{"title":"校准流体和校准方程:选择如何影响用u型管密度计进行密度测量的结果。","authors":"S. Outcalt","doi":"10.1002/HTTPS://DOI.ORG/10.6028/JRES.123.017","DOIUrl":null,"url":null,"abstract":"Data on the calibration fluids water and toluene individually, and the combination of those two sets of data, were correlated with two different equations (resulting in six sets of calibration equation parameters) to analyze data measured with a vibrating-tube densimeter on the lubricants pentaerythritol tetrapentanoate (POE5), pentaerythritol tetraheptanoate (POE7), and pentaerythritol tetranonanoate (POE9) at temperatures from 270 K to 470 K and pressures from 0.5 MPa to 50 MPa. The objective was to explore how the calculated densities of the lubricants would differ based on the calibration equations and calibration fluid(s). The viscosities of the measured lubricants are much greater than those of the calibration fluids, and because there has long been a question of how measurements of higher viscosity fluids are affected when measured with a vibrating-tube densimeter, combinations of calibration fluid(s) and equations were tested to explore the role they play in obtaining accurate results. For the lubricants studied herein, more accurate results were obtained with a calibration fitted to multiple calibration fluids, while the consistency of results was more equation dependent.","PeriodicalId":54766,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":"123 1","pages":"1-10"},"PeriodicalIF":1.3000,"publicationDate":"2018-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Calibration Fluids and Calibration Equations: How Choices May Affect the Results of Density Measurements Made with U-Tube Densimeters.\",\"authors\":\"S. Outcalt\",\"doi\":\"10.1002/HTTPS://DOI.ORG/10.6028/JRES.123.017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Data on the calibration fluids water and toluene individually, and the combination of those two sets of data, were correlated with two different equations (resulting in six sets of calibration equation parameters) to analyze data measured with a vibrating-tube densimeter on the lubricants pentaerythritol tetrapentanoate (POE5), pentaerythritol tetraheptanoate (POE7), and pentaerythritol tetranonanoate (POE9) at temperatures from 270 K to 470 K and pressures from 0.5 MPa to 50 MPa. The objective was to explore how the calculated densities of the lubricants would differ based on the calibration equations and calibration fluid(s). The viscosities of the measured lubricants are much greater than those of the calibration fluids, and because there has long been a question of how measurements of higher viscosity fluids are affected when measured with a vibrating-tube densimeter, combinations of calibration fluid(s) and equations were tested to explore the role they play in obtaining accurate results. For the lubricants studied herein, more accurate results were obtained with a calibration fitted to multiple calibration fluids, while the consistency of results was more equation dependent.\",\"PeriodicalId\":54766,\"journal\":{\"name\":\"Journal of Research of the National Institute of Standards and Technology\",\"volume\":\"123 1\",\"pages\":\"1-10\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2018-10-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Research of the National Institute of Standards and Technology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1002/HTTPS://DOI.ORG/10.6028/JRES.123.017\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Research of the National Institute of Standards and Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1002/HTTPS://DOI.ORG/10.6028/JRES.123.017","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
Calibration Fluids and Calibration Equations: How Choices May Affect the Results of Density Measurements Made with U-Tube Densimeters.
Data on the calibration fluids water and toluene individually, and the combination of those two sets of data, were correlated with two different equations (resulting in six sets of calibration equation parameters) to analyze data measured with a vibrating-tube densimeter on the lubricants pentaerythritol tetrapentanoate (POE5), pentaerythritol tetraheptanoate (POE7), and pentaerythritol tetranonanoate (POE9) at temperatures from 270 K to 470 K and pressures from 0.5 MPa to 50 MPa. The objective was to explore how the calculated densities of the lubricants would differ based on the calibration equations and calibration fluid(s). The viscosities of the measured lubricants are much greater than those of the calibration fluids, and because there has long been a question of how measurements of higher viscosity fluids are affected when measured with a vibrating-tube densimeter, combinations of calibration fluid(s) and equations were tested to explore the role they play in obtaining accurate results. For the lubricants studied herein, more accurate results were obtained with a calibration fitted to multiple calibration fluids, while the consistency of results was more equation dependent.
期刊介绍:
The Journal of Research of the National Institute of Standards and Technology is the flagship publication of the National Institute of Standards and Technology. It has been published under various titles and forms since 1904, with its roots as Scientific Papers issued as the Bulletin of the Bureau of Standards.
In 1928, the Scientific Papers were combined with Technologic Papers, which reported results of investigations of material and methods of testing. This new publication was titled the Bureau of Standards Journal of Research.
The Journal of Research of NIST reports NIST research and development in metrology and related fields of physical science, engineering, applied mathematics, statistics, biotechnology, information technology.