Junhwan Kwon;Oyun Kwon;Kyeong Taek Oh;Jeongmin Kim;Sun K. Yoo
{"title":"用于基于热像仪的间接呼吸监测的呼吸相关面部区域分割。","authors":"Junhwan Kwon;Oyun Kwon;Kyeong Taek Oh;Jeongmin Kim;Sun K. Yoo","doi":"10.1109/JTEHM.2023.3295775","DOIUrl":null,"url":null,"abstract":"Breathing can be measured in a non-contact method using a thermal camera. The objective of this study investigates non-contact breathing measurements using thermal cameras, which have previously been limited to measuring the nostril only from the front where it is clearly visible. The previous method is challenging to use for other angles and frontal views, where the nostril is not well-represented. In this paper, we defined a new region called the breathing-associated-facial-region (BAFR) that reflects the physiological characteristics of breathing, and extract breathing signals from views of 45 and 90 degrees, including the frontal view where the nostril is not clearly visible. Experiments were conducted on fifteen healthy subjects in different views, including frontal with and without nostril, 45-degree, and 90-degree views. A thermal camera (A655sc model, FLIR systems) was used for non-contact measurement, and biopac (MP150, Biopac-systems-Inc) was used as a chest breathing reference. The results showed that the proposed algorithm could extract stable breathing signals at various angles and views, achieving an average breathing cycle accuracy of 90.9% when applied compared to 65.6% without proposed algorithm. The average correlation value increases from 0.587 to 0.885. The proposed algorithm can be monitored in a variety of environments and extract the BAFR at diverse angles and views.","PeriodicalId":54255,"journal":{"name":"IEEE Journal of Translational Engineering in Health and Medicine-Jtehm","volume":"11 ","pages":"505-514"},"PeriodicalIF":3.7000,"publicationDate":"2023-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/fa/2d/jtehm-yoo-3295775.PMC10561734.pdf","citationCount":"1","resultStr":"{\"title\":\"Breathing-Associated Facial Region Segmentation for Thermal Camera-Based Indirect Breathing Monitoring\",\"authors\":\"Junhwan Kwon;Oyun Kwon;Kyeong Taek Oh;Jeongmin Kim;Sun K. Yoo\",\"doi\":\"10.1109/JTEHM.2023.3295775\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Breathing can be measured in a non-contact method using a thermal camera. The objective of this study investigates non-contact breathing measurements using thermal cameras, which have previously been limited to measuring the nostril only from the front where it is clearly visible. The previous method is challenging to use for other angles and frontal views, where the nostril is not well-represented. In this paper, we defined a new region called the breathing-associated-facial-region (BAFR) that reflects the physiological characteristics of breathing, and extract breathing signals from views of 45 and 90 degrees, including the frontal view where the nostril is not clearly visible. Experiments were conducted on fifteen healthy subjects in different views, including frontal with and without nostril, 45-degree, and 90-degree views. A thermal camera (A655sc model, FLIR systems) was used for non-contact measurement, and biopac (MP150, Biopac-systems-Inc) was used as a chest breathing reference. The results showed that the proposed algorithm could extract stable breathing signals at various angles and views, achieving an average breathing cycle accuracy of 90.9% when applied compared to 65.6% without proposed algorithm. The average correlation value increases from 0.587 to 0.885. The proposed algorithm can be monitored in a variety of environments and extract the BAFR at diverse angles and views.\",\"PeriodicalId\":54255,\"journal\":{\"name\":\"IEEE Journal of Translational Engineering in Health and Medicine-Jtehm\",\"volume\":\"11 \",\"pages\":\"505-514\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2023-07-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/fa/2d/jtehm-yoo-3295775.PMC10561734.pdf\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Journal of Translational Engineering in Health and Medicine-Jtehm\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10184419/\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Journal of Translational Engineering in Health and Medicine-Jtehm","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10184419/","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Breathing-Associated Facial Region Segmentation for Thermal Camera-Based Indirect Breathing Monitoring
Breathing can be measured in a non-contact method using a thermal camera. The objective of this study investigates non-contact breathing measurements using thermal cameras, which have previously been limited to measuring the nostril only from the front where it is clearly visible. The previous method is challenging to use for other angles and frontal views, where the nostril is not well-represented. In this paper, we defined a new region called the breathing-associated-facial-region (BAFR) that reflects the physiological characteristics of breathing, and extract breathing signals from views of 45 and 90 degrees, including the frontal view where the nostril is not clearly visible. Experiments were conducted on fifteen healthy subjects in different views, including frontal with and without nostril, 45-degree, and 90-degree views. A thermal camera (A655sc model, FLIR systems) was used for non-contact measurement, and biopac (MP150, Biopac-systems-Inc) was used as a chest breathing reference. The results showed that the proposed algorithm could extract stable breathing signals at various angles and views, achieving an average breathing cycle accuracy of 90.9% when applied compared to 65.6% without proposed algorithm. The average correlation value increases from 0.587 to 0.885. The proposed algorithm can be monitored in a variety of environments and extract the BAFR at diverse angles and views.
期刊介绍:
The IEEE Journal of Translational Engineering in Health and Medicine is an open access product that bridges the engineering and clinical worlds, focusing on detailed descriptions of advanced technical solutions to a clinical need along with clinical results and healthcare relevance. The journal provides a platform for state-of-the-art technology directions in the interdisciplinary field of biomedical engineering, embracing engineering, life sciences and medicine. A unique aspect of the journal is its ability to foster a collaboration between physicians and engineers for presenting broad and compelling real world technological and engineering solutions that can be implemented in the interest of improving quality of patient care and treatment outcomes, thereby reducing costs and improving efficiency. The journal provides an active forum for clinical research and relevant state-of the-art technology for members of all the IEEE societies that have an interest in biomedical engineering as well as reaching out directly to physicians and the medical community through the American Medical Association (AMA) and other clinical societies. The scope of the journal includes, but is not limited, to topics on: Medical devices, healthcare delivery systems, global healthcare initiatives, and ICT based services; Technological relevance to healthcare cost reduction; Technology affecting healthcare management, decision-making, and policy; Advanced technical work that is applied to solving specific clinical needs.