{"title":"基于“心肺相互作用”的无创循环监测指标评价液体反应性的研究进展","authors":"Yi Peng","doi":"10.3760/CMA.J.ISSN.1673-4378.2020.03.013","DOIUrl":null,"url":null,"abstract":"Hitherto, dynamic hemodynamic indicators based on \"heart-lung interactions\" are the gold standard for guiding fluid resuscitation, but such indicators often were obtained by invasive monitoring and complexity process. In recent years, with the emergence of non-invasive methods such as continuous non-invasive arterial pressure (CNAP), hemodynamic monitoring system and ultrasound mon-itoring system were used in clinic, new prospects for the application of heart-lung interactions indicators for volume therapy were opened up. This review describes the dynamic hemodynamics indicators based on \"heart-lung interactions\" measured by CNAP system and ultra-sound monitoring for estimating the volume responsiveness. Application of both methods has certain debate. Non-invasive monitoring for assessing volume responsiveness is the trend of clinical fluid therapy. However, it is not currently recommended to use a non-invasive method to guide fluid therapy because its application conditions are limited. But it can be used as a supplement of invasive monitoring to help doctors perform proper fluid management and reduce adverse events. \n \n \nKey words: \nHeart-lung interactions; Ultrasound; Continuous non-invasive arterial pressure; Fluid responsiveness","PeriodicalId":13847,"journal":{"name":"国际麻醉学与复苏杂志","volume":"41 1","pages":"293-296"},"PeriodicalIF":0.0000,"publicationDate":"2020-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research advances of fluid responsiveness evaluation by non-invasive circulatory monitoring indicators based on \\\"heart-lung interactions\\\"\",\"authors\":\"Yi Peng\",\"doi\":\"10.3760/CMA.J.ISSN.1673-4378.2020.03.013\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Hitherto, dynamic hemodynamic indicators based on \\\"heart-lung interactions\\\" are the gold standard for guiding fluid resuscitation, but such indicators often were obtained by invasive monitoring and complexity process. In recent years, with the emergence of non-invasive methods such as continuous non-invasive arterial pressure (CNAP), hemodynamic monitoring system and ultrasound mon-itoring system were used in clinic, new prospects for the application of heart-lung interactions indicators for volume therapy were opened up. This review describes the dynamic hemodynamics indicators based on \\\"heart-lung interactions\\\" measured by CNAP system and ultra-sound monitoring for estimating the volume responsiveness. Application of both methods has certain debate. Non-invasive monitoring for assessing volume responsiveness is the trend of clinical fluid therapy. However, it is not currently recommended to use a non-invasive method to guide fluid therapy because its application conditions are limited. But it can be used as a supplement of invasive monitoring to help doctors perform proper fluid management and reduce adverse events. \\n \\n \\nKey words: \\nHeart-lung interactions; Ultrasound; Continuous non-invasive arterial pressure; Fluid responsiveness\",\"PeriodicalId\":13847,\"journal\":{\"name\":\"国际麻醉学与复苏杂志\",\"volume\":\"41 1\",\"pages\":\"293-296\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-03-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"国际麻醉学与复苏杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3760/CMA.J.ISSN.1673-4378.2020.03.013\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"国际麻醉学与复苏杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.1673-4378.2020.03.013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research advances of fluid responsiveness evaluation by non-invasive circulatory monitoring indicators based on "heart-lung interactions"
Hitherto, dynamic hemodynamic indicators based on "heart-lung interactions" are the gold standard for guiding fluid resuscitation, but such indicators often were obtained by invasive monitoring and complexity process. In recent years, with the emergence of non-invasive methods such as continuous non-invasive arterial pressure (CNAP), hemodynamic monitoring system and ultrasound mon-itoring system were used in clinic, new prospects for the application of heart-lung interactions indicators for volume therapy were opened up. This review describes the dynamic hemodynamics indicators based on "heart-lung interactions" measured by CNAP system and ultra-sound monitoring for estimating the volume responsiveness. Application of both methods has certain debate. Non-invasive monitoring for assessing volume responsiveness is the trend of clinical fluid therapy. However, it is not currently recommended to use a non-invasive method to guide fluid therapy because its application conditions are limited. But it can be used as a supplement of invasive monitoring to help doctors perform proper fluid management and reduce adverse events.
Key words:
Heart-lung interactions; Ultrasound; Continuous non-invasive arterial pressure; Fluid responsiveness