修正背景和密度对碘化钠探测器测定伽马辐射体影响的建议

A. M. Velásquez, Fernando Mosos, Giovanni Vela
{"title":"修正背景和密度对碘化钠探测器测定伽马辐射体影响的建议","authors":"A. M. Velásquez, Fernando Mosos, Giovanni Vela","doi":"10.32685/2590-7468/invapnuclear.5.2021.593","DOIUrl":null,"url":null,"abstract":"This study develops a modification to the spectra decomposition method for sodium iodide scintillation equipment, including correcting the natural background counts for the activity concentration calculation. A comparison of the results obtained between two sodium iodide detectors of 2 X 2 in and 3 x 3 in versus a hyper-pure germanium detector of 50 % relative efficiency is performed for soil, sediment, and water samples. It is found that background correction significantly improves activity concentration results in higher energy regions. The concentration values determined by the different spectrometric systems for the samples analyzed do not show significant differences, which supports the results obtained with the proposed calculation method. The uncertainty associated with the measurement and detection limits for the NaI (Tl) detectors is higher than those obtained with the GeHp detector due to the operation of the two technologies and the presence of interferences in the regions of interest. The study carried out in this work establishes an analytical milestone. The methodological model proposed makes it possible to quantify, with reliable results, low concentration levels of NORM materials and even 131I using sodium iodide detectors, among other analytical applications of general interest.","PeriodicalId":33998,"journal":{"name":"Revista Investigaciones y Aplicaciones Nucleares","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Proposal to correct for the effect of background and density in the determination of gamma emitters using sodium iodide detectors\",\"authors\":\"A. M. Velásquez, Fernando Mosos, Giovanni Vela\",\"doi\":\"10.32685/2590-7468/invapnuclear.5.2021.593\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study develops a modification to the spectra decomposition method for sodium iodide scintillation equipment, including correcting the natural background counts for the activity concentration calculation. A comparison of the results obtained between two sodium iodide detectors of 2 X 2 in and 3 x 3 in versus a hyper-pure germanium detector of 50 % relative efficiency is performed for soil, sediment, and water samples. It is found that background correction significantly improves activity concentration results in higher energy regions. The concentration values determined by the different spectrometric systems for the samples analyzed do not show significant differences, which supports the results obtained with the proposed calculation method. The uncertainty associated with the measurement and detection limits for the NaI (Tl) detectors is higher than those obtained with the GeHp detector due to the operation of the two technologies and the presence of interferences in the regions of interest. The study carried out in this work establishes an analytical milestone. The methodological model proposed makes it possible to quantify, with reliable results, low concentration levels of NORM materials and even 131I using sodium iodide detectors, among other analytical applications of general interest.\",\"PeriodicalId\":33998,\"journal\":{\"name\":\"Revista Investigaciones y Aplicaciones Nucleares\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Investigaciones y Aplicaciones Nucleares\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.32685/2590-7468/invapnuclear.5.2021.593\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Investigaciones y Aplicaciones Nucleares","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32685/2590-7468/invapnuclear.5.2021.593","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文对碘化钠闪烁设备的光谱分解方法进行了改进,包括修正了活度浓度计算中的自然本底计数。比较了2 × 2英寸和3 × 3英寸的两种碘化钠探测器与50%相对效率的超纯锗探测器之间的结果,对土壤、沉积物和水样进行了比较。研究发现,背景校正显著改善了高能量区域的活动浓度结果。不同光谱系统测定的样品的浓度值没有显著差异,这支持了所提出的计算方法得到的结果。与NaI (Tl)探测器的测量和检测限相关的不确定度高于用GeHp探测器获得的不确定度,这是由于两种技术的操作以及感兴趣区域存在干扰。在这项工作中进行的研究建立了一个分析里程碑。所提出的方法模型使使用碘化钠探测器对低浓度的NORM材料甚至131I进行量化并获得可靠的结果成为可能,以及其他普遍感兴趣的分析应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Proposal to correct for the effect of background and density in the determination of gamma emitters using sodium iodide detectors
This study develops a modification to the spectra decomposition method for sodium iodide scintillation equipment, including correcting the natural background counts for the activity concentration calculation. A comparison of the results obtained between two sodium iodide detectors of 2 X 2 in and 3 x 3 in versus a hyper-pure germanium detector of 50 % relative efficiency is performed for soil, sediment, and water samples. It is found that background correction significantly improves activity concentration results in higher energy regions. The concentration values determined by the different spectrometric systems for the samples analyzed do not show significant differences, which supports the results obtained with the proposed calculation method. The uncertainty associated with the measurement and detection limits for the NaI (Tl) detectors is higher than those obtained with the GeHp detector due to the operation of the two technologies and the presence of interferences in the regions of interest. The study carried out in this work establishes an analytical milestone. The methodological model proposed makes it possible to quantify, with reliable results, low concentration levels of NORM materials and even 131I using sodium iodide detectors, among other analytical applications of general interest.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
9
审稿时长
24 weeks
期刊最新文献
Visualización interactiva de las importaciones de materiales radiactivos en Colombia de 2012 a 2022 Estimation of radioactive activity by gamma spectroscopy Intercomparación de las dosis obtenidas con el sistema Fricke y en el Laboratorio Secundario de Calibración Dosimétrica Estudio preliminar de la aplicación de la técnica VMAT en irradiación corporal total: diseño de una camilla rotable Efecto del kV en la calidad de imagen y la dosis de radiación en exámenes pediátricos de tomografía computarizada de cráneo simple del Hospital Universitario Clínica San Rafael
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1