regime, high-frequency-intensity loading representing degenerative “wear and tear” was compared with a lower-frequency-intensity loading. CM of differently loaded IVDs were collected to stimulate the primary bovine dorsal root ganglion (DRG) cultures. Calcium imaging (Fluo-4) and calcitonin gene-related peptide (CGRP) immunofluorescent labeling were jointly used to record the calcium flickering in CGRP(+) nociceptors.

Results

Force-controlled loading led to a higher IVD cell death compared to displacement-controlled loading. Both static and dynamic overloading (force-controlled and high-frequency-intensity loadings) elevated the frequency of calcium flickering in the subsurface space of CGRP(+) nociceptors compared to their mild loading counterparts.

Conclusion

In the organ culture system, IVD overloading mediated an altered IVD-nociceptor communication suggesting a biological mechanism associated with discogenic pain.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
JOR Spine
JOR Spine ORTHOPEDICS-
CiteScore
6.40
自引率
18.90%
发文量
42
审稿时长
10 weeks
期刊最新文献
Deep learning-based structure segmentation and intramuscular fat annotation on lumbar magnetic resonance imaging Development and validation of deep learning models for identifying the brand of pedicle screws on plain spine radiographs Neural network segmentation of disc volume from magnetic resonance images and the effect of degeneration and spinal level Protective effects of curcumin against spinal cord injury Clinical implications of linking microstructure, spatial biochemical, spatial biomechanical, and radiological features in ligamentum flavum degeneration
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1