Benjamin Rodriguez, Peter Campbell, Joseph Borrello, Ian Odland, Tyree Williams, Eugene I Hrabarchuk, Tirone Young, Anirudh Sharma, Alexander J Schupper, Benjamin Rapoport, Robert Ivkov, Constantinos Hadjipanayis
{"title":"一种促进胶质瘤磁热疗的新型端口。","authors":"Benjamin Rodriguez, Peter Campbell, Joseph Borrello, Ian Odland, Tyree Williams, Eugene I Hrabarchuk, Tirone Young, Anirudh Sharma, Alexander J Schupper, Benjamin Rapoport, Robert Ivkov, Constantinos Hadjipanayis","doi":"10.1115/1.4063556","DOIUrl":null,"url":null,"abstract":"<p><p>High-grade gliomas (HGG) are the most common primary brain malignancy and continue to be associated with a dismal prognosis (median survival rate of 15-18 months) with standard of care therapy. Magnetic hyperthermia therapy (MHT) is an emerging intervention that leverages the ferromagnetic properties of magnetic iron-oxide nanoparticles (MIONPs) to target cancer cells that are otherwise left behind after resection. We report a novel port device to facilitate localization, delivery, and temperature measurement of MIONPs within a target lesion for MHT therapy. We conducted an in-depth literature and intellectual property review to define specifications of the conceived port device. After setting the design parameters, a thorough collaboration with neurological surgeons guided the iterative modeling process. A prototype was developed using Fusion 360 (Autodesk, San Rafael, CA) and printed on a Form 3 printer (Formlabs, Medford, MA) in Durable resin. The prototype was then tested in a phantom skull printed on a Pro-Jet 660Pro 3D printer (3D Systems, Rock Hill, SC) and a brain model based on mechanical and electrochemical properties of native brain tissue. This phantom underwent MHT heating tests using an alternating magnetic field (AMF) sequence based on current MHT workflow. Successful localization, delivery, and temperature measurement were demonstrated. The purpose of this study was twofold: first, to create and validate the procedural framework for a novel device, providing the groundwork for an upcoming comprehensive animal trial and second, to elucidate a cooperative approach between engineers and clinicians that propels advancements in medical innovation.</p>","PeriodicalId":54871,"journal":{"name":"Journal of Biomechanical Engineering-Transactions of the Asme","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Novel Port to Facilitate Magnetic Hyperthermia Therapy for Glioma.\",\"authors\":\"Benjamin Rodriguez, Peter Campbell, Joseph Borrello, Ian Odland, Tyree Williams, Eugene I Hrabarchuk, Tirone Young, Anirudh Sharma, Alexander J Schupper, Benjamin Rapoport, Robert Ivkov, Constantinos Hadjipanayis\",\"doi\":\"10.1115/1.4063556\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>High-grade gliomas (HGG) are the most common primary brain malignancy and continue to be associated with a dismal prognosis (median survival rate of 15-18 months) with standard of care therapy. Magnetic hyperthermia therapy (MHT) is an emerging intervention that leverages the ferromagnetic properties of magnetic iron-oxide nanoparticles (MIONPs) to target cancer cells that are otherwise left behind after resection. We report a novel port device to facilitate localization, delivery, and temperature measurement of MIONPs within a target lesion for MHT therapy. We conducted an in-depth literature and intellectual property review to define specifications of the conceived port device. After setting the design parameters, a thorough collaboration with neurological surgeons guided the iterative modeling process. A prototype was developed using Fusion 360 (Autodesk, San Rafael, CA) and printed on a Form 3 printer (Formlabs, Medford, MA) in Durable resin. The prototype was then tested in a phantom skull printed on a Pro-Jet 660Pro 3D printer (3D Systems, Rock Hill, SC) and a brain model based on mechanical and electrochemical properties of native brain tissue. This phantom underwent MHT heating tests using an alternating magnetic field (AMF) sequence based on current MHT workflow. Successful localization, delivery, and temperature measurement were demonstrated. The purpose of this study was twofold: first, to create and validate the procedural framework for a novel device, providing the groundwork for an upcoming comprehensive animal trial and second, to elucidate a cooperative approach between engineers and clinicians that propels advancements in medical innovation.</p>\",\"PeriodicalId\":54871,\"journal\":{\"name\":\"Journal of Biomechanical Engineering-Transactions of the Asme\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Biomechanical Engineering-Transactions of the Asme\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4063556\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomechanical Engineering-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4063556","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOPHYSICS","Score":null,"Total":0}
A Novel Port to Facilitate Magnetic Hyperthermia Therapy for Glioma.
High-grade gliomas (HGG) are the most common primary brain malignancy and continue to be associated with a dismal prognosis (median survival rate of 15-18 months) with standard of care therapy. Magnetic hyperthermia therapy (MHT) is an emerging intervention that leverages the ferromagnetic properties of magnetic iron-oxide nanoparticles (MIONPs) to target cancer cells that are otherwise left behind after resection. We report a novel port device to facilitate localization, delivery, and temperature measurement of MIONPs within a target lesion for MHT therapy. We conducted an in-depth literature and intellectual property review to define specifications of the conceived port device. After setting the design parameters, a thorough collaboration with neurological surgeons guided the iterative modeling process. A prototype was developed using Fusion 360 (Autodesk, San Rafael, CA) and printed on a Form 3 printer (Formlabs, Medford, MA) in Durable resin. The prototype was then tested in a phantom skull printed on a Pro-Jet 660Pro 3D printer (3D Systems, Rock Hill, SC) and a brain model based on mechanical and electrochemical properties of native brain tissue. This phantom underwent MHT heating tests using an alternating magnetic field (AMF) sequence based on current MHT workflow. Successful localization, delivery, and temperature measurement were demonstrated. The purpose of this study was twofold: first, to create and validate the procedural framework for a novel device, providing the groundwork for an upcoming comprehensive animal trial and second, to elucidate a cooperative approach between engineers and clinicians that propels advancements in medical innovation.
期刊介绍:
Artificial Organs and Prostheses; Bioinstrumentation and Measurements; Bioheat Transfer; Biomaterials; Biomechanics; Bioprocess Engineering; Cellular Mechanics; Design and Control of Biological Systems; Physiological Systems.