麻醉前坐位测量的体积变异性指数可以预测剖宫产术中脊柱麻醉引起的低血压:一项观察性研究

Erhan Ozyurt
{"title":"麻醉前坐位测量的体积变异性指数可以预测剖宫产术中脊柱麻醉引起的低血压:一项观察性研究","authors":"Erhan Ozyurt","doi":"10.4103/joacc.joacc_97_21","DOIUrl":null,"url":null,"abstract":"Background: Hypotension induced by spinal anaesthesia during caesarean section can have devastating effects on the parturient and foetus. This study investigated the ability to predict spinal anaesthesia-induced hypotension via the perfusion index and pleth variability index in the sitting position caesarean section. Materials and Methods: We enrolled 46 patients undergoing elective caesarean section in this study and used standard anaesthetic management in all patients. The haemodynamic parameters, perfusion index and pleth variability index of the patients were recorded at specific time points. Results: Hypotension occurred in 61.4% of the patients. There was a difference in the pleth variability index values between patients with and without hypotension at baseline as well as in the sitting position and after spinal anaesthesia (P = 0.023, 0.001, and 0.040, respectively). According to the receiver operating characteristic curve analysis, the pleth variability index value of the patients in the sitting position was a predictor of spinal anaesthesia-induced hypotension (area under the curve = 0.780, 95% confidence interval [CI]: 0.633–0.927, P = 0.001). The cut-off value of the pleth variability index (in the sitting position) for predicting hypotension was 20.5% (sensitivity: 76.5%, specificity: 70.4%). Multivariate logistic regression analysis revealed that an increased pleth variability index in the sitting position before spinal anaesthesia was an independent risk factor of spinal anaesthesia-induced hypotension (odds ratio: 0.78, 95% CI: 0.62–0.98, P = 0.034). Conclusion: The pleth variability index in the sitting position before spinal anaesthesia is a useful tool for predicting spinal anaesthesia-induced hypotension during caesarean section.","PeriodicalId":16611,"journal":{"name":"Journal of Obstetric Anaesthesia and Critical Care","volume":null,"pages":null},"PeriodicalIF":0.2000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Pleth variability index measured in the sitting position before anesthesia can predict spinal anesthesia-induced hypotension in cesarean section: An observational study\",\"authors\":\"Erhan Ozyurt\",\"doi\":\"10.4103/joacc.joacc_97_21\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Hypotension induced by spinal anaesthesia during caesarean section can have devastating effects on the parturient and foetus. This study investigated the ability to predict spinal anaesthesia-induced hypotension via the perfusion index and pleth variability index in the sitting position caesarean section. Materials and Methods: We enrolled 46 patients undergoing elective caesarean section in this study and used standard anaesthetic management in all patients. The haemodynamic parameters, perfusion index and pleth variability index of the patients were recorded at specific time points. Results: Hypotension occurred in 61.4% of the patients. There was a difference in the pleth variability index values between patients with and without hypotension at baseline as well as in the sitting position and after spinal anaesthesia (P = 0.023, 0.001, and 0.040, respectively). According to the receiver operating characteristic curve analysis, the pleth variability index value of the patients in the sitting position was a predictor of spinal anaesthesia-induced hypotension (area under the curve = 0.780, 95% confidence interval [CI]: 0.633–0.927, P = 0.001). The cut-off value of the pleth variability index (in the sitting position) for predicting hypotension was 20.5% (sensitivity: 76.5%, specificity: 70.4%). Multivariate logistic regression analysis revealed that an increased pleth variability index in the sitting position before spinal anaesthesia was an independent risk factor of spinal anaesthesia-induced hypotension (odds ratio: 0.78, 95% CI: 0.62–0.98, P = 0.034). Conclusion: The pleth variability index in the sitting position before spinal anaesthesia is a useful tool for predicting spinal anaesthesia-induced hypotension during caesarean section.\",\"PeriodicalId\":16611,\"journal\":{\"name\":\"Journal of Obstetric Anaesthesia and Critical Care\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Obstetric Anaesthesia and Critical Care\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/joacc.joacc_97_21\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Obstetric Anaesthesia and Critical Care","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/joacc.joacc_97_21","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 1

摘要

背景:剖宫产过程中脊髓麻醉引起的低血压会对产妇和胎儿产生毁灭性影响。本研究通过坐位剖宫产术中的灌注指数和体积变异指数来预测脊髓麻醉诱导的低血压的能力。材料和方法:我们在本研究中招募了46名接受选择性剖腹产的患者,并对所有患者使用标准的麻醉管理。在特定时间点记录患者的血液动力学参数、灌注指数和体积变异指数。结果:61.4%的患者出现低血压。基线时有低血压和无低血压的患者之间以及坐姿和脊柱麻醉后的患者之间的体积变异指数值存在差异(分别为P=0.023、0.001和0.040)。根据接收机工作特性曲线分析,坐姿患者的体积变异性指数值是脊髓麻醉引起低血压的预测指标(曲线下面积=0.780,95%置信区间[CI]:0.633-0.927,P=0.001)。体积变异性指标(坐姿)预测低血压的临界值为20.5%(敏感性:76.5%,特异性:70.4%)回归分析表明,腰麻前坐姿的体积变异指数增加是腰麻引起低血压的独立危险因素(比值比:0.78,95%CI:0.62–0.98,P=0.034)。结论:腰麻前坐位体积变异指数是预测腰麻引起的低血压的有用工具剖腹产时低血压。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Pleth variability index measured in the sitting position before anesthesia can predict spinal anesthesia-induced hypotension in cesarean section: An observational study
Background: Hypotension induced by spinal anaesthesia during caesarean section can have devastating effects on the parturient and foetus. This study investigated the ability to predict spinal anaesthesia-induced hypotension via the perfusion index and pleth variability index in the sitting position caesarean section. Materials and Methods: We enrolled 46 patients undergoing elective caesarean section in this study and used standard anaesthetic management in all patients. The haemodynamic parameters, perfusion index and pleth variability index of the patients were recorded at specific time points. Results: Hypotension occurred in 61.4% of the patients. There was a difference in the pleth variability index values between patients with and without hypotension at baseline as well as in the sitting position and after spinal anaesthesia (P = 0.023, 0.001, and 0.040, respectively). According to the receiver operating characteristic curve analysis, the pleth variability index value of the patients in the sitting position was a predictor of spinal anaesthesia-induced hypotension (area under the curve = 0.780, 95% confidence interval [CI]: 0.633–0.927, P = 0.001). The cut-off value of the pleth variability index (in the sitting position) for predicting hypotension was 20.5% (sensitivity: 76.5%, specificity: 70.4%). Multivariate logistic regression analysis revealed that an increased pleth variability index in the sitting position before spinal anaesthesia was an independent risk factor of spinal anaesthesia-induced hypotension (odds ratio: 0.78, 95% CI: 0.62–0.98, P = 0.034). Conclusion: The pleth variability index in the sitting position before spinal anaesthesia is a useful tool for predicting spinal anaesthesia-induced hypotension during caesarean section.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
37
审稿时长
29 weeks
期刊最新文献
To study maternal hypotension, side-effects and fetal acid-base balance during cesarean delivery under spinal anesthesia using prophylactic infusion doses of 25 and 50 μg/Min phenylephrine Takotsubo cardiomyopathy in pregnancy: A focused review Comparative evaluation of two doses of phenylephrine infusion to prevent intra-operative nausea and vomiting during elective obstetric spinal anesthesia Carbetocin: Are we ready for a paradigm shift? Evaluation of perfusion index as a screening tool for prediction of hypotension and shivering in cesarean section
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1