P. Knott, Georgia Csorba, Dustin Bennett, Ryan L. Kift
{"title":"焊接烟尘:工业控制方法的比较研究","authors":"P. Knott, Georgia Csorba, Dustin Bennett, Ryan L. Kift","doi":"10.3390/safety9030042","DOIUrl":null,"url":null,"abstract":"Welding fume is generated during welding activities and is a known cancer-causing hazard for those working in the welding industry. Worker exposure has been shown to regularly exceed the applicable workplace exposure standard, and control measures are required to reduce worker exposure. The aim of this study is to compare the effectiveness of control measures to prevent welding fume exposure to workers. To achieve this aim, three common welding fume control measures (local exhaust ventilation (LEV), powered air purifying respirators (PAPRs) and on-gun extraction) were used during four different welding tasks. Compared to using no controls, LEV hood capture is likely to reduce welding fume concentrations in the breathing zone of a welder by up to a factor of 9. The use of on-gun LEV is likely to reduce welding fume concentrations in the breathing zone of a welder by up to a factor of 12. The 5th percentile effective protection factors of the PAPR for all sampled welding activities were considerably greater than the required minimum protection factor of 50 specified in AS/NZS 1715:2009 for powered air purifying respirators (PAPRs) with class PAPR-P3 particulate filters with any head covering.","PeriodicalId":36827,"journal":{"name":"Safety","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2023-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Welding Fume: A Comparison Study of Industry Used Control Methods\",\"authors\":\"P. Knott, Georgia Csorba, Dustin Bennett, Ryan L. Kift\",\"doi\":\"10.3390/safety9030042\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Welding fume is generated during welding activities and is a known cancer-causing hazard for those working in the welding industry. Worker exposure has been shown to regularly exceed the applicable workplace exposure standard, and control measures are required to reduce worker exposure. The aim of this study is to compare the effectiveness of control measures to prevent welding fume exposure to workers. To achieve this aim, three common welding fume control measures (local exhaust ventilation (LEV), powered air purifying respirators (PAPRs) and on-gun extraction) were used during four different welding tasks. Compared to using no controls, LEV hood capture is likely to reduce welding fume concentrations in the breathing zone of a welder by up to a factor of 9. The use of on-gun LEV is likely to reduce welding fume concentrations in the breathing zone of a welder by up to a factor of 12. The 5th percentile effective protection factors of the PAPR for all sampled welding activities were considerably greater than the required minimum protection factor of 50 specified in AS/NZS 1715:2009 for powered air purifying respirators (PAPRs) with class PAPR-P3 particulate filters with any head covering.\",\"PeriodicalId\":36827,\"journal\":{\"name\":\"Safety\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2023-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Safety\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/safety9030042\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Safety","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/safety9030042","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
Welding Fume: A Comparison Study of Industry Used Control Methods
Welding fume is generated during welding activities and is a known cancer-causing hazard for those working in the welding industry. Worker exposure has been shown to regularly exceed the applicable workplace exposure standard, and control measures are required to reduce worker exposure. The aim of this study is to compare the effectiveness of control measures to prevent welding fume exposure to workers. To achieve this aim, three common welding fume control measures (local exhaust ventilation (LEV), powered air purifying respirators (PAPRs) and on-gun extraction) were used during four different welding tasks. Compared to using no controls, LEV hood capture is likely to reduce welding fume concentrations in the breathing zone of a welder by up to a factor of 9. The use of on-gun LEV is likely to reduce welding fume concentrations in the breathing zone of a welder by up to a factor of 12. The 5th percentile effective protection factors of the PAPR for all sampled welding activities were considerably greater than the required minimum protection factor of 50 specified in AS/NZS 1715:2009 for powered air purifying respirators (PAPRs) with class PAPR-P3 particulate filters with any head covering.