{"title":"抗旋转铆钉接触界面的超声检测研究","authors":"C. Yao, Hsueh Chih Cheng","doi":"10.20855/ijav.2019.24.41330","DOIUrl":null,"url":null,"abstract":"This work measures the contact area between an anti-rotation rivet and an aluminum plate under different riveting loads based on the regional scanning of ultrasound. The contact image is a novel disclosure for the anti-rotation rivet contact. The 2D maps show an apparent change not only in area sizes but also in contact shapes under various normal forces applied. The 3D contact images also provide useful information to show the intensity of contact. The contact area between the anti-rotation rivet and the aluminum is calculated using an image analysis software package. The range of contact areas varies from 6.3 mm to 57.2 mm, depending on the applied forces and the definition of the contrast ratio. Furthermore, a calibration of data fitting is performed to provide a useful polynomial equation for contact area estimation. In addition, maps of both a reflection coefficient and a pressure contour distribution are presented. The range of peak contact pressure varies from 7.1 MPa to 11.2 MPa.","PeriodicalId":49185,"journal":{"name":"International Journal of Acoustics and Vibration","volume":"24 1","pages":"648-656"},"PeriodicalIF":0.8000,"publicationDate":"2019-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Study of Contact Interface for an Anti-Rotation Rivet Using Ultrasonic Detection\",\"authors\":\"C. Yao, Hsueh Chih Cheng\",\"doi\":\"10.20855/ijav.2019.24.41330\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work measures the contact area between an anti-rotation rivet and an aluminum plate under different riveting loads based on the regional scanning of ultrasound. The contact image is a novel disclosure for the anti-rotation rivet contact. The 2D maps show an apparent change not only in area sizes but also in contact shapes under various normal forces applied. The 3D contact images also provide useful information to show the intensity of contact. The contact area between the anti-rotation rivet and the aluminum is calculated using an image analysis software package. The range of contact areas varies from 6.3 mm to 57.2 mm, depending on the applied forces and the definition of the contrast ratio. Furthermore, a calibration of data fitting is performed to provide a useful polynomial equation for contact area estimation. In addition, maps of both a reflection coefficient and a pressure contour distribution are presented. The range of peak contact pressure varies from 7.1 MPa to 11.2 MPa.\",\"PeriodicalId\":49185,\"journal\":{\"name\":\"International Journal of Acoustics and Vibration\",\"volume\":\"24 1\",\"pages\":\"648-656\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2019-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Acoustics and Vibration\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.20855/ijav.2019.24.41330\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Acoustics and Vibration","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.20855/ijav.2019.24.41330","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ACOUSTICS","Score":null,"Total":0}
A Study of Contact Interface for an Anti-Rotation Rivet Using Ultrasonic Detection
This work measures the contact area between an anti-rotation rivet and an aluminum plate under different riveting loads based on the regional scanning of ultrasound. The contact image is a novel disclosure for the anti-rotation rivet contact. The 2D maps show an apparent change not only in area sizes but also in contact shapes under various normal forces applied. The 3D contact images also provide useful information to show the intensity of contact. The contact area between the anti-rotation rivet and the aluminum is calculated using an image analysis software package. The range of contact areas varies from 6.3 mm to 57.2 mm, depending on the applied forces and the definition of the contrast ratio. Furthermore, a calibration of data fitting is performed to provide a useful polynomial equation for contact area estimation. In addition, maps of both a reflection coefficient and a pressure contour distribution are presented. The range of peak contact pressure varies from 7.1 MPa to 11.2 MPa.
期刊介绍:
The International Journal of Acoustics and Vibration (IJAV) is the refereed open-access journal of the International Institute of Acoustics and Vibration (IIAV). The IIAV is a non-profit international scientific society founded in 1995. The primary objective of the Institute is to advance the science of acoustics and vibration by creating an international organization that is responsive to the needs of scientists and engineers concerned with acoustics and vibration problems all around the world.
Manuscripts of articles, technical notes and letters-to-the-editor should be submitted to the Editor-in-Chief via the on-line submission system. Authors wishing to submit an article need to log in on the IJAV website first. Users logged into the website are able to submit new articles, track the status of their articles already submitted, upload revised articles, responses and/or rebuttals to reviewers, figures, biographies, photographs, copyright transfer agreements, and send comments to the editor. Each time the status of an article submitted changes, the author will also be notified automatically by email.
IIAV members (in good standing for at least six months) can publish in IJAV free of charge and their papers will be displayed on-line immediately after they have been edited and laid-out.
Non-IIAV members will be required to pay a mandatory Article Processing Charge (APC) of $200 USD if the manuscript is accepted for publication after review. The APC fee allows IIAV to make your research freely available to all readers using the Open Access model.
In addition, Non-IIAV members who pay an extra voluntary publication fee (EVPF) of $500 USD will be granted expedited publication in the IJAV Journal and their papers can be displayed on the Internet after acceptance. If the $200 USD (APC) publication fee is not honored, papers will not be published. Authors who do not pay the voluntary fixed fee of $500 USD will have their papers published but there may be a considerable delay.
The English text of the papers must be of high quality. If the text submitted is of low quality the manuscript will be more than likely rejected. For authors whose first language is not English, we recommend having their manuscripts reviewed and edited prior to submission by a native English speaker with scientific expertise. There are many commercial editing services which can provide this service at a cost to the authors.