免疫传感器制造方法:范围综述

Fajar Ajinugroho, T. Abuzairi, Siti Fauziyah
{"title":"免疫传感器制造方法:范围综述","authors":"Fajar Ajinugroho, T. Abuzairi, Siti Fauziyah","doi":"10.31101/jhes.2531","DOIUrl":null,"url":null,"abstract":"Various methods of establishing a diagnosis, especially for initial diagnosis, have been widely developed, such as Rapid Diagnostic Test (RDT), Enzyme-linked immunosorbent assay (ELISA), and polymerase chain reaction (PCR). However, those tools have several different limitations in each tool. The limitations of this tool include a fairly high error rate and the need for complex tools. The work can only be used by special personnel and a long processing time. Immunosensors are tools that can be used as an alternative. Immunosensor is a sensor used to detect specific immune reactions between antibodies and targets in the form of antigens and can detect interactions between analyte targets and antibodies from changes in electrochemical signal, sot the examination time is relatively faster. This scoping review aims to review each immunosensor fabrication parameter. The results proved that each analyte has a different characterization and is very diverse. So it is necessary to select the right parameters (electrode type, immunoassay configuration, electrode modification, receptor immobilization, and electrochemical characterization). The linear range and detection limit are also important parameters that can be developed so that very limited analyte concentrations in the sample can be detected. It is necessary to review fabrication methods to improve the stability of immunosensors so that the ligands contained in the immunosensor electrodes can last a long time to be able to carry out mass production.","PeriodicalId":32178,"journal":{"name":"JHeS Journal of Health Studies","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Immunosensor fabrication methods: A scoping review\",\"authors\":\"Fajar Ajinugroho, T. Abuzairi, Siti Fauziyah\",\"doi\":\"10.31101/jhes.2531\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Various methods of establishing a diagnosis, especially for initial diagnosis, have been widely developed, such as Rapid Diagnostic Test (RDT), Enzyme-linked immunosorbent assay (ELISA), and polymerase chain reaction (PCR). However, those tools have several different limitations in each tool. The limitations of this tool include a fairly high error rate and the need for complex tools. The work can only be used by special personnel and a long processing time. Immunosensors are tools that can be used as an alternative. Immunosensor is a sensor used to detect specific immune reactions between antibodies and targets in the form of antigens and can detect interactions between analyte targets and antibodies from changes in electrochemical signal, sot the examination time is relatively faster. This scoping review aims to review each immunosensor fabrication parameter. The results proved that each analyte has a different characterization and is very diverse. So it is necessary to select the right parameters (electrode type, immunoassay configuration, electrode modification, receptor immobilization, and electrochemical characterization). The linear range and detection limit are also important parameters that can be developed so that very limited analyte concentrations in the sample can be detected. It is necessary to review fabrication methods to improve the stability of immunosensors so that the ligands contained in the immunosensor electrodes can last a long time to be able to carry out mass production.\",\"PeriodicalId\":32178,\"journal\":{\"name\":\"JHeS Journal of Health Studies\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JHeS Journal of Health Studies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31101/jhes.2531\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JHeS Journal of Health Studies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31101/jhes.2531","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

建立诊断的各种方法,特别是用于初步诊断的方法,已经被广泛开发,如快速诊断测试(RDT)、酶联免疫吸附测定(ELISA)和聚合酶链式反应(PCR)。然而,这些工具在每个工具中都有几个不同的限制。该工具的局限性包括相当高的错误率和对复杂工具的需求。该工作只能由专人使用,处理时间长。免疫传感器是一种可以作为替代品使用的工具。免疫传感器是一种用于检测抗原形式的抗体和靶标之间的特异性免疫反应的传感器,可以通过电化学信号的变化来检测分析物靶标和抗体之间的相互作用,因此检查时间相对较快。本范围审查旨在审查每个免疫传感器的制造参数。结果证明,每种分析物都有不同的特征,并且非常多样化。因此,有必要选择正确的参数(电极类型、免疫测定配置、电极修饰、受体固定化和电化学表征)。线性范围和检测极限也是可以开发的重要参数,从而可以检测样品中非常有限的分析物浓度。有必要回顾提高免疫传感器稳定性的制造方法,以便免疫传感器电极中包含的配体能够持续很长时间,从而能够进行大规模生产。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Immunosensor fabrication methods: A scoping review
Various methods of establishing a diagnosis, especially for initial diagnosis, have been widely developed, such as Rapid Diagnostic Test (RDT), Enzyme-linked immunosorbent assay (ELISA), and polymerase chain reaction (PCR). However, those tools have several different limitations in each tool. The limitations of this tool include a fairly high error rate and the need for complex tools. The work can only be used by special personnel and a long processing time. Immunosensors are tools that can be used as an alternative. Immunosensor is a sensor used to detect specific immune reactions between antibodies and targets in the form of antigens and can detect interactions between analyte targets and antibodies from changes in electrochemical signal, sot the examination time is relatively faster. This scoping review aims to review each immunosensor fabrication parameter. The results proved that each analyte has a different characterization and is very diverse. So it is necessary to select the right parameters (electrode type, immunoassay configuration, electrode modification, receptor immobilization, and electrochemical characterization). The linear range and detection limit are also important parameters that can be developed so that very limited analyte concentrations in the sample can be detected. It is necessary to review fabrication methods to improve the stability of immunosensors so that the ligands contained in the immunosensor electrodes can last a long time to be able to carry out mass production.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
10
审稿时长
12 weeks
期刊最新文献
Immunosensor fabrication methods: A scoping review The use of five-finger relaxation techniques for reducing stress and sleep quality in hypertension patients Overview of malaria prevention and treatment management in The Gambia: a descriptive study Factors Affecting Quality of Life in Chronic Kidney Failure Patients Receiving Hemodialysis Interventions strategy reducing postpartum fatigue: a literature review
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1