锥束计算机断层扫描对牙槽后上动脉的解剖学评估:一项系统综述和荟萃分析。

IF 1.7 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Imaging Science in Dentistry Pub Date : 2023-09-01 Epub Date: 2023-08-02 DOI:10.5624/isd.20230009
Faraz Radmand, Tahmineh Razi, Milad Baseri, Leili Faraji Gavgani, Fatemeh Salehnia, Masoumeh Faramarzi
{"title":"锥束计算机断层扫描对牙槽后上动脉的解剖学评估:一项系统综述和荟萃分析。","authors":"Faraz Radmand,&nbsp;Tahmineh Razi,&nbsp;Milad Baseri,&nbsp;Leili Faraji Gavgani,&nbsp;Fatemeh Salehnia,&nbsp;Masoumeh Faramarzi","doi":"10.5624/isd.20230009","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This systematic review examined the detection of the posterior superior alveolar artery, along with various anatomic characteristics, on cone-beam computed tomography images.</p><p><strong>Materials and methods: </strong>Studies were identified electronically through the Web of Science, MEDLINE, Scopus, and Embase databases. The quality of the included studies was evaluated using a 5-item binary scale. The detection rate, location, and classified diameter of the posterior superior alveolar artery were estimated as prevalence values. The diameter of this artery, as well as the distances from the artery to the alveolar crest and sinus floor, were estimated as means with associated 95% confidence intervals.</p><p><strong>Results: </strong>Thirty-seven studies were enrolled, with 34 of these included in the meta-analysis. The mean detection rate was 79% (range: 72%-84%), and the mean diameter was 1.06±0.05 mm (range: 0.96-1.16 mm). The posterior superior alveolar artery was located intraosseously in 64% of cases. The mean distance of the artery from the alveolar crest was 16.71±0.49 mm (range: 15.75-17.68 mm), while the mean distance from the artery to the sinus floor was 8.85±0.4 mm (range: 8.05-9.64 mm).</p><p><strong>Conclusion: </strong>According to the findings of this meta-analysis regarding various anatomic characteristics of the posterior superior alveolar artery, severe hemorrhage after damage to this artery during sinus augmentation procedures is not a substantial clinical problem.</p>","PeriodicalId":51714,"journal":{"name":"Imaging Science in Dentistry","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/c0/4d/isd-53-177.PMC10548151.pdf","citationCount":"0","resultStr":"{\"title\":\"Anatomic evaluation of the posterior superior alveolar artery using cone-beam computed tomography: A systematic review and meta-analysis.\",\"authors\":\"Faraz Radmand,&nbsp;Tahmineh Razi,&nbsp;Milad Baseri,&nbsp;Leili Faraji Gavgani,&nbsp;Fatemeh Salehnia,&nbsp;Masoumeh Faramarzi\",\"doi\":\"10.5624/isd.20230009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This systematic review examined the detection of the posterior superior alveolar artery, along with various anatomic characteristics, on cone-beam computed tomography images.</p><p><strong>Materials and methods: </strong>Studies were identified electronically through the Web of Science, MEDLINE, Scopus, and Embase databases. The quality of the included studies was evaluated using a 5-item binary scale. The detection rate, location, and classified diameter of the posterior superior alveolar artery were estimated as prevalence values. The diameter of this artery, as well as the distances from the artery to the alveolar crest and sinus floor, were estimated as means with associated 95% confidence intervals.</p><p><strong>Results: </strong>Thirty-seven studies were enrolled, with 34 of these included in the meta-analysis. The mean detection rate was 79% (range: 72%-84%), and the mean diameter was 1.06±0.05 mm (range: 0.96-1.16 mm). The posterior superior alveolar artery was located intraosseously in 64% of cases. The mean distance of the artery from the alveolar crest was 16.71±0.49 mm (range: 15.75-17.68 mm), while the mean distance from the artery to the sinus floor was 8.85±0.4 mm (range: 8.05-9.64 mm).</p><p><strong>Conclusion: </strong>According to the findings of this meta-analysis regarding various anatomic characteristics of the posterior superior alveolar artery, severe hemorrhage after damage to this artery during sinus augmentation procedures is not a substantial clinical problem.</p>\",\"PeriodicalId\":51714,\"journal\":{\"name\":\"Imaging Science in Dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/c0/4d/isd-53-177.PMC10548151.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Imaging Science in Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5624/isd.20230009\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/8/2 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Imaging Science in Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5624/isd.20230009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/2 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本系统综述检查了锥束计算机断层扫描图像上牙槽后上动脉的检测以及各种解剖特征。材料和方法:研究通过Web of Science、MEDLINE、Scopus和Embase数据库进行电子鉴定。纳入研究的质量采用5项二元量表进行评估。肺泡后上动脉的检出率、位置和分类直径被估计为患病率值。该动脉的直径以及从动脉到牙槽嵴和窦底的距离被估计为相关95%置信区间的平均值。结果:37项研究入选,其中34项纳入荟萃分析。平均检出率为79%(范围:72%-84%),平均直径为1.06±0.05mm(范围:0.96-1.16mm)。64%的病例牙槽后上动脉位于骨内。动脉与牙槽嵴的平均距离为16.71±0.49mm(范围:15.75-17.68mm),而动脉与窦底的平均距离则为8.85±0.4mm(范围:8.05-9.64mm),在鼻窦扩张手术中,该动脉受损后的严重出血并不是一个实质性的临床问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Anatomic evaluation of the posterior superior alveolar artery using cone-beam computed tomography: A systematic review and meta-analysis.

Purpose: This systematic review examined the detection of the posterior superior alveolar artery, along with various anatomic characteristics, on cone-beam computed tomography images.

Materials and methods: Studies were identified electronically through the Web of Science, MEDLINE, Scopus, and Embase databases. The quality of the included studies was evaluated using a 5-item binary scale. The detection rate, location, and classified diameter of the posterior superior alveolar artery were estimated as prevalence values. The diameter of this artery, as well as the distances from the artery to the alveolar crest and sinus floor, were estimated as means with associated 95% confidence intervals.

Results: Thirty-seven studies were enrolled, with 34 of these included in the meta-analysis. The mean detection rate was 79% (range: 72%-84%), and the mean diameter was 1.06±0.05 mm (range: 0.96-1.16 mm). The posterior superior alveolar artery was located intraosseously in 64% of cases. The mean distance of the artery from the alveolar crest was 16.71±0.49 mm (range: 15.75-17.68 mm), while the mean distance from the artery to the sinus floor was 8.85±0.4 mm (range: 8.05-9.64 mm).

Conclusion: According to the findings of this meta-analysis regarding various anatomic characteristics of the posterior superior alveolar artery, severe hemorrhage after damage to this artery during sinus augmentation procedures is not a substantial clinical problem.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Imaging Science in Dentistry
Imaging Science in Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.90
自引率
11.10%
发文量
42
期刊最新文献
Classification of mandibular molar furcation involvement in periapical radiographs by deep learning. Clinical validity and precision of deep learning-based cone-beam computed tomography automatic landmarking algorithm. Combination of metal artifact reduction and sharpening filter application for horizontal root fracture diagnosis in teeth adjacent to a zirconia implant. Erratum to: McCune-Albright syndrome with acromegaly: A case report with characteristic radiographic features of fibrous dysplasia. Evaluation of deep learning and convolutional neural network algorithms for mandibular fracture detection using radiographic images: A systematic review and meta-analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1