2023年的并行网络概念。

IF 4.3 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC ACS Applied Electronic Materials Pub Date : 2023-09-28 Epub Date: 2023-07-20 DOI:10.21037/acs-2023-scp-15
Suguru Ohira, Steven L Lansman, David Spielvogel
{"title":"2023年的并行网络概念。","authors":"Suguru Ohira,&nbsp;Steven L Lansman,&nbsp;David Spielvogel","doi":"10.21037/acs-2023-scp-15","DOIUrl":null,"url":null,"abstract":"<p><p>Extensive thoracoabdominal aortic aneurysm repair can cause spinal cord ischemia which significantly impacts survival and quality of life. Although this complication is uncommon, it is important to recognize the pathophysiology and preventative measures. In the 1990s, Dr. Griepp and colleagues proposed the existence of an extensive collateral network that supports spinal cord perfusion, \"the collateral network concept\". This includes an interconnecting complex of vessels in the intraspinal, paraspinous, and epidural spaces, and in the paravertebral muscles, involving the intercostal and lumbar segmental arteries as well as the subclavian and hypogastric (iliac) arteries. In this concept, as opposed to the one major segmental input model such as the Adamkiewicz artery, recognition of the importance of multiple inputs to the spinal circulation is paramount to maintaining the spinal blood flow and preventing spinal cord ischemia. In this article, we review the current evidence of the collateral concept and its application in aortic surgery.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2023-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/62/b7/acs-12-05-450.PMC10561329.pdf","citationCount":"0","resultStr":"{\"title\":\"Collateral network concept in 2023.\",\"authors\":\"Suguru Ohira,&nbsp;Steven L Lansman,&nbsp;David Spielvogel\",\"doi\":\"10.21037/acs-2023-scp-15\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Extensive thoracoabdominal aortic aneurysm repair can cause spinal cord ischemia which significantly impacts survival and quality of life. Although this complication is uncommon, it is important to recognize the pathophysiology and preventative measures. In the 1990s, Dr. Griepp and colleagues proposed the existence of an extensive collateral network that supports spinal cord perfusion, \\\"the collateral network concept\\\". This includes an interconnecting complex of vessels in the intraspinal, paraspinous, and epidural spaces, and in the paravertebral muscles, involving the intercostal and lumbar segmental arteries as well as the subclavian and hypogastric (iliac) arteries. In this concept, as opposed to the one major segmental input model such as the Adamkiewicz artery, recognition of the importance of multiple inputs to the spinal circulation is paramount to maintaining the spinal blood flow and preventing spinal cord ischemia. In this article, we review the current evidence of the collateral concept and its application in aortic surgery.</p>\",\"PeriodicalId\":3,\"journal\":{\"name\":\"ACS Applied Electronic Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2023-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/62/b7/acs-12-05-450.PMC10561329.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Electronic Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.21037/acs-2023-scp-15\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/7/20 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.21037/acs-2023-scp-15","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/20 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

广泛的胸腹主动脉瘤修复可导致脊髓缺血,从而显著影响生存率和生活质量。尽管这种并发症并不常见,但认识到病理生理学和预防措施是很重要的。20世纪90年代,Griepp博士及其同事提出了一种支持脊髓灌注的广泛侧支网络的存在,即“侧支网络概念”。这包括椎管内、棘旁和硬膜外间隙以及椎旁肌中的相互连接的血管复合体,涉及肋间和腰段动脉以及锁骨下和腹下(髂)动脉。在这个概念中,与Adamkiewicz动脉等一个主要节段输入模型不同,认识到多个输入对脊柱循环的重要性对于维持脊柱血流和防止脊髓缺血至关重要。在这篇文章中,我们回顾了侧支概念及其在主动脉手术中的应用的最新证据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Collateral network concept in 2023.

Extensive thoracoabdominal aortic aneurysm repair can cause spinal cord ischemia which significantly impacts survival and quality of life. Although this complication is uncommon, it is important to recognize the pathophysiology and preventative measures. In the 1990s, Dr. Griepp and colleagues proposed the existence of an extensive collateral network that supports spinal cord perfusion, "the collateral network concept". This includes an interconnecting complex of vessels in the intraspinal, paraspinous, and epidural spaces, and in the paravertebral muscles, involving the intercostal and lumbar segmental arteries as well as the subclavian and hypogastric (iliac) arteries. In this concept, as opposed to the one major segmental input model such as the Adamkiewicz artery, recognition of the importance of multiple inputs to the spinal circulation is paramount to maintaining the spinal blood flow and preventing spinal cord ischemia. In this article, we review the current evidence of the collateral concept and its application in aortic surgery.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
期刊最新文献
Hyperbaric oxygen treatment promotes tendon-bone interface healing in a rabbit model of rotator cuff tears. Oxygen-ozone therapy for myocardial ischemic stroke and cardiovascular disorders. Comparative study on the anti-inflammatory and protective effects of different oxygen therapy regimens on lipopolysaccharide-induced acute lung injury in mice. Heme oxygenase/carbon monoxide system and development of the heart. Hyperbaric oxygen for moderate-to-severe traumatic brain injury: outcomes 5-8 years after injury.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1