非血液接触式机械循环支持设备及临床需求综述

IF 2.2 Q2 ENGINEERING, MULTIDISCIPLINARY Applications in engineering science Pub Date : 2022-12-01 DOI:10.1016/j.apples.2022.100122
Shannon N. Ingram , Melanie P. Hager , Michael R. Moreno , John C. Criscione
{"title":"非血液接触式机械循环支持设备及临床需求综述","authors":"Shannon N. Ingram ,&nbsp;Melanie P. Hager ,&nbsp;Michael R. Moreno ,&nbsp;John C. Criscione","doi":"10.1016/j.apples.2022.100122","DOIUrl":null,"url":null,"abstract":"<div><p>LVADs have been in clinical use for a half-century and have advanced through at least 3 generations resulting in compact, durable, and powerful pumps that can deliver blood flow that exceeds the needs of the body at rest. In so doing, these devices have become the best alternative to transplant for patients with end-stage heart failure. That said, the blood contacting interface of these pumps is likely the cause of complications and contraindications that persist with successive generations. Patients with elevated risk for side effects or patients with biventricular failure and other conditions represent the 25% of patients that are not candidates for LVAD therapy. Such patients represent the clinical need for non-blood contacting mechanical circulatory support. The clinical use of direct cardiac compression devices is limited, and there are no devices available for human use. Technological challenges remain, yet these devices continue to be developed and tested in animal models of heart failure.</p></div>","PeriodicalId":72251,"journal":{"name":"Applications in engineering science","volume":"12 ","pages":"Article 100122"},"PeriodicalIF":2.2000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666496822000383/pdfft?md5=c1e3155cc2330b935b9fcb96b6d4907f&pid=1-s2.0-S2666496822000383-main.pdf","citationCount":"1","resultStr":"{\"title\":\"Review of devices and clinical need for non-blood contacting mechanical circulatory support\",\"authors\":\"Shannon N. Ingram ,&nbsp;Melanie P. Hager ,&nbsp;Michael R. Moreno ,&nbsp;John C. Criscione\",\"doi\":\"10.1016/j.apples.2022.100122\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>LVADs have been in clinical use for a half-century and have advanced through at least 3 generations resulting in compact, durable, and powerful pumps that can deliver blood flow that exceeds the needs of the body at rest. In so doing, these devices have become the best alternative to transplant for patients with end-stage heart failure. That said, the blood contacting interface of these pumps is likely the cause of complications and contraindications that persist with successive generations. Patients with elevated risk for side effects or patients with biventricular failure and other conditions represent the 25% of patients that are not candidates for LVAD therapy. Such patients represent the clinical need for non-blood contacting mechanical circulatory support. The clinical use of direct cardiac compression devices is limited, and there are no devices available for human use. Technological challenges remain, yet these devices continue to be developed and tested in animal models of heart failure.</p></div>\",\"PeriodicalId\":72251,\"journal\":{\"name\":\"Applications in engineering science\",\"volume\":\"12 \",\"pages\":\"Article 100122\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2022-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2666496822000383/pdfft?md5=c1e3155cc2330b935b9fcb96b6d4907f&pid=1-s2.0-S2666496822000383-main.pdf\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applications in engineering science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666496822000383\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applications in engineering science","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666496822000383","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 1

摘要

lvad已经在临床上使用了半个世纪,并且已经发展了至少三代,产生了紧凑,耐用,强大的泵,可以提供超过身体休息需要的血液流量。这样,这些装置已经成为终末期心力衰竭患者移植的最佳选择。也就是说,这些泵的血液接触界面可能是导致并发症和禁忌症的原因,这些并发症和禁忌症会持续几代人。副作用风险较高的患者或双心室衰竭和其他情况的患者占25%,不适合LVAD治疗。这类患者代表临床需要非血液接触机械循环支持。直接心脏压迫装置的临床使用是有限的,并且没有可供人类使用的装置。技术挑战依然存在,但这些设备仍在继续开发并在心力衰竭的动物模型中进行测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Review of devices and clinical need for non-blood contacting mechanical circulatory support

LVADs have been in clinical use for a half-century and have advanced through at least 3 generations resulting in compact, durable, and powerful pumps that can deliver blood flow that exceeds the needs of the body at rest. In so doing, these devices have become the best alternative to transplant for patients with end-stage heart failure. That said, the blood contacting interface of these pumps is likely the cause of complications and contraindications that persist with successive generations. Patients with elevated risk for side effects or patients with biventricular failure and other conditions represent the 25% of patients that are not candidates for LVAD therapy. Such patients represent the clinical need for non-blood contacting mechanical circulatory support. The clinical use of direct cardiac compression devices is limited, and there are no devices available for human use. Technological challenges remain, yet these devices continue to be developed and tested in animal models of heart failure.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Applications in engineering science
Applications in engineering science Mechanical Engineering
CiteScore
3.60
自引率
0.00%
发文量
0
审稿时长
68 days
期刊最新文献
A filter calibration method for laser-scanned weld toe geometries Numerical simulation of open channel basaltic lava flow through topographical bends An experimental study on heat transfer using electrohydrodynamics (EHD) over a heated vertical plate. Lattice Boltzmann simulations of unsteady Bingham fluid flows Thermo-fluid performance of axially perforated multiple rectangular flow deflector-type baffle plate in an tubular heat exchanger
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1