选择性剖宫产硬膜穿刺针(18G)意外穿刺1例报告

Omar Rajab, S. Kanawati, M. Barada, Z. Naja, L. Sinno
{"title":"选择性剖宫产硬膜穿刺针(18G)意外穿刺1例报告","authors":"Omar Rajab, S. Kanawati, M. Barada, Z. Naja, L. Sinno","doi":"10.4103/joacc.joacc_59_21","DOIUrl":null,"url":null,"abstract":"A 23-year-old parturient with a body mass index of 20.8 kg/m2 at term was admitted for elective caesarean section. Spinal anaesthesia was done using a 27-G pencil-point needle without an introducer guide, with the usage of a separate 18-G introducer needle. After the introduction of the introducer at the level of L4–L5, accidental free flow of cerebrospinal fluid (CSF) was seen. The introducer was withdrawn and inserted at the level of L3–L4, followed by the spinal needle. CSF backflow was seen; an anaesthetic mixture was given. Block was successful and caesarean section was done with no intraoperative complications.","PeriodicalId":16611,"journal":{"name":"Journal of Obstetric Anaesthesia and Critical Care","volume":" ","pages":""},"PeriodicalIF":0.2000,"publicationDate":"2021-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accidental Dural Puncture With An Introducer Needle (18 G) For Elective Caesarean Section: A case report\",\"authors\":\"Omar Rajab, S. Kanawati, M. Barada, Z. Naja, L. Sinno\",\"doi\":\"10.4103/joacc.joacc_59_21\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A 23-year-old parturient with a body mass index of 20.8 kg/m2 at term was admitted for elective caesarean section. Spinal anaesthesia was done using a 27-G pencil-point needle without an introducer guide, with the usage of a separate 18-G introducer needle. After the introduction of the introducer at the level of L4–L5, accidental free flow of cerebrospinal fluid (CSF) was seen. The introducer was withdrawn and inserted at the level of L3–L4, followed by the spinal needle. CSF backflow was seen; an anaesthetic mixture was given. Block was successful and caesarean section was done with no intraoperative complications.\",\"PeriodicalId\":16611,\"journal\":{\"name\":\"Journal of Obstetric Anaesthesia and Critical Care\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2021-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Obstetric Anaesthesia and Critical Care\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/joacc.joacc_59_21\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Obstetric Anaesthesia and Critical Care","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/joacc.joacc_59_21","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

23岁产妇足月体重指数20.8 kg/m2行择期剖宫产。脊髓麻醉使用一根27-G铅笔尖针,不带引入针,使用一根单独的18-G引入针。在L4-L5水平引入引入器后,可见脑脊液(CSF)意外自由流动。取出引入器并在L3-L4水平插入,然后是脊髓针。可见脑脊液回流;给了麻醉药混合物。阻滞成功,剖宫产,无术中并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Accidental Dural Puncture With An Introducer Needle (18 G) For Elective Caesarean Section: A case report
A 23-year-old parturient with a body mass index of 20.8 kg/m2 at term was admitted for elective caesarean section. Spinal anaesthesia was done using a 27-G pencil-point needle without an introducer guide, with the usage of a separate 18-G introducer needle. After the introduction of the introducer at the level of L4–L5, accidental free flow of cerebrospinal fluid (CSF) was seen. The introducer was withdrawn and inserted at the level of L3–L4, followed by the spinal needle. CSF backflow was seen; an anaesthetic mixture was given. Block was successful and caesarean section was done with no intraoperative complications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
37
审稿时长
29 weeks
期刊最新文献
To study maternal hypotension, side-effects and fetal acid-base balance during cesarean delivery under spinal anesthesia using prophylactic infusion doses of 25 and 50 μg/Min phenylephrine Takotsubo cardiomyopathy in pregnancy: A focused review Comparative evaluation of two doses of phenylephrine infusion to prevent intra-operative nausea and vomiting during elective obstetric spinal anesthesia Carbetocin: Are we ready for a paradigm shift? Evaluation of perfusion index as a screening tool for prediction of hypotension and shivering in cesarean section
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1