用于靶向前列腺活检的机器人工具的远程操作和自动控制。

Journal of medical robotics research Pub Date : 2023-03-01 Epub Date: 2023-03-18 DOI:10.1142/s2424905x23400020
Blayton Padasdao, Samuel Lafreniere, Mahsa Rabiei, Zolboo Batsaikhan, Bardia Konh
{"title":"用于靶向前列腺活检的机器人工具的远程操作和自动控制。","authors":"Blayton Padasdao,&nbsp;Samuel Lafreniere,&nbsp;Mahsa Rabiei,&nbsp;Zolboo Batsaikhan,&nbsp;Bardia Konh","doi":"10.1142/s2424905x23400020","DOIUrl":null,"url":null,"abstract":"<p><p>This work presents a robotic tool with bidirectional manipulation and control capabilities for targeted prostate biopsy interventions. Targeted prostate biopsy is an effective image-guided technique that results in detection of significant cancer with fewer cores and lower number of unnecessary biopsies compared to systematic biopsy. The robotic tool comprises of a compliant flexure section fabricated on a nitinol tube that enables bidirectional bending via actuation of two internal tendons, and a biopsy mechanism for extraction of tissue samples. The kinematic and static models of the compliant flexure section, as well as teleoperated and automated control of the robotic tool are presented and validated with experiments. It was shown that the controller can force the tip of the robotic tool to follow sinusoidal set-point positions with reasonable accuracy in air and inside a phantom tissue. Finally, the capability of the robotic tool to bend, reach targeted positions inside a phantom tissue, and extract a biopsy sample is evaluated.</p>","PeriodicalId":73821,"journal":{"name":"Journal of medical robotics research","volume":"8 1-amp 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10513146/pdf/nihms-1878856.pdf","citationCount":"3","resultStr":"{\"title\":\"Teleoperated and Automated Control of a Robotic Tool for Targeted Prostate Biopsy.\",\"authors\":\"Blayton Padasdao,&nbsp;Samuel Lafreniere,&nbsp;Mahsa Rabiei,&nbsp;Zolboo Batsaikhan,&nbsp;Bardia Konh\",\"doi\":\"10.1142/s2424905x23400020\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This work presents a robotic tool with bidirectional manipulation and control capabilities for targeted prostate biopsy interventions. Targeted prostate biopsy is an effective image-guided technique that results in detection of significant cancer with fewer cores and lower number of unnecessary biopsies compared to systematic biopsy. The robotic tool comprises of a compliant flexure section fabricated on a nitinol tube that enables bidirectional bending via actuation of two internal tendons, and a biopsy mechanism for extraction of tissue samples. The kinematic and static models of the compliant flexure section, as well as teleoperated and automated control of the robotic tool are presented and validated with experiments. It was shown that the controller can force the tip of the robotic tool to follow sinusoidal set-point positions with reasonable accuracy in air and inside a phantom tissue. Finally, the capability of the robotic tool to bend, reach targeted positions inside a phantom tissue, and extract a biopsy sample is evaluated.</p>\",\"PeriodicalId\":73821,\"journal\":{\"name\":\"Journal of medical robotics research\",\"volume\":\"8 1-amp 2\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10513146/pdf/nihms-1878856.pdf\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of medical robotics research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1142/s2424905x23400020\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/3/18 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of medical robotics research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1142/s2424905x23400020","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/3/18 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

这项工作提出了一种具有双向操作和控制能力的机器人工具,用于靶向前列腺活检干预。靶向前列腺活组织检查是一种有效的图像引导技术,与系统活组织检查相比,它可以检测到显著的癌症,核心更少,不必要的活组织检查次数更少。该机器人工具包括在镍钛诺管上制造的柔性弯曲部分和用于提取组织样本的活检机构,该柔性弯曲部分能够通过致动两个内部肌腱实现双向弯曲。给出了柔性柔性段的运动学和静态模型,以及机器人工具的遥操作和自动控制,并通过实验进行了验证。结果表明,该控制器可以迫使机器人工具的尖端在空气中和体模组织内部以合理的精度遵循正弦设定点位置。最后,评估了机器人工具弯曲、到达体模组织内目标位置和提取活检样本的能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Teleoperated and Automated Control of a Robotic Tool for Targeted Prostate Biopsy.

This work presents a robotic tool with bidirectional manipulation and control capabilities for targeted prostate biopsy interventions. Targeted prostate biopsy is an effective image-guided technique that results in detection of significant cancer with fewer cores and lower number of unnecessary biopsies compared to systematic biopsy. The robotic tool comprises of a compliant flexure section fabricated on a nitinol tube that enables bidirectional bending via actuation of two internal tendons, and a biopsy mechanism for extraction of tissue samples. The kinematic and static models of the compliant flexure section, as well as teleoperated and automated control of the robotic tool are presented and validated with experiments. It was shown that the controller can force the tip of the robotic tool to follow sinusoidal set-point positions with reasonable accuracy in air and inside a phantom tissue. Finally, the capability of the robotic tool to bend, reach targeted positions inside a phantom tissue, and extract a biopsy sample is evaluated.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.10
自引率
0.00%
发文量
0
期刊最新文献
Comparative Analysis of Peltier Devices and Flexible Heater Strips for Enhancing Bandwidth in Thermo-Active Soft Actuators Robotic Assistance and Haptic Feedback in Arthroscopic Procedures: Design and Preliminary Evaluation of a Two-Arm System Closed-form kinematics solutions for redundant medical robots with joint limits and singularity avoidance Development and preliminary evaluation of a robotic device for MRI-guided needle breast biopsy An MRI-Conditional Flexible Endoscopic Robot with a Hydraulic Tendon-Driven Actuation System
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1