{"title":"触觉机器人引导下的无瓣牙种植体手术:一例报告。","authors":"Mohamed Ali DDS","doi":"10.1111/cid.13279","DOIUrl":null,"url":null,"abstract":"<p>This case report presents the use of haptic robotic technology in one patient with six implants placed in the maxilla and five implants in the lower mandible with the goal of individual single implant supported crowns to be placed over each implant after 6 months. All implants were placed using a flapless technique, with one immediate implant placement after extraction. All implants were placed with a high degree of accuracy relative to the pre-operative plan as determined by post-op CBCT analysis with an average angular deviation of 2.58° and positional deviations at the coronal and apical aspects of the implant around 1 mm (0.93 and 1.06 mm, respectively). Total surgical time of less than 2 h. Haptic robotics physically guides the location, orientation, and depth of the tools during both drilling and implantation and thus allows for accurate placement as well as the intra-operative flexibility to change the plan as necessary while providing excellent visualization and irrigation. This robotic technology provides a treatment that focuses on accuracy and safety providing the best chance at excellent surgical outcomes for the patient.</p>","PeriodicalId":50679,"journal":{"name":"Clinical Implant Dentistry and Related Research","volume":"26 2","pages":"251-257"},"PeriodicalIF":3.7000,"publicationDate":"2023-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/cid.13279","citationCount":"0","resultStr":"{\"title\":\"Flapless dental implant surgery enabled by haptic robotic guidance: A case report\",\"authors\":\"Mohamed Ali DDS\",\"doi\":\"10.1111/cid.13279\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>This case report presents the use of haptic robotic technology in one patient with six implants placed in the maxilla and five implants in the lower mandible with the goal of individual single implant supported crowns to be placed over each implant after 6 months. All implants were placed using a flapless technique, with one immediate implant placement after extraction. All implants were placed with a high degree of accuracy relative to the pre-operative plan as determined by post-op CBCT analysis with an average angular deviation of 2.58° and positional deviations at the coronal and apical aspects of the implant around 1 mm (0.93 and 1.06 mm, respectively). Total surgical time of less than 2 h. Haptic robotics physically guides the location, orientation, and depth of the tools during both drilling and implantation and thus allows for accurate placement as well as the intra-operative flexibility to change the plan as necessary while providing excellent visualization and irrigation. This robotic technology provides a treatment that focuses on accuracy and safety providing the best chance at excellent surgical outcomes for the patient.</p>\",\"PeriodicalId\":50679,\"journal\":{\"name\":\"Clinical Implant Dentistry and Related Research\",\"volume\":\"26 2\",\"pages\":\"251-257\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2023-10-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1111/cid.13279\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Implant Dentistry and Related Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/cid.13279\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Implant Dentistry and Related Research","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/cid.13279","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Flapless dental implant surgery enabled by haptic robotic guidance: A case report
This case report presents the use of haptic robotic technology in one patient with six implants placed in the maxilla and five implants in the lower mandible with the goal of individual single implant supported crowns to be placed over each implant after 6 months. All implants were placed using a flapless technique, with one immediate implant placement after extraction. All implants were placed with a high degree of accuracy relative to the pre-operative plan as determined by post-op CBCT analysis with an average angular deviation of 2.58° and positional deviations at the coronal and apical aspects of the implant around 1 mm (0.93 and 1.06 mm, respectively). Total surgical time of less than 2 h. Haptic robotics physically guides the location, orientation, and depth of the tools during both drilling and implantation and thus allows for accurate placement as well as the intra-operative flexibility to change the plan as necessary while providing excellent visualization and irrigation. This robotic technology provides a treatment that focuses on accuracy and safety providing the best chance at excellent surgical outcomes for the patient.
期刊介绍:
The goal of Clinical Implant Dentistry and Related Research is to advance the scientific and technical aspects relating to dental implants and related scientific subjects. Dissemination of new and evolving information related to dental implants and the related science is the primary goal of our journal.
The range of topics covered by the journals will include but be not limited to:
New scientific developments relating to bone
Implant surfaces and their relationship to the surrounding tissues
Computer aided implant designs
Computer aided prosthetic designs
Immediate implant loading
Immediate implant placement
Materials relating to bone induction and conduction
New surgical methods relating to implant placement
New materials and methods relating to implant restorations
Methods for determining implant stability
A primary focus of the journal is publication of evidenced based articles evaluating to new dental implants, techniques and multicenter studies evaluating these treatments. In addition basic science research relating to wound healing and osseointegration will be an important focus for the journal.