一种新的基于超分辨率快速R-CNN模型的尿液沉积物检测和分类

IF 5.3 2区 医学 Q1 ENGINEERING, BIOMEDICAL Biocybernetics and Biomedical Engineering Pub Date : 2023-01-01 DOI:10.1016/j.bbe.2022.12.001
Derya Avci , Eser Sert , Esin Dogantekin , Ozal Yildirim , Ryszard Tadeusiewicz , Pawel Plawiak
{"title":"一种新的基于超分辨率快速R-CNN模型的尿液沉积物检测和分类","authors":"Derya Avci ,&nbsp;Eser Sert ,&nbsp;Esin Dogantekin ,&nbsp;Ozal Yildirim ,&nbsp;Ryszard Tadeusiewicz ,&nbsp;Pawel Plawiak","doi":"10.1016/j.bbe.2022.12.001","DOIUrl":null,"url":null,"abstract":"<div><p>The diagnosis of urinary tract infections and kidney diseases using urine microscopy images has gained significant attention of medical community in recent years. These images are usually created by physicians’ own rule of thumb<span><span> manually. However, this manual urine sediment analysis is usually labor-intensive and time-consuming. In addition, even when physicians carefully examine an image, an erroneous cell recognition may occur due to some optical illusions. In order to achieve cell recognition in low-resolution urine microscopy images with a higher level of accuracy, a new super resolution Faster Region-based Convolutional </span>Neural Network<span><span> (Faster R-CNN) method is proposed. It aims to increase resolution in low-resolution urine microscopy images using self-similarity based single image super resolution which was used during the pre-processing. De-noising based Wiener filter and </span>Discrete Wavelet Transform (DWT) are used to de-noise high resolution images, respectively, to increase the level of accuracy for image recognition. Finally, for the feature extraction and classification stages, AlexNet, VGFG16 and VGG19 based Faster R-CNN models are used for the recognition and detection of multi-class cells. The model yielded accuracy rates are 98.6%, 96.4% and 96.2% respectively.</span></span></p></div>","PeriodicalId":55381,"journal":{"name":"Biocybernetics and Biomedical Engineering","volume":"43 1","pages":"Pages 58-68"},"PeriodicalIF":5.3000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"A new super resolution Faster R-CNN model based detection and classification of urine sediments\",\"authors\":\"Derya Avci ,&nbsp;Eser Sert ,&nbsp;Esin Dogantekin ,&nbsp;Ozal Yildirim ,&nbsp;Ryszard Tadeusiewicz ,&nbsp;Pawel Plawiak\",\"doi\":\"10.1016/j.bbe.2022.12.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The diagnosis of urinary tract infections and kidney diseases using urine microscopy images has gained significant attention of medical community in recent years. These images are usually created by physicians’ own rule of thumb<span><span> manually. However, this manual urine sediment analysis is usually labor-intensive and time-consuming. In addition, even when physicians carefully examine an image, an erroneous cell recognition may occur due to some optical illusions. In order to achieve cell recognition in low-resolution urine microscopy images with a higher level of accuracy, a new super resolution Faster Region-based Convolutional </span>Neural Network<span><span> (Faster R-CNN) method is proposed. It aims to increase resolution in low-resolution urine microscopy images using self-similarity based single image super resolution which was used during the pre-processing. De-noising based Wiener filter and </span>Discrete Wavelet Transform (DWT) are used to de-noise high resolution images, respectively, to increase the level of accuracy for image recognition. Finally, for the feature extraction and classification stages, AlexNet, VGFG16 and VGG19 based Faster R-CNN models are used for the recognition and detection of multi-class cells. The model yielded accuracy rates are 98.6%, 96.4% and 96.2% respectively.</span></span></p></div>\",\"PeriodicalId\":55381,\"journal\":{\"name\":\"Biocybernetics and Biomedical Engineering\",\"volume\":\"43 1\",\"pages\":\"Pages 58-68\"},\"PeriodicalIF\":5.3000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biocybernetics and Biomedical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0208521622001127\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biocybernetics and Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0208521622001127","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 5

摘要

近年来,利用尿液显微图像诊断尿路感染和肾脏疾病受到了医学界的广泛关注。这些图像通常是由医生自己的经验法则手动创建的。然而,这种人工尿液沉积物分析通常是劳动密集型和耗时的。此外,即使当医生仔细检查图像时,由于某些视错觉,错误的细胞识别也可能发生。为了在低分辨率尿液显微图像中实现更高精度的细胞识别,提出了一种新的超分辨率Faster基于区域的卷积神经网络(Faster R-CNN)方法。它的目的是利用预处理过程中使用的基于自相似性的单图像超分辨率来提高低分辨率尿液显微镜图像的分辨率。基于去噪的维纳滤波和离散小波变换分别对高分辨率图像进行去噪,以提高图像识别的精度。最后,在特征提取和分类阶段,使用基于AlexNet、VGFG16和VGG19的Faster R-CNN模型对多类细胞进行识别和检测。模型的准确率分别为98.6%、96.4%和96.2%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A new super resolution Faster R-CNN model based detection and classification of urine sediments

The diagnosis of urinary tract infections and kidney diseases using urine microscopy images has gained significant attention of medical community in recent years. These images are usually created by physicians’ own rule of thumb manually. However, this manual urine sediment analysis is usually labor-intensive and time-consuming. In addition, even when physicians carefully examine an image, an erroneous cell recognition may occur due to some optical illusions. In order to achieve cell recognition in low-resolution urine microscopy images with a higher level of accuracy, a new super resolution Faster Region-based Convolutional Neural Network (Faster R-CNN) method is proposed. It aims to increase resolution in low-resolution urine microscopy images using self-similarity based single image super resolution which was used during the pre-processing. De-noising based Wiener filter and Discrete Wavelet Transform (DWT) are used to de-noise high resolution images, respectively, to increase the level of accuracy for image recognition. Finally, for the feature extraction and classification stages, AlexNet, VGFG16 and VGG19 based Faster R-CNN models are used for the recognition and detection of multi-class cells. The model yielded accuracy rates are 98.6%, 96.4% and 96.2% respectively.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
16.50
自引率
6.20%
发文量
77
审稿时长
38 days
期刊介绍: Biocybernetics and Biomedical Engineering is a quarterly journal, founded in 1981, devoted to publishing the results of original, innovative and creative research investigations in the field of Biocybernetics and biomedical engineering, which bridges mathematical, physical, chemical and engineering methods and technology to analyse physiological processes in living organisms as well as to develop methods, devices and systems used in biology and medicine, mainly in medical diagnosis, monitoring systems and therapy. The Journal''s mission is to advance scientific discovery into new or improved standards of care, and promotion a wide-ranging exchange between science and its application to humans.
期刊最新文献
Automating synaptic plasticity analysis: A deep learning approach to segmenting hippocampal field potential signal Probabilistic and explainable modeling of Phase–Phase Cross-Frequency Coupling patterns in EEG. Application to dyslexia diagnosis Skin cancer diagnosis using NIR spectroscopy data of skin lesions in vivo using machine learning algorithms Profiled delivery of bicarbonate during weekly cycle of hemodialysis Lightweight beat score map method for electrocardiogram-based arrhythmia classification
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1