磷酸盐和聚合物涂层对泡沫铁细胞毒性和血液相容性的联合影响

Q4 Materials Science Powder Metallurgy Progress Pub Date : 2021-12-01 DOI:10.2478/pmp-2021-0005
R. Oriňaková, R. Gorejová, Martina Petráková, J. Macko, M. Kupková, M. Hrubovčáková, I. Maskalová
{"title":"磷酸盐和聚合物涂层对泡沫铁细胞毒性和血液相容性的联合影响","authors":"R. Oriňaková, R. Gorejová, Martina Petráková, J. Macko, M. Kupková, M. Hrubovčáková, I. Maskalová","doi":"10.2478/pmp-2021-0005","DOIUrl":null,"url":null,"abstract":"Abstract The use of resorbable metallic biomaterials for temporary implants has increased dramatically in the last decade. Degradable biomaterials are desirable in some specific pediatric, orthopedic, and cardiovascular applications, in which they may overcome the disadvantages of permanent devices. The three main biodegradable metals: Mg, Fe, and Zn, are intensively studied as temporary orthopedic implant materials. Among them, iron, and iron-based alloys, have received attention as promising materials for the temporary replacement of bones, especially for applications where strong mechanical support during the bone healing process is required. The addition of a low amount of phosphorus can improve the mechanical properties of such materials without the risk of retarding the corrosion rate or affecting cell proliferation. The main goal of this work was to study the combined effect of phosphating and polymer coating of open-cell iron foams on their cytotoxicity and hemocompatibility. Obtained results indicated the positive influence of the PEG coating layer and phosphorus addition on material cytocompatibility. Moreover, the combination of these procedures led to the inhibition of hemolysis, platelet adhesion, and thrombus formation.","PeriodicalId":52175,"journal":{"name":"Powder Metallurgy Progress","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Combined Effect of Phosphate and Polymer Coating on Cytotoxicity and Hemocompatibility of Iron Foams\",\"authors\":\"R. Oriňaková, R. Gorejová, Martina Petráková, J. Macko, M. Kupková, M. Hrubovčáková, I. Maskalová\",\"doi\":\"10.2478/pmp-2021-0005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The use of resorbable metallic biomaterials for temporary implants has increased dramatically in the last decade. Degradable biomaterials are desirable in some specific pediatric, orthopedic, and cardiovascular applications, in which they may overcome the disadvantages of permanent devices. The three main biodegradable metals: Mg, Fe, and Zn, are intensively studied as temporary orthopedic implant materials. Among them, iron, and iron-based alloys, have received attention as promising materials for the temporary replacement of bones, especially for applications where strong mechanical support during the bone healing process is required. The addition of a low amount of phosphorus can improve the mechanical properties of such materials without the risk of retarding the corrosion rate or affecting cell proliferation. The main goal of this work was to study the combined effect of phosphating and polymer coating of open-cell iron foams on their cytotoxicity and hemocompatibility. Obtained results indicated the positive influence of the PEG coating layer and phosphorus addition on material cytocompatibility. Moreover, the combination of these procedures led to the inhibition of hemolysis, platelet adhesion, and thrombus formation.\",\"PeriodicalId\":52175,\"journal\":{\"name\":\"Powder Metallurgy Progress\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Powder Metallurgy Progress\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/pmp-2021-0005\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Materials Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Powder Metallurgy Progress","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/pmp-2021-0005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Materials Science","Score":null,"Total":0}
引用次数: 0

摘要

摘要在过去十年中,可吸收金属生物材料在临时植入物中的应用急剧增加。可降解生物材料在一些特定的儿科、骨科和心血管应用中是可取的,在这些应用中,它们可以克服永久性装置的缺点。三种主要的可生物降解金属:镁、铁和锌,作为临时骨科植入材料进行了深入研究。其中,铁和铁基合金作为有前途的骨临时替代材料,特别是在骨愈合过程中需要强大机械支撑的应用中,受到了关注。添加少量的磷可以改善这种材料的机械性能,而没有延缓腐蚀速率或影响细胞增殖的风险。本工作的主要目的是研究开孔泡沫铁的磷化和聚合物涂层对其细胞毒性和血液相容性的联合影响。所得结果表明,PEG涂层和磷的添加对材料的细胞相容性有积极影响。此外,这些程序的结合导致溶血、血小板粘附和血栓形成的抑制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Combined Effect of Phosphate and Polymer Coating on Cytotoxicity and Hemocompatibility of Iron Foams
Abstract The use of resorbable metallic biomaterials for temporary implants has increased dramatically in the last decade. Degradable biomaterials are desirable in some specific pediatric, orthopedic, and cardiovascular applications, in which they may overcome the disadvantages of permanent devices. The three main biodegradable metals: Mg, Fe, and Zn, are intensively studied as temporary orthopedic implant materials. Among them, iron, and iron-based alloys, have received attention as promising materials for the temporary replacement of bones, especially for applications where strong mechanical support during the bone healing process is required. The addition of a low amount of phosphorus can improve the mechanical properties of such materials without the risk of retarding the corrosion rate or affecting cell proliferation. The main goal of this work was to study the combined effect of phosphating and polymer coating of open-cell iron foams on their cytotoxicity and hemocompatibility. Obtained results indicated the positive influence of the PEG coating layer and phosphorus addition on material cytocompatibility. Moreover, the combination of these procedures led to the inhibition of hemolysis, platelet adhesion, and thrombus formation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Powder Metallurgy Progress
Powder Metallurgy Progress Materials Science-Metals and Alloys
CiteScore
1.00
自引率
0.00%
发文量
0
期刊最新文献
Fracture Toughness of Cement Paste Assessed with Micro-Scratch and Acoustic Emission Evaluation of Residual Stress and Tensile Properties of Railway Axle Using Instrumented Indentation Method Announcements: Professor RNDr. Ján Dusza, DrSc – 70 years jubeeleum Effect of Machining on Mechanical Properties of Borosilicate Glasses Micromechanical Properties of Reactive HiTUS TiNbVTaZrHf–N Coatings on Different Substrates
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1