IF 0.9 Q4 CONSTRUCTION & BUILDING TECHNOLOGY Journal of Structural Fire Engineering Pub Date : 2021-08-13 DOI:10.1108/jsfe-02-2021-0009
P. Piloto, Carlos Balsa, Felipe Macedo Macêdo Gomes, Bergson Matias
{"title":"天然火灾下钢层板组合楼板的耐火性能","authors":"P. Piloto, Carlos Balsa, Felipe Macedo Macêdo Gomes, Bergson Matias","doi":"10.1108/jsfe-02-2021-0009","DOIUrl":null,"url":null,"abstract":"PurposeMost of the numerical research and experiments on composite slabs with a steel deck have been developed to study the effect of fire during the heating phase. This manuscript aims to describe the thermal behaviour of composite slabs when submitted to different fire scenarios, considering the heating and cooling phase.Design/methodology/approachThree-dimensional numerical models, based on finite elements, are developed to analyse the temperatures inside the composite slab and, consequently, to estimate the fire resistance, considering the insulation criteria (I). The numerical methods developed are validated with experimental results available in the literature. In addition, this paper presents a parametric study of the effects on fire resistance caused by the thickness of the concrete part of the slab as well as the natural fire scenario.FindingsThe results show that, depending on the fire scenario, the fire resistance criterion can be reached during the cooling phase, especially for the thickest composite slabs. Based on the results, new coefficients are proposed for the original simplified model, proposed by the standard.Originality/valueThe developed numerical models allow us to realistically simulate the thermal effects caused by a natural fire in a composite slab and the new proposal enables us to estimate the fire resistance time of composite slabs with a steel deck, even if it occurs in the cooling phase.","PeriodicalId":45033,"journal":{"name":"Journal of Structural Fire Engineering","volume":" ","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2021-08-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fire resistance of composite slabs with steel deck under natural fire\",\"authors\":\"P. Piloto, Carlos Balsa, Felipe Macedo Macêdo Gomes, Bergson Matias\",\"doi\":\"10.1108/jsfe-02-2021-0009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"PurposeMost of the numerical research and experiments on composite slabs with a steel deck have been developed to study the effect of fire during the heating phase. This manuscript aims to describe the thermal behaviour of composite slabs when submitted to different fire scenarios, considering the heating and cooling phase.Design/methodology/approachThree-dimensional numerical models, based on finite elements, are developed to analyse the temperatures inside the composite slab and, consequently, to estimate the fire resistance, considering the insulation criteria (I). The numerical methods developed are validated with experimental results available in the literature. In addition, this paper presents a parametric study of the effects on fire resistance caused by the thickness of the concrete part of the slab as well as the natural fire scenario.FindingsThe results show that, depending on the fire scenario, the fire resistance criterion can be reached during the cooling phase, especially for the thickest composite slabs. Based on the results, new coefficients are proposed for the original simplified model, proposed by the standard.Originality/valueThe developed numerical models allow us to realistically simulate the thermal effects caused by a natural fire in a composite slab and the new proposal enables us to estimate the fire resistance time of composite slabs with a steel deck, even if it occurs in the cooling phase.\",\"PeriodicalId\":45033,\"journal\":{\"name\":\"Journal of Structural Fire Engineering\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2021-08-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Structural Fire Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1108/jsfe-02-2021-0009\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Structural Fire Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1108/jsfe-02-2021-0009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的对钢层板复合材料板进行了大量的数值研究和实验,以研究加热阶段火灾的影响。本文旨在描述考虑加热和冷却阶段的复合材料板在不同火灾场景下的热行为。设计/方法/方法基于有限元的三维数值模型被开发用于分析复合板内部的温度,从而在考虑绝缘标准(I)的情况下估计耐火性。所开发的数值方法与文献中的实验结果进行了验证。此外,本文还对楼板混凝土部分的厚度以及自然火灾情况对耐火性能的影响进行了参数研究。结果表明,根据火灾情况,在冷却阶段可以达到耐火标准,尤其是对于最厚的复合板。基于结果,对标准提出的原始简化模型提出了新的系数。独创性/价值所开发的数值模型使我们能够真实地模拟复合板中自然火灾引起的热效应,而新的提案使我们能够估计具有钢甲板的复合板的耐火时间,即使它发生在冷却阶段。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fire resistance of composite slabs with steel deck under natural fire
PurposeMost of the numerical research and experiments on composite slabs with a steel deck have been developed to study the effect of fire during the heating phase. This manuscript aims to describe the thermal behaviour of composite slabs when submitted to different fire scenarios, considering the heating and cooling phase.Design/methodology/approachThree-dimensional numerical models, based on finite elements, are developed to analyse the temperatures inside the composite slab and, consequently, to estimate the fire resistance, considering the insulation criteria (I). The numerical methods developed are validated with experimental results available in the literature. In addition, this paper presents a parametric study of the effects on fire resistance caused by the thickness of the concrete part of the slab as well as the natural fire scenario.FindingsThe results show that, depending on the fire scenario, the fire resistance criterion can be reached during the cooling phase, especially for the thickest composite slabs. Based on the results, new coefficients are proposed for the original simplified model, proposed by the standard.Originality/valueThe developed numerical models allow us to realistically simulate the thermal effects caused by a natural fire in a composite slab and the new proposal enables us to estimate the fire resistance time of composite slabs with a steel deck, even if it occurs in the cooling phase.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Structural Fire Engineering
Journal of Structural Fire Engineering CONSTRUCTION & BUILDING TECHNOLOGY-
CiteScore
2.20
自引率
10.00%
发文量
28
期刊最新文献
Post-fire response of S235 steel plates considering different bolt hole-making processes Investigation on performance of prestressed hollow core slabs exposed to elevated temperatures Post-fire behavior of geopolymer concrete with sodium silicate waste as an alternative to conventional river sand Effect of the elevated temperature on the mechanical properties of geopolymer concrete using fly ash and ground granulated blast slag Assessment of critical parameters affecting the behaviour of bearing reinforced concrete walls under fire exposure
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1