HVOF沉积Zn-Ni-Cu和Zn-Ni-Cu - tib2涂层在低碳钢上的腐蚀行为

IF 2.7 4区 材料科学 Q3 ELECTROCHEMISTRY Corrosion Reviews Pub Date : 2022-08-25 DOI:10.1515/corrrev-2021-0082
Sheikh Idrees Ali, S. N. Ahmad
{"title":"HVOF沉积Zn-Ni-Cu和Zn-Ni-Cu - tib2涂层在低碳钢上的腐蚀行为","authors":"Sheikh Idrees Ali, S. N. Ahmad","doi":"10.1515/corrrev-2021-0082","DOIUrl":null,"url":null,"abstract":"Abstract In this study, Zn–Ni–Cu and Zn–Ni–Cu–TiB2 coatings were deposited using high-velocity oxy-fuel (HVOF) thermal spray technique on a mild steel substrate. Corrosion tests like neutral salt spray (NSS) following (ASTM B-117) standard and immersion cycle test following ASTM G-31, ASTM G1-03, standards were carried out for Zn–Ni–Cu and Zn–Ni–Cu–TiB2 coated mild steel along with uncoated mild steel acting as a control. Both Zn–Ni–Cu and Zn–Ni–Cu–TiB2 coated mild steel were corrosion resistant as compared to uncoated mild steel. Raman analysis following the immersion cycle test inferred that uncoated mild steel had all forms of rust. While Zn–Ni–Cu and Zn–Ni–Cu–TiB2 coated mild steel developed very little rust. The characterization helped to understand the changes in the surface before and after tests. It was observed that both Zn–Ni–Cu and Zn–Ni–Cu–TiB2 coated mild steel had little corrosion degradation of surface as compared to uncoated mild steel. Suggesting that both coatings performed significantly better compared to uncoated mild steel in corrosive environments. Polarization and EIS tests of both coated and uncoated mild steel in a 3.5% NaCl medium helped to understand the behaviour of coatings over a range of frequencies. Both coated samples had high polarization potential Ecorr values and lower polarization current Icorr values as compared to uncoated mild steel. Inferring better performance of coatings in corrosive environments as compared to uncoated mild steel.","PeriodicalId":10721,"journal":{"name":"Corrosion Reviews","volume":"40 1","pages":"611 - 624"},"PeriodicalIF":2.7000,"publicationDate":"2022-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Corrosion behaviour OF HVOF deposited Zn–Ni–Cu and Zn–Ni–Cu–TiB2 coatings on mild steel\",\"authors\":\"Sheikh Idrees Ali, S. N. Ahmad\",\"doi\":\"10.1515/corrrev-2021-0082\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract In this study, Zn–Ni–Cu and Zn–Ni–Cu–TiB2 coatings were deposited using high-velocity oxy-fuel (HVOF) thermal spray technique on a mild steel substrate. Corrosion tests like neutral salt spray (NSS) following (ASTM B-117) standard and immersion cycle test following ASTM G-31, ASTM G1-03, standards were carried out for Zn–Ni–Cu and Zn–Ni–Cu–TiB2 coated mild steel along with uncoated mild steel acting as a control. Both Zn–Ni–Cu and Zn–Ni–Cu–TiB2 coated mild steel were corrosion resistant as compared to uncoated mild steel. Raman analysis following the immersion cycle test inferred that uncoated mild steel had all forms of rust. While Zn–Ni–Cu and Zn–Ni–Cu–TiB2 coated mild steel developed very little rust. The characterization helped to understand the changes in the surface before and after tests. It was observed that both Zn–Ni–Cu and Zn–Ni–Cu–TiB2 coated mild steel had little corrosion degradation of surface as compared to uncoated mild steel. Suggesting that both coatings performed significantly better compared to uncoated mild steel in corrosive environments. Polarization and EIS tests of both coated and uncoated mild steel in a 3.5% NaCl medium helped to understand the behaviour of coatings over a range of frequencies. Both coated samples had high polarization potential Ecorr values and lower polarization current Icorr values as compared to uncoated mild steel. Inferring better performance of coatings in corrosive environments as compared to uncoated mild steel.\",\"PeriodicalId\":10721,\"journal\":{\"name\":\"Corrosion Reviews\",\"volume\":\"40 1\",\"pages\":\"611 - 624\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2022-08-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Corrosion Reviews\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.1515/corrrev-2021-0082\",\"RegionNum\":4,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ELECTROCHEMISTRY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Corrosion Reviews","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1515/corrrev-2021-0082","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
引用次数: 3

摘要

摘要本研究采用高速氧燃料(HVOF)热喷涂技术在低碳钢基体上沉积Zn-Ni-Cu和Zn-Ni-Cu - tib2涂层。按照(ASTM B-117)标准进行的中性盐雾(NSS)腐蚀试验和按照ASTM G-31、ASTM G1-03标准进行的浸泡循环试验对镀Zn-Ni-Cu和镀Zn-Ni-Cu - tib2的低碳钢以及作为对照的未镀Zn-Ni-Cu的低碳钢进行了腐蚀试验。Zn-Ni-Cu和Zn-Ni-Cu - tib2涂层低碳钢都比未涂层的低碳钢耐腐蚀。浸没循环试验后的拉曼分析推断,未涂覆的低碳钢有各种形式的锈蚀。而Zn-Ni-Cu和Zn-Ni-Cu - tib2涂层的低碳钢几乎没有生锈。表征有助于了解测试前后表面的变化。结果表明:镀Zn-Ni-Cu和镀Zn-Ni-Cu - tib2涂层的低碳钢与未镀Zn-Ni-Cu - tib2涂层的低碳钢相比,表面腐蚀退化较小;这表明两种涂层在腐蚀性环境下的性能都明显优于未涂层的低碳钢。在3.5% NaCl介质中对涂层和未涂层的低碳钢进行极化和EIS测试,有助于了解涂层在频率范围内的行为。与未涂覆的低碳钢相比,两种涂层样品均具有较高的极化电位Ecorr值和较低的极化电流Icorr值。与未涂覆的低碳钢相比,涂层在腐蚀性环境中的性能更好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Corrosion behaviour OF HVOF deposited Zn–Ni–Cu and Zn–Ni–Cu–TiB2 coatings on mild steel
Abstract In this study, Zn–Ni–Cu and Zn–Ni–Cu–TiB2 coatings were deposited using high-velocity oxy-fuel (HVOF) thermal spray technique on a mild steel substrate. Corrosion tests like neutral salt spray (NSS) following (ASTM B-117) standard and immersion cycle test following ASTM G-31, ASTM G1-03, standards were carried out for Zn–Ni–Cu and Zn–Ni–Cu–TiB2 coated mild steel along with uncoated mild steel acting as a control. Both Zn–Ni–Cu and Zn–Ni–Cu–TiB2 coated mild steel were corrosion resistant as compared to uncoated mild steel. Raman analysis following the immersion cycle test inferred that uncoated mild steel had all forms of rust. While Zn–Ni–Cu and Zn–Ni–Cu–TiB2 coated mild steel developed very little rust. The characterization helped to understand the changes in the surface before and after tests. It was observed that both Zn–Ni–Cu and Zn–Ni–Cu–TiB2 coated mild steel had little corrosion degradation of surface as compared to uncoated mild steel. Suggesting that both coatings performed significantly better compared to uncoated mild steel in corrosive environments. Polarization and EIS tests of both coated and uncoated mild steel in a 3.5% NaCl medium helped to understand the behaviour of coatings over a range of frequencies. Both coated samples had high polarization potential Ecorr values and lower polarization current Icorr values as compared to uncoated mild steel. Inferring better performance of coatings in corrosive environments as compared to uncoated mild steel.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Corrosion Reviews
Corrosion Reviews 工程技术-材料科学:膜
CiteScore
5.20
自引率
3.10%
发文量
44
审稿时长
4.5 months
期刊介绍: Corrosion Reviews is an international bimonthly journal devoted to critical reviews and, to a lesser extent, outstanding original articles that are key to advancing the understanding and application of corrosion science and engineering in the service of society. Papers may be of a theoretical, experimental or practical nature, provided that they make a significant contribution to knowledge in the field.
期刊最新文献
Microstructural characteristics of different heat-affected zones in welded joints of UNS S32304 duplex stainless steel using the GMAW process: analysis of the pitting corrosion resistance Corrosion of stainless steels and corrosion protection strategies in the semiconductor manufacturing industry: a review Concrete corrosion in nuclear power plants and other nuclear installations and its mitigation techniques: a review Reviewer acknowledgement Corrosion Reviews volume 41 (2023) Electro-chemo-mechanical properties of anodic oxide (passive) films formed on Cu, Ni and Fe
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1