不同管电压和造影剂剂量在CT肺血管造影中检测肺血栓栓塞的比较研究

Shaymaa Khalid Abdul-Qader, A. A. Fadhil
{"title":"不同管电压和造影剂剂量在CT肺血管造影中检测肺血栓栓塞的比较研究","authors":"Shaymaa Khalid Abdul-Qader, A. A. Fadhil","doi":"10.47723/kcmj.v18i3.808","DOIUrl":null,"url":null,"abstract":"Background: Lowering the amount of iodinated contrast material and tube voltage may increase pulmonary artery opacification and thrombus identification without compromising picture quality.\nObjectives: To explore the efficiency of using lower tube voltage and a lower contrast medium dose for conducting computed tomography for pulmonary angiography (CTPA) aiming to increase its accuracy in detecting pulmonary thromboembolism (PTE).\nSubjects and Methods:100 patients scheduled for CTPA with a preoperative diagnosis of PTE were grouped into two: group A, (50 patients) got 1 mL/kg at 120 kV and group B, (50 patients) received 0.5 mL/kg at 80 kV.The technique of bolus tracking was implemented.Values of midpoint of multiple pulmonary artery divisions were used to assess attenuation.Significant values are those that exceed 300 Hounsfield units (HU). The dosage of radiation received by the patient, defined as the effective dose, was compared between groups.\nResults: Total mean attenuationdata for the pulmonary arteries have shown to be substantially greater in group-B compared to group-A (39110.4HU vs. 335.97.9HU, P=0.001). Moreover, total dose length product (DLP) values were substantially lower in group-B (934.9 mGy.cm vs. 384.443 mGy.cm, P=0.001). While effective dose values have shown to be significantly lower in group-B (2.90.3 mSv vs. 13.21.8 mSv, P 0.001).\nConclusion: Low-kilovoltage technique and low quantity of iodinated contrast are useful in conducting (CTPA) with high accuracy in detection of pulmonary thromboembolism.","PeriodicalId":34748,"journal":{"name":"mjlh klyh Tb lkndy","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative study on Various Tube Voltages and Contrast Media Doses in CT Pulmonary Angiography to detect Pulmonary Thromboembolism\",\"authors\":\"Shaymaa Khalid Abdul-Qader, A. A. Fadhil\",\"doi\":\"10.47723/kcmj.v18i3.808\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Lowering the amount of iodinated contrast material and tube voltage may increase pulmonary artery opacification and thrombus identification without compromising picture quality.\\nObjectives: To explore the efficiency of using lower tube voltage and a lower contrast medium dose for conducting computed tomography for pulmonary angiography (CTPA) aiming to increase its accuracy in detecting pulmonary thromboembolism (PTE).\\nSubjects and Methods:100 patients scheduled for CTPA with a preoperative diagnosis of PTE were grouped into two: group A, (50 patients) got 1 mL/kg at 120 kV and group B, (50 patients) received 0.5 mL/kg at 80 kV.The technique of bolus tracking was implemented.Values of midpoint of multiple pulmonary artery divisions were used to assess attenuation.Significant values are those that exceed 300 Hounsfield units (HU). The dosage of radiation received by the patient, defined as the effective dose, was compared between groups.\\nResults: Total mean attenuationdata for the pulmonary arteries have shown to be substantially greater in group-B compared to group-A (39110.4HU vs. 335.97.9HU, P=0.001). Moreover, total dose length product (DLP) values were substantially lower in group-B (934.9 mGy.cm vs. 384.443 mGy.cm, P=0.001). While effective dose values have shown to be significantly lower in group-B (2.90.3 mSv vs. 13.21.8 mSv, P 0.001).\\nConclusion: Low-kilovoltage technique and low quantity of iodinated contrast are useful in conducting (CTPA) with high accuracy in detection of pulmonary thromboembolism.\",\"PeriodicalId\":34748,\"journal\":{\"name\":\"mjlh klyh Tb lkndy\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"mjlh klyh Tb lkndy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.47723/kcmj.v18i3.808\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"mjlh klyh Tb lkndy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47723/kcmj.v18i3.808","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:在不影响图像质量的情况下,降低碘化造影剂的量和显像管电压可能会增加肺动脉混浊和血栓识别。目的:探讨使用较低的管电压和较低的造影剂剂量进行肺动脉造影计算机断层扫描(CTPA)的效率,以提高其检测肺血栓栓塞症(PTE)的准确性。受试者和方法:将100名术前诊断为PTE的CTPA患者分为两组:a组,(50例患者)在120kV下给药1mL/kg,B组(50例)在80kV下给药0.5mL/kg。使用多个肺动脉分区的中点值来评估衰减。显著值是指超过300 Hounsfield单位(HU)的值。将患者接受的辐射剂量(定义为有效剂量)在各组之间进行比较。结果:B组肺动脉的总平均衰减数据明显高于A组(39110.4HU对335.97.9HU,P=0.001)。此外,B组的总剂量-长度乘积(DLP)值明显较低(934.9 mGy.cm vs.384.443 mGy.ccm,P=0.001)。而B组的有效剂量值显著较低(2.90.3 mSv vs.13.21.8 mSv,P=0.001血栓栓塞。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparative study on Various Tube Voltages and Contrast Media Doses in CT Pulmonary Angiography to detect Pulmonary Thromboembolism
Background: Lowering the amount of iodinated contrast material and tube voltage may increase pulmonary artery opacification and thrombus identification without compromising picture quality. Objectives: To explore the efficiency of using lower tube voltage and a lower contrast medium dose for conducting computed tomography for pulmonary angiography (CTPA) aiming to increase its accuracy in detecting pulmonary thromboembolism (PTE). Subjects and Methods:100 patients scheduled for CTPA with a preoperative diagnosis of PTE were grouped into two: group A, (50 patients) got 1 mL/kg at 120 kV and group B, (50 patients) received 0.5 mL/kg at 80 kV.The technique of bolus tracking was implemented.Values of midpoint of multiple pulmonary artery divisions were used to assess attenuation.Significant values are those that exceed 300 Hounsfield units (HU). The dosage of radiation received by the patient, defined as the effective dose, was compared between groups. Results: Total mean attenuationdata for the pulmonary arteries have shown to be substantially greater in group-B compared to group-A (39110.4HU vs. 335.97.9HU, P=0.001). Moreover, total dose length product (DLP) values were substantially lower in group-B (934.9 mGy.cm vs. 384.443 mGy.cm, P=0.001). While effective dose values have shown to be significantly lower in group-B (2.90.3 mSv vs. 13.21.8 mSv, P 0.001). Conclusion: Low-kilovoltage technique and low quantity of iodinated contrast are useful in conducting (CTPA) with high accuracy in detection of pulmonary thromboembolism.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.10
自引率
0.00%
发文量
34
审稿时长
12 weeks
期刊最新文献
‘Peacock tail’ Clipping Technique for a Giant Middle Cerebral Artery Aneurysm: A Technical Note Serum Pseudocholinesterase as a Biomarker in the Differentiation between Gastric Cancer and Benign Gastric Diseases Association of HLA-DRB1/DQB1 Alleles and Genetic Susceptibility to Type 1 Diabetes Mellitus The Impact of using the Internet and Social Media on Sleep in a group of Secondary School Students from Baghdad Approach to Manage Congenital Absence of Anterior Cruciate Ligament in a 13 years old Patient – A Rare Case Report of Eastern India
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1