阴极保护极化片定量评价方法

IF 1.5 4区 材料科学 Q4 MATERIALS SCIENCE, MULTIDISCIPLINARY Corrosion Engineering, Science and Technology Pub Date : 2022-07-15 DOI:10.1080/1478422X.2022.2100456
M. Attarchi
{"title":"阴极保护极化片定量评价方法","authors":"M. Attarchi","doi":"10.1080/1478422X.2022.2100456","DOIUrl":null,"url":null,"abstract":"ABSTRACT With the many advantages of instantaneous off measurement, the polarisation coupon has become increasingly popular in the true polarisation potential reading of different cathodic protection systems. As a general rule, polarisation coupons are installed close to the reference electrode to reduce the error in potential measurement. As a result, the error in the potential reading for close coupons is low. Still, the mentioned error has not been quantified due to the coupon's geometry, direction and non-linear polarisation behaviour complexity. In the present work, the IR-Drop error as a function of current density is extracted with generic calculation and simple assumptions, and the results are checked with three possible coupon-reference electrode arrangements. The proposed calculation could be used to extract the intrinsic error of polarisation coupons, regardless of their arrangement and coupon size. Moreover, it could be used to correct the measured potential and extract the true structure-to-soil potential.","PeriodicalId":10711,"journal":{"name":"Corrosion Engineering, Science and Technology","volume":"57 1","pages":"553 - 559"},"PeriodicalIF":1.5000,"publicationDate":"2022-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quantitative evaluation method for cathodic protection polarisation coupon\",\"authors\":\"M. Attarchi\",\"doi\":\"10.1080/1478422X.2022.2100456\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT With the many advantages of instantaneous off measurement, the polarisation coupon has become increasingly popular in the true polarisation potential reading of different cathodic protection systems. As a general rule, polarisation coupons are installed close to the reference electrode to reduce the error in potential measurement. As a result, the error in the potential reading for close coupons is low. Still, the mentioned error has not been quantified due to the coupon's geometry, direction and non-linear polarisation behaviour complexity. In the present work, the IR-Drop error as a function of current density is extracted with generic calculation and simple assumptions, and the results are checked with three possible coupon-reference electrode arrangements. The proposed calculation could be used to extract the intrinsic error of polarisation coupons, regardless of their arrangement and coupon size. Moreover, it could be used to correct the measured potential and extract the true structure-to-soil potential.\",\"PeriodicalId\":10711,\"journal\":{\"name\":\"Corrosion Engineering, Science and Technology\",\"volume\":\"57 1\",\"pages\":\"553 - 559\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2022-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Corrosion Engineering, Science and Technology\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.1080/1478422X.2022.2100456\",\"RegionNum\":4,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MATERIALS SCIENCE, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Corrosion Engineering, Science and Technology","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1080/1478422X.2022.2100456","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

由于具有瞬时关断测量的诸多优点,极化表在不同阴极保护系统的真实极化电位读数中越来越受欢迎。一般来说,极化板安装在参考电极附近,以减少电位测量的误差。因此,收盘息票的潜在读数误差很低。尽管如此,由于联片的几何形状、方向和非线性极化行为的复杂性,上述误差尚未量化。在本工作中,通过一般计算和简单假设提取了IR-Drop误差作为电流密度的函数,并使用三种可能的参考电极布置对结果进行了验证。所提出的计算可用于提取极化券的固有误差,而不考虑它们的排列和券的大小。此外,它还可以用于校正测量电位,提取真实的结构-土电位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Quantitative evaluation method for cathodic protection polarisation coupon
ABSTRACT With the many advantages of instantaneous off measurement, the polarisation coupon has become increasingly popular in the true polarisation potential reading of different cathodic protection systems. As a general rule, polarisation coupons are installed close to the reference electrode to reduce the error in potential measurement. As a result, the error in the potential reading for close coupons is low. Still, the mentioned error has not been quantified due to the coupon's geometry, direction and non-linear polarisation behaviour complexity. In the present work, the IR-Drop error as a function of current density is extracted with generic calculation and simple assumptions, and the results are checked with three possible coupon-reference electrode arrangements. The proposed calculation could be used to extract the intrinsic error of polarisation coupons, regardless of their arrangement and coupon size. Moreover, it could be used to correct the measured potential and extract the true structure-to-soil potential.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Corrosion Engineering, Science and Technology
Corrosion Engineering, Science and Technology 工程技术-材料科学:综合
CiteScore
3.20
自引率
5.60%
发文量
58
审稿时长
3.4 months
期刊介绍: Corrosion Engineering, Science and Technology provides broad international coverage of research and practice in corrosion processes and corrosion control. Peer-reviewed contributions address all aspects of corrosion engineering and corrosion science; there is strong emphasis on effective design and materials selection to combat corrosion and the journal carries failure case studies to further knowledge in these areas.
期刊最新文献
Vibratory polishing effects on passivity of 304L stainless steel surfaces Inhibition effect of nano-silica synergistic corrosion inhibitor on 110SSsteel in ultra-high temperature organic acidic environment An overview of progresses and challenges of electrochemically integrated multi-electrode arrays for probing localised corrosion in complex environmental conditions Effect of refrigerant absorbent combinations in the corrosion resistance of copper as structural material in absorption refrigeration systems (ARS) Cavitation erosion and corrosion-cavitation synergism behaviour of CoCrFeNiMnTi x high entropy alloy coatings prepared by laser cladding
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1