青少年舞蹈运动员等长中大腿提拉的可靠性、变异性和最小可检测变化。

IF 1.1 Q3 SPORT SCIENCES Journal of Dance Medicine & Science Pub Date : 2024-03-01 Epub Date: 2023-09-26 DOI:10.1177/1089313X231198421
Nico Kolokythas, George S Metsios, Shaun M Galloway, Nick Allen, Matthew A Wyon
{"title":"青少年舞蹈运动员等长中大腿提拉的可靠性、变异性和最小可检测变化。","authors":"Nico Kolokythas, George S Metsios, Shaun M Galloway, Nick Allen, Matthew A Wyon","doi":"10.1177/1089313X231198421","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The importance and potential benefits of muscular strength in the adolescent's development for health and fitness has been demonstrated in the literature. Maximal muscular strength and its assessment, however, is not a primary assessment criterium in the selection of young talented dancers.</p><p><strong>Methods: </strong>The present study evaluated the within- and between session reliability, variability, and minimal detectable change (MDC) of the isometric mid-thigh pull (IMTP). Thirty-five participants (female n = 17) participated in 2 identical assessments on the same day with 4-hour break in between. Three 3-second IMTP were performed, and the mean peak force value was used for the analyses.</p><p><strong>Results: </strong>Within-session the ICC indicated excellent reliability (ICC = .99, 95% CI: 0.98-0.99). Between-session reliability was excellent (ICC = .98, 95% CI: 0.95-0.99). The standard error of measurement was 4% (48 N), the minimum detectable change was 12% (134 N) and the CV was 3%. There were no within-session statistically significant differences, but statistically significant differences between-session were observed (<i>P</i> < .001). Limits of agreement ranged from -121 N (95% CI -186 to -56 N) to 307 N (95% CI 243-372 N).</p><p><strong>Conclusion: </strong>The observed results demonstrated excellent within- and between sessions reliability, low variability, and an MDC of 12%. The consistency of the within-session scores suggest that peak force data may be obtained with single try efforts. The statistically significant difference in the means of the retest session, however, suggests that the time of the day or the time since entrained awakening may be affecting performance in adolescent dancers. The results of the current study indicate that the IMTP is a reliable assessment tool for maximal muscular strength in adolescent dancers.</p>","PeriodicalId":46421,"journal":{"name":"Journal of Dance Medicine & Science","volume":" ","pages":"14-20"},"PeriodicalIF":1.1000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reliability, Variability and Minimal Detectable Change of the Isometric Mid-Thigh Pull in Adolescent Dancers.\",\"authors\":\"Nico Kolokythas, George S Metsios, Shaun M Galloway, Nick Allen, Matthew A Wyon\",\"doi\":\"10.1177/1089313X231198421\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The importance and potential benefits of muscular strength in the adolescent's development for health and fitness has been demonstrated in the literature. Maximal muscular strength and its assessment, however, is not a primary assessment criterium in the selection of young talented dancers.</p><p><strong>Methods: </strong>The present study evaluated the within- and between session reliability, variability, and minimal detectable change (MDC) of the isometric mid-thigh pull (IMTP). Thirty-five participants (female n = 17) participated in 2 identical assessments on the same day with 4-hour break in between. Three 3-second IMTP were performed, and the mean peak force value was used for the analyses.</p><p><strong>Results: </strong>Within-session the ICC indicated excellent reliability (ICC = .99, 95% CI: 0.98-0.99). Between-session reliability was excellent (ICC = .98, 95% CI: 0.95-0.99). The standard error of measurement was 4% (48 N), the minimum detectable change was 12% (134 N) and the CV was 3%. There were no within-session statistically significant differences, but statistically significant differences between-session were observed (<i>P</i> < .001). Limits of agreement ranged from -121 N (95% CI -186 to -56 N) to 307 N (95% CI 243-372 N).</p><p><strong>Conclusion: </strong>The observed results demonstrated excellent within- and between sessions reliability, low variability, and an MDC of 12%. The consistency of the within-session scores suggest that peak force data may be obtained with single try efforts. The statistically significant difference in the means of the retest session, however, suggests that the time of the day or the time since entrained awakening may be affecting performance in adolescent dancers. The results of the current study indicate that the IMTP is a reliable assessment tool for maximal muscular strength in adolescent dancers.</p>\",\"PeriodicalId\":46421,\"journal\":{\"name\":\"Journal of Dance Medicine & Science\",\"volume\":\" \",\"pages\":\"14-20\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Dance Medicine & Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/1089313X231198421\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/9/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"SPORT SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dance Medicine & Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1089313X231198421","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/26 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"SPORT SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

引言:文献中已经证明了肌肉力量在青少年健康和健身发展中的重要性和潜在益处。然而,最大肌肉力量及其评估并不是选拔年轻天才舞者的主要评估标准。方法:本研究评估了等长大腿中部提拉(IMTP)的会话内和会话间可靠性、变异性和最小可检测变化(MDC)。35名参与者(女性n = 17) 在同一天参加了两次相同的评估,其间休息4小时。进行了三次3秒的IMTP,并使用平均峰值力值进行分析。结果:在会话中,ICC显示出优异的可靠性(ICC = .99.95%可信区间:0.98-0.99)。会话间可靠性极佳(ICC = .98.95%可信区间:0.95-0.99)。测量的标准误差为4%(48 N) ,最小可检测变化为12%(134 N) CV为3%。疗程内无统计学显著差异,但疗程间有统计学显著差异(P 结论:观察结果显示了良好的会话内和会话间可靠性、低变异性和12%的MDC。会话内得分的一致性表明,可以通过单次尝试获得峰值力数据。然而,重新测试的平均值在统计上存在显著差异,这表明一天中的时间或自苏醒以来的时间可能会影响青少年舞者的表现。目前的研究结果表明,IMTP是评估青少年舞者最大肌肉力量的可靠工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reliability, Variability and Minimal Detectable Change of the Isometric Mid-Thigh Pull in Adolescent Dancers.

Introduction: The importance and potential benefits of muscular strength in the adolescent's development for health and fitness has been demonstrated in the literature. Maximal muscular strength and its assessment, however, is not a primary assessment criterium in the selection of young talented dancers.

Methods: The present study evaluated the within- and between session reliability, variability, and minimal detectable change (MDC) of the isometric mid-thigh pull (IMTP). Thirty-five participants (female n = 17) participated in 2 identical assessments on the same day with 4-hour break in between. Three 3-second IMTP were performed, and the mean peak force value was used for the analyses.

Results: Within-session the ICC indicated excellent reliability (ICC = .99, 95% CI: 0.98-0.99). Between-session reliability was excellent (ICC = .98, 95% CI: 0.95-0.99). The standard error of measurement was 4% (48 N), the minimum detectable change was 12% (134 N) and the CV was 3%. There were no within-session statistically significant differences, but statistically significant differences between-session were observed (P < .001). Limits of agreement ranged from -121 N (95% CI -186 to -56 N) to 307 N (95% CI 243-372 N).

Conclusion: The observed results demonstrated excellent within- and between sessions reliability, low variability, and an MDC of 12%. The consistency of the within-session scores suggest that peak force data may be obtained with single try efforts. The statistically significant difference in the means of the retest session, however, suggests that the time of the day or the time since entrained awakening may be affecting performance in adolescent dancers. The results of the current study indicate that the IMTP is a reliable assessment tool for maximal muscular strength in adolescent dancers.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.80
自引率
11.10%
发文量
33
期刊最新文献
Cueing Dancers to "Externally Rotate From the Hips" Improves Potentially Injurious Ankle Joint Angles and Contact Forces During a Demipointe Ballet Position. A 12-Week Ballroom Dance Training Improves Physical Fitness Performance More Than Walking Training in Older Women, Regardless of Vitamin B12 or D Adequacy. An Evaluation of the Sharing Dance Public School Program on Physical Literacy. "A Letter of Appreciation and Suggestions: Improving Methodological Rigor and Questionnaire Design in Ballet Dance Injury Research". Evaluation of the Physiological and Psychological Impact of Ballet Performances Across Age Cohorts: An Observational Uncontrolled Case Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1