{"title":"变异型血红蛋白E表型上检测不到的高效液相色谱法血红蛋白A1c:一例报告。","authors":"Nadia Sadriani, Ferdy Royland Marpaung","doi":"10.11613/BM.2023.030801","DOIUrl":null,"url":null,"abstract":"<p><p>The gold standard for long-term monitoring of diabetic patients is glycated haemoglobin (HbA1c), which is routinely tested for glycaemic control. Furthermore, the National glycohemoglobin standardization program (NGSP) has designated high-performance liquid chromatography (HPLC) as the reference method for HbA1c measurement. A woman from the Sumba tribe, Indonesia, aged 52, visited the Internal Medicine Clinic for a routine check-up. She had been taking diabetic and hypertension medicines on a regular basis for over 10 years. The HPLC procedure yielded \"no result\" for the patient's HbA1c assessment and there was no peak on the HPLC graphic. However, there was a discrepancy between the data history of HbA1c measured by turbidimetric method (average of 51 mmol/mol, reference range < 48 mmol/mol), fasting blood glucose (average of 7.7 mmol/L, reference range < 7.0 mmol/L) and 2-hour plasma glucose (average of 13 mmol/L, reference range < 11.1 mmol/L). Glycated albumin was 3.1 mmol/L (reference range 1.8-2.4 mmol/L). Haemoglobin electrophoresis identified homozygote haemoglobinopathy E (HbE). Patients with haemoglobin variants are proposed to utilize glycated albumin.</p>","PeriodicalId":94370,"journal":{"name":"Biochemia medica","volume":"33 3","pages":"030801"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10564149/pdf/","citationCount":"0","resultStr":"{\"title\":\"Undetectable high-performance liquid chromatography haemoglobin A1c on variant haemoglobin E phenotype: a case report.\",\"authors\":\"Nadia Sadriani, Ferdy Royland Marpaung\",\"doi\":\"10.11613/BM.2023.030801\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The gold standard for long-term monitoring of diabetic patients is glycated haemoglobin (HbA1c), which is routinely tested for glycaemic control. Furthermore, the National glycohemoglobin standardization program (NGSP) has designated high-performance liquid chromatography (HPLC) as the reference method for HbA1c measurement. A woman from the Sumba tribe, Indonesia, aged 52, visited the Internal Medicine Clinic for a routine check-up. She had been taking diabetic and hypertension medicines on a regular basis for over 10 years. The HPLC procedure yielded \\\"no result\\\" for the patient's HbA1c assessment and there was no peak on the HPLC graphic. However, there was a discrepancy between the data history of HbA1c measured by turbidimetric method (average of 51 mmol/mol, reference range < 48 mmol/mol), fasting blood glucose (average of 7.7 mmol/L, reference range < 7.0 mmol/L) and 2-hour plasma glucose (average of 13 mmol/L, reference range < 11.1 mmol/L). Glycated albumin was 3.1 mmol/L (reference range 1.8-2.4 mmol/L). Haemoglobin electrophoresis identified homozygote haemoglobinopathy E (HbE). Patients with haemoglobin variants are proposed to utilize glycated albumin.</p>\",\"PeriodicalId\":94370,\"journal\":{\"name\":\"Biochemia medica\",\"volume\":\"33 3\",\"pages\":\"030801\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10564149/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biochemia medica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11613/BM.2023.030801\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biochemia medica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11613/BM.2023.030801","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Undetectable high-performance liquid chromatography haemoglobin A1c on variant haemoglobin E phenotype: a case report.
The gold standard for long-term monitoring of diabetic patients is glycated haemoglobin (HbA1c), which is routinely tested for glycaemic control. Furthermore, the National glycohemoglobin standardization program (NGSP) has designated high-performance liquid chromatography (HPLC) as the reference method for HbA1c measurement. A woman from the Sumba tribe, Indonesia, aged 52, visited the Internal Medicine Clinic for a routine check-up. She had been taking diabetic and hypertension medicines on a regular basis for over 10 years. The HPLC procedure yielded "no result" for the patient's HbA1c assessment and there was no peak on the HPLC graphic. However, there was a discrepancy between the data history of HbA1c measured by turbidimetric method (average of 51 mmol/mol, reference range < 48 mmol/mol), fasting blood glucose (average of 7.7 mmol/L, reference range < 7.0 mmol/L) and 2-hour plasma glucose (average of 13 mmol/L, reference range < 11.1 mmol/L). Glycated albumin was 3.1 mmol/L (reference range 1.8-2.4 mmol/L). Haemoglobin electrophoresis identified homozygote haemoglobinopathy E (HbE). Patients with haemoglobin variants are proposed to utilize glycated albumin.